C Pauli1, U Fakler, T Genz, M Hennig, H-P Lorenz, J Hess. 1. Department of Paediatric Cardiology and Congenital Heart Disease, Deutsches Herzzentrum München, Technische Universität München, Lazarettstrasse 36, 80636 Munich, Germany. pauli@dhm.mhn.de
Abstract
OBJECTIVE: To show the equivalence of the transpulmonary thermodilution method to the direct Fick principle in children. DESIGN: Prospective single-centre study. SETTING: A 16-bed paediatric cardiac ICU and a cardiac catheterisation laboratory at an university affiliated centre for paediatric cardiology and congenital heart disease. PATIENTS: We consecutively investigated 18 patients (mean age 12.1 +/- 6.4 years) during cardiac catheterisation and after corrective cardiac operation. METHODS AND RESULTS: We prospectively defined limits of equivalence for cardiac index (CI) for both methods of +/- 0.25 l/min x m(2). We measured oxygen consumption for determination of CI by Fick as the clinical "gold standard" and performed a set of three transpulmonary thermodilution measurements. The mean CI(Fick) was 2.88 +/- 1.07 l/min x m(2) (range 1.10-4.62 l/min x m(2)) and CI(TPID)was 2.85 +/- 1.03 l/min x m(2)(range 1.02-4.49 l/min x m(2)). The mean difference between CI(Fick) and CI(TPID)was 0.030 +/- 0.168 l/min x m(2), and limits of agreement -0.306 to 0.366 l/min x m(2)(90% confidence interval -0.040 to 0.099 l/min x m(2)). The regression equation was : CI(Fick)=1.0244 x CI(TPID)-0.040, r(2) = 0.976, P < 0.0001. The intraclass coefficient of reliability for three repeated measurements of CI(TPID) was 0.97, the corresponding lower limit of the 95% confidence interval was 0.94. CONCLUSION: We demonstrated the equivalence of CI measurement by transpulmonary thermodilution and the Fick principle in children. This new method may improve hemodynamic monitoring and management in seriously ill children.
OBJECTIVE: To show the equivalence of the transpulmonary thermodilution method to the direct Fick principle in children. DESIGN: Prospective single-centre study. SETTING: A 16-bed paediatric cardiac ICU and a cardiac catheterisation laboratory at an university affiliated centre for paediatric cardiology and congenital heart disease. PATIENTS: We consecutively investigated 18 patients (mean age 12.1 +/- 6.4 years) during cardiac catheterisation and after corrective cardiac operation. METHODS AND RESULTS: We prospectively defined limits of equivalence for cardiac index (CI) for both methods of +/- 0.25 l/min x m(2). We measured oxygen consumption for determination of CI by Fick as the clinical "gold standard" and performed a set of three transpulmonary thermodilution measurements. The mean CI(Fick) was 2.88 +/- 1.07 l/min x m(2) (range 1.10-4.62 l/min x m(2)) and CI(TPID)was 2.85 +/- 1.03 l/min x m(2)(range 1.02-4.49 l/min x m(2)). The mean difference between CI(Fick) and CI(TPID)was 0.030 +/- 0.168 l/min x m(2), and limits of agreement -0.306 to 0.366 l/min x m(2)(90% confidence interval -0.040 to 0.099 l/min x m(2)). The regression equation was : CI(Fick)=1.0244 x CI(TPID)-0.040, r(2) = 0.976, P < 0.0001. The intraclass coefficient of reliability for three repeated measurements of CI(TPID) was 0.97, the corresponding lower limit of the 95% confidence interval was 0.94. CONCLUSION: We demonstrated the equivalence of CI measurement by transpulmonary thermodilution and the Fick principle in children. This new method may improve hemodynamic monitoring and management in seriously ill children.
Authors: Riccardo Lubrano; Marco Elli; Francesca Stoppa; Mario Di Traglia; Matteo Di Nardo; Daniela Perrotta; Piero David; Sara Paoli; Corrado Cecchetti Journal: Childs Nerv Syst Date: 2015-04-14 Impact factor: 1.475
Authors: Jonathan R Egan; Marino Festa; Andrew D Cole; Graham R Nunn; Jonathan Gillis; David S Winlaw Journal: Intensive Care Med Date: 2005-02-15 Impact factor: 17.440