Evaluation of transpulmonary thermodilution as a method to measure cardiac output in anesthetized cats.

Kim E Beaulieu1, Carolyn L Kerr, Wayne N McDonell.   

Abstract

The objectives of this study were to evaluate the use of a transpulmonary thermodilution (Trans) technique for the measurement of cardiac output, and to determine the agreement between Trans and conventional thermodilution (TD) in anesthetized cats. Using each technique, cardiac output was measured in 5 mature cats (weights 2.4 to 5.6 kg) anesthetized with isoflurane. To induce different levels of cardiac output in each cat, anesthesia was maintained at > 1.5x end-tidal minimum alveolar concentration (MAC) of isoflurane, and at 1.3x end-tidal isoflurane MAC with and without administration of dobutamine. At least 2 comparisons between TD and Trans values were made at each cardiac output rate. Thirty-two of the 42 recorded comparisons were analyzed. Linear regression analysis (TD vs Trans) yielded an r(2) value of 0.83. The mean bias (TD-Trans) was -3.7 mL/kg/min with limits of agreement of -35.9 to 28.5 mL/kg/min. The concordance coefficient was 0.91. The Trans method showed good relationship and good agreement with TD in anesthetized cats. The Trans method is a relatively noninvasive, practical, and safe method to measure cardiac output in anesthetized cats.

Entities:  

Mesh:

Year:  2009        PMID: 19337388      PMCID: PMC2613590     

Source DB:  PubMed          Journal:  Can J Vet Res        ISSN: 0830-9000            Impact factor:   1.310


  22 in total

Review 1.  Pulmonary artery blood temperature and the measurement of cardiac output by thermodilution.

Authors:  S F Moise; C J Sinclair; D H T Scott
Journal:  Anaesthesia       Date:  2002-06       Impact factor: 6.955

2.  Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique.

Authors:  G Della Rocca; M G Costa; L Pompei; C Coccia; P Pietropaoli
Journal:  Br J Anaesth       Date:  2002-03       Impact factor: 9.166

3.  A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques.

Authors:  L A Critchley; J A Critchley
Journal:  J Clin Monit Comput       Date:  1999-02       Impact factor: 2.502

4.  Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmonary indicator dilution in critically ill neonates and infants.

Authors:  Holger Schiffmann; Bernhard Erdlenbruch; Dominique Singer; Sybille Singer; Egbert Herting; Andreas Hoeft; Wolfgang Buhre
Journal:  J Cardiothorac Vasc Anesth       Date:  2002-10       Impact factor: 2.628

5.  Isoflurane potency in the dog and cat.

Authors:  E P Steffey; D Howland
Journal:  Am J Vet Res       Date:  1977-11       Impact factor: 1.156

6.  Cardiac output in the conscious rabbit: an analysis of the thermodilution technique.

Authors:  D J Warren; J G Ledingham
Journal:  J Appl Physiol       Date:  1974-02       Impact factor: 3.531

7.  Thermodilution cardiac output measurement. Effects of the respiratory cycle on its reproducibility.

Authors:  J H Stevens; T A Raffin; F G Mihm; M H Rosenthal; C W Stetz
Journal:  JAMA       Date:  1985-04-19       Impact factor: 56.272

8.  Cardiac output measurements with thermodilution and radioactive microspheres. A comparative study in cats.

Authors:  S Arvidsson; D Bergqvist; U Haglund; B Lindblad
Journal:  Scand J Clin Lab Invest       Date:  1983-11       Impact factor: 1.713

9.  Reliability of the thermodilution method in the determination of cardiac output in clinical practice.

Authors:  C W Stetz; R G Miller; G E Kelly; T A Raffin
Journal:  Am Rev Respir Dis       Date:  1982-12

10.  Slowing of heart rate during cardiac output measurement by thermodilution.

Authors:  T Nishikawa; S Dohi
Journal:  Anesthesiology       Date:  1982-12       Impact factor: 7.892

View more
  4 in total

Review 1.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

2.  Trending ability and limitations of transpulmonary thermodilution and pulse contour cardiac output measurement in cats as a model for pediatric patients.

Authors:  Annette P N Kutter; Rima N Bektas; Christoph K Hofer; M Paula Larenza Menzies; Regula Bettschart-Wolfensberger
Journal:  J Clin Monit Comput       Date:  2014-09-17       Impact factor: 2.502

3.  Comparison of Transpulmonary Thermodilution and Calibrated Pulse Contour Analysis with Pulmonary Artery Thermodilution Cardiac Output Measurements in Anesthetized Dogs.

Authors:  N A Garofalo; F J Teixeira-Neto; J C Rodrigues; S A Cerejo; A J A Aguiar; D R Becerra-Velásquez
Journal:  J Vet Intern Med       Date:  2016-05-30       Impact factor: 3.333

4.  Anesthesia-Associated Relative Hypovolemia: Mechanisms, Monitoring, and Treatment Considerations.

Authors:  Jessica Noel-Morgan; William W Muir
Journal:  Front Vet Sci       Date:  2018-03-16