Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose.

Eike Hein1, Patrik Rogalla, Randolph Klingebiel, Bernd Hamm.   

Abstract

The purpose of the study was to assess the effect of lens protection on image quality and radiation dose to the eye lenses in CT of the paranasal sinuses. In 127 patients referred to rule out sinusitis, an axial spiral CT with a lens protection placed on the patients eyes was obtained (1.5/2/1, 50 mAs, 120 kV). Coronal views were reconstructed at 5-mm interval. To quantify a subjective impression of image quality, three regions of interest within the eyeball were plotted along a line perpendicular to the protection at 2, 5, and 9 mm beneath skin level on the axial images. Additionally, dose reduction of a bismuth-containing latex shield was measured using a film-dosimetry technique. The average eyeball density was 17.97 HU (SD 3.7 HU). The relative increase in CT density was 180.6 (17.7), 103.3 (11.7), and 53.6 HU (9.2), respectively. There was no diagnostic information loss on axial and coronal views observed. Artifacts were practically invisible on images viewed in a bone window/level setting. The use of the shield reduced skin radiation from 7.5 to 4.5 mGy. The utilization of a radioprotection to the eye lenses in paranasal CT is a suitable and effective means of reducing skin radiation by 40%.

Entities:  

Mesh:

Year:  2002        PMID: 12111059     DOI: 10.1007/s00330-001-1279-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  24 in total

1.  Proposal of a CT scoring system of the paranasal sinuses in diagnosing cystic fibrosis.

Authors:  H B Eggesbø; S Søvik; S Dølvik; K Eiklid; F Kolmannskog
Journal:  Eur Radiol       Date:  2003-04-05       Impact factor: 5.315

2.  Efficacy of breast shielding during CT of the head.

Authors:  Z Brnić; B Vekić; A Hebrang; P Anić
Journal:  Eur Radiol       Date:  2003-06-25       Impact factor: 5.315

3.  [CT and MR imaging of the facial nerve].

Authors:  H P Burmeister; P A T Baltzer; C M Klingner; M Pantel; W A Kaiser
Journal:  HNO       Date:  2010-05       Impact factor: 1.284

4.  Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality.

Authors:  J Geleijns; M Salvadó Artells; W J H Veldkamp; M López Tortosa; A Calzado Cantera
Journal:  Eur Radiol       Date:  2006-04-08       Impact factor: 5.315

Review 5.  Radiological imaging of inflammatory lesions in the nasal cavity and paranasal sinuses.

Authors:  H B Eggesbø
Journal:  Eur Radiol       Date:  2006-01-04       Impact factor: 5.315

Review 6.  [Imaging in inflammatory diseases of the paranasal sinuses].

Authors:  M G Mack; A May; S Bisdas; M Baghi; T J Vogl
Journal:  Radiologe       Date:  2007-07       Impact factor: 0.635

7.  CT dose and image quality in the last three scanner generations.

Authors:  Andreas Christe; Johannes Heverhagen; Christoph Ozdoba; Christian Weisstanner; Stefan Ulzheimer; Lukas Ebner
Journal:  World J Radiol       Date:  2013-11-28

8.  Cone beam CT: a current overview of devices.

Authors:  A Nemtoi; C Czink; D Haba; A Gahleitner
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

9.  Low-Dose CT of the Paranasal Sinuses: Minimizing X-Ray Exposure with Spectral Shaping.

Authors:  Wolfgang Wuest; Matthias May; Marc Saake; Michael Brand; Michael Uder; Michael Lell
Journal:  Eur Radiol       Date:  2016-02-24       Impact factor: 5.315

10.  Cone-beam computed tomography: a new low dose, high resolution imaging technique of the wrist, presentation of three cases with technique.

Authors:  Jens De Cock; Koen Mermuys; Jean Goubau; Simon Van Petegem; Brecht Houthoofd; Jan W Casselman
Journal:  Skeletal Radiol       Date:  2011-05-21       Impact factor: 2.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.