[Perforation of the aorta after percutaneous closure of an atrial septal defect with an Amplatz prosthesis, presenting with acute severe hemolysis].

Y Aggoun1, B Gallet, P Acar, M Pulik, D Czitrom, A Lagier, F Laborde.   

Abstract

We report a case of aortic perforation three weeks after transcatheter occlusion of an atrial septal defect (ASD) by an Amplatzer device. Revealed by acute hemolysis, this complication needed an emergency surgical operation. The fistula between the no coronary Valsalva sinus of the aorta and the left atrium was repaired. The ASD was closed by patch. This serious accident should consider a short antero-superior rim as a risk factor for aortic perforation in transcatheter closure for ASD.

Entities:  

Mesh:

Year:  2002        PMID: 12085748

Source DB:  PubMed          Journal:  Arch Mal Coeur Vaiss        ISSN: 0003-9683


  8 in total

1.  Amplatzer septal occluder closure of secundum atrial septal defects in the presence of persistent left superior vena cava to coronary sinus.

Authors:  K M Carlson; T A Johnston; T K Jones; R G Grifka
Journal:  Pediatr Cardiol       Date:  2004 Nov-Dec       Impact factor: 1.655

Review 2.  Atrial septum defect closure device in a beating heart, from the perspective of a researcher in artificial organs.

Authors:  Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2012-06-23       Impact factor: 1.731

3.  Initial Experience with the Nit-Occlud ASD-R: Short-Term Results.

Authors:  Mustafa Orhan Bulut; Ilker Kemal Yucel; Mehmet Kucuk; Sevket Balli; Evic Zeynep Basar; Ahmet Celebi
Journal:  Pediatr Cardiol       Date:  2016-06-09       Impact factor: 1.655

4.  Delayed aorto-right atrial fistula following percutaneous closure of atrial septal defect.

Authors:  M Bashir; H Abudhaise; H Mustafa; M Fok; A Bashir; I Hammoud; J Mascaro
Journal:  Ann R Coll Surg Engl       Date:  2014-07       Impact factor: 1.891

Review 5.  Challenges encountered during closure of atrial septal defects.

Authors:  W Knirsch; A Dodge-Khatami; E Valsangiacomo-Buechel; M Weiss; F Berger
Journal:  Pediatr Cardiol       Date:  2005 Mar-Apr       Impact factor: 1.655

6.  ASD device closure in pediatrics: 3-Dimensional transthoracic echocardiography perspective.

Authors:  Sonia A El-Saiedi; Hala M Agha; Mohamed F Shaltoot; Hayat H Nassar; Amal M El Sisi; Wael A Attia; Yasser M Sedky
Journal:  J Saudi Heart Assoc       Date:  2017-11-26

Review 7.  Role of Echocardiography in the Diagnosis and Interventional Management of Atrial Septal Defects.

Authors:  P Syamasundar Rao
Journal:  Diagnostics (Basel)       Date:  2022-06-18

Review 8.  Device closure of secundum atrial septal defect's and the risk of cardiac erosion.

Authors:  J D R Thomson; S A Qureshi
Journal:  Echo Res Pract       Date:  2015-09-02