Literature DB >> 27278631

Initial Experience with the Nit-Occlud ASD-R: Short-Term Results.

Mustafa Orhan Bulut1, Ilker Kemal Yucel1, Mehmet Kucuk1, Sevket Balli2, Evic Zeynep Basar1, Ahmet Celebi1.   

Abstract

We aim to assess the safety, feasibility and efficacy of the new Nit-Occlud ASD-R (NOASD-R) device. From 2014 to 2015, transcatheter closure of atrial septal defect (ASD) using the NOASD-R was performed in 30 consecutive patients. The standard deployment technique as the left upper pulmonary vein approach was used in 25 patients. Right upper pulmonary vein approach was required in five. The median age was 6 years (range 3.5-60 years), and median weight was 21.5 kg (14-79 kg). Implantation was successful in all patients. The median size of devices was 16 mm (12.0-26.0 mm). The mean device size/2D defect diameter ratio was 1.26 ± 0.09 (1.12-1.40). The mean device size/color flow diameter ratio was 1.07 ± 0.06 (range 1.0-1.22). Releasing problem was encountered in three patients. A device-related erosion on the day after the closure was observed in one patient. No further device-related complication (erosion, embolization or dislodgement of the device) was encountered in a median follow-up period of 10 months (range 2-14 months). Complete occlusion has occurred in all at follow-up. NOASD-R is a feasible and effective device for use in the transcatheter occlusion of moderate to large secundum ASDs in selected patients. The occurrence of the erosion on the right atrial roof may be due to the high localization of the device and the larger size of the right disk.

Entities:  

Keywords:  Atrial septal defect closure; Nit-Occlud ASD-R device; Outcomes

Mesh:

Year:  2016        PMID: 27278631     DOI: 10.1007/s00246-016-1426-3

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  18 in total

1.  [Perforation of the aorta after percutaneous closure of an atrial septal defect with an Amplatz prosthesis, presenting with acute severe hemolysis].

Authors:  Y Aggoun; B Gallet; P Acar; M Pulik; D Czitrom; A Lagier; F Laborde
Journal:  Arch Mal Coeur Vaiss       Date:  2002-05

Review 2.  Erosions, erosions, and erosions! Device closure of atrial septal defects: how safe is safe?

Authors:  Karim Diab; Damien Kenny; Ziyad M Hijazi
Journal:  Catheter Cardiovasc Interv       Date:  2012-08-01       Impact factor: 2.692

3.  Transthoracic echocardiographic guidance during transcatheter closure of atrial septal defects in children and adults.

Authors:  Abdullah Erdem; Turkay Sarıtas; Cenap Zeybek; Ilker Kemal Yucel; Nurdan Erol; Halil Demır; Ender Odemıs; Yalim Yalcın; Ahmet Celebı
Journal:  Int J Cardiovasc Imaging       Date:  2011-08-11       Impact factor: 2.357

4.  Complications of transcatheter closure of atrial septal defects.

Authors:  M S Spence; S A Qureshi
Journal:  Heart       Date:  2005-08-23       Impact factor: 5.994

5.  Confidence in ASD occluder devices is eroding.

Authors:  Richard A Lange
Journal:  Catheter Cardiovasc Interv       Date:  2012-08-01       Impact factor: 2.692

6.  Late erosion of Amplatzer septal occluder device resulting in cardiac tamponade.

Authors:  Vakhtang Tchantchaleishvili; Amber L Melvin; Frederick S Ling; Peter A Knight
Journal:  Interact Cardiovasc Thorac Surg       Date:  2014-09-01

7.  Optimal septum alignment of the Figulla Flex occluder to the atrial septum in patients with secundum atrial septal defects.

Authors:  Nikolaus A Haas; Christoph M Happel; Dagmar B Soetemann; Andreas Hanslik; Axel Moysich; Deniz Kececioglu; Kai Thorsten Laser
Journal:  EuroIntervention       Date:  2016-02       Impact factor: 6.534

8.  Initial experience in Brazil with the Helex septal occluder for percutaneous occlusion of atrial septal defects.

Authors:  Carlos A C Pedra; Simone F Pedra; César A Esteves; Francisco Chamiê; Sérgio Ramos; Sérgio C Pontes; João Carlos Tress; Sérgio L N Braga; Larry A Latson; Valmir F Fontes
Journal:  Arq Bras Cardiol       Date:  2003-12-01       Impact factor: 2.000

9.  Catheter closure of atrial septal defects using the Cocoon septal occluder: preliminary results of a European multicenter study.

Authors:  Basil D Thanopoulos; Luigi Biasco; Petros Dardas; Ole De Backer; Panayiotis Avraamides; Dan Deleanou; Vlassis Ninios; Petros P Mavrommatis; Lars Soendergaard
Journal:  Int J Cardiol       Date:  2014-10-11       Impact factor: 4.164

10.  Transcatheter atrial septal defect closure using occlutech figulla device: a two-center experience.

Authors:  Hojat Mortezaeian; Keyhan Sayadpour Zanjani; Elaheh Malakan Rad
Journal:  J Tehran Heart Cent       Date:  2013-10-28
View more
  2 in total

Review 1.  An Up-to-Date Narrative Review on Congenital Heart Disease Percutaneous Treatment in Children Using Contemporary Devices.

Authors:  Stefana Maria Moisa; Alexandru Burlacu; Crischentian Brinza; Elena Țarcă; Lăcrămioara Ionela Butnariu; Laura Mihaela Trandafir
Journal:  Diagnostics (Basel)       Date:  2022-05-10

Review 2.  Transcatheter closure of atrial septal defect: principles and available devices.

Authors:  Se Yong Jung; Jae Young Choi
Journal:  J Thorac Dis       Date:  2018-09       Impact factor: 2.895

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.