Literature DB >> 12071615

Objective comparison of quantitative imaging modalities without the use of a gold standard.

John W Hoppin1, Matthew A Kupinski, George A Kastis, Eric Clarkson, Harrison H Barrett.   

Abstract

Imaging is often used for the purpose of estimating the value of some parameter of interest. For example, a cardiologist may measure the ejection fraction (EF) of the heart in order to know how much blood is being pumped out of the heart on each stroke. In clinical practice, however, it is difficult to evaluate an estimation method because the gold standard is not known, e.g., a cardiologist does not know the true EF of a patient. Thus, researchers have often evaluated an estimation method by plotting its results against the results of another (more accepted) estimation method, which amounts to using one set of estimates as the pseudogold standard. In this paper, we present a maximum-likelihood approach for evaluating and comparing different estimation methods without the use of a gold standard with specific emphasis on the problem of evaluating EF estimation methods. Results of numerous simulation studies will be presented and indicate that the method can precisely and accurately estimate the parameters of a regression line without a gold standard, i.e., without the x axis.

Entities:  

Mesh:

Year:  2002        PMID: 12071615      PMCID: PMC3150581          DOI: 10.1109/TMI.2002.1009380

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  18 in total

1.  Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: comparison of two methods.

Authors:  T L Faber; J P Vansant; R I Pettigrew; J R Galt; M Blais; G Chatzimavroudis; C D Cooke; R D Folks; S M Waldrop; E Gurtler-Krawczynska; M D Wittry; E V Garcia
Journal:  J Nucl Cardiol       Date:  2001 Nov-Dec       Impact factor: 5.952

2.  Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable?

Authors:  N G Bellenger; M I Burgess; S G Ray; A Lahiri; A J Coats; J G Cleland; D J Pennell
Journal:  Eur Heart J       Date:  2000-08       Impact factor: 29.983

Review 3.  Estimation of test error rates, disease prevalence and relative risk from misclassified data: a review.

Authors:  S D Walter; L M Irwig
Journal:  J Clin Epidemiol       Date:  1988       Impact factor: 6.437

4.  Receiver operator characteristic (ROC) analysis without truth.

Authors:  R M Henkelman; I Kay; M J Bronskill
Journal:  Med Decis Making       Date:  1990 Jan-Mar       Impact factor: 2.583

5.  Use and interpretation of common statistical tests in method-comparison studies.

Authors:  J O Westgard; M R Hunt
Journal:  Clin Chem       Date:  1973-01       Impact factor: 8.327

6.  Prediction of myocardial infarction versus cardiac death by gated myocardial perfusion SPECT: risk stratification by the amount of stress-induced ischemia and the poststress ejection fraction.

Authors:  T Sharir; G Germano; X Kang; H C Lewin; R Miranda; I Cohen; R D Agafitei; J D Friedman; D S Berman
Journal:  J Nucl Med       Date:  2001-06       Impact factor: 10.057

7.  Left ventricular ejection fraction and volumes from gated blood pool tomography: comparison between two automatic algorithms that work in three-dimensional space.

Authors:  C Vanhove; P R Franken
Journal:  J Nucl Cardiol       Date:  2001 Jul-Aug       Impact factor: 5.952

8.  Gated myocardial perfusion tomography for the assessment of left ventricular function and volumes: comparison with echocardiography.

Authors:  E Cwajg; J Cwajg; Z X He; W S Hwang; F Keng; S F Nagueh; M S Verani
Journal:  J Nucl Med       Date:  1999-11       Impact factor: 10.057

9.  Left ventricular volumes, ejection fraction, and regional wall motion calculated with gated technetium-99m tetrofosmin SPECT in reperfused acute myocardial infarction at super-acute phase: comparison with left ventriculography.

Authors:  M Abe; Y Kazatani; H Fukuda; H Tatsuno; H Habara; H Shinbata
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

10.  Estimation in medical imaging without a gold standard.

Authors:  Matthew A Kupinski; John W Hoppin; Eric Clarkson; Harrison H Barrett; George A Kastis
Journal:  Acad Radiol       Date:  2002-03       Impact factor: 3.173

View more
  16 in total

1.  Comparison of different segmentation approaches without using gold standard. Application to the estimation of the left ventricle ejection fraction from cardiac cine MRI sequences.

Authors:  Jessica Lebenberg; Irène Buvat; Mireille Garreau; Christopher Casta; Constantin Constantinidès; Jean Cousty; Alexandre Cochet; Stéphanie Jehan-Besson; Christophe Tilmant; Muriel Lefort; Elodie Roullot; Laurent Najman; Laurent Sarry; Patrick Clarysse; Alain de Cesare; Alain Lalande; Frédérique Frouin
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

Review 2.  PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques.

Authors:  Habib Zaidi; Issam El Naqa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-03-25       Impact factor: 9.236

3.  Evaluating Estimation Techniques in Medical Imaging Without a Gold Standard: Experimental Validation.

Authors:  John W Hoppin; Matthew A Kupinski; Donald W Wilson; Todd Peterson; Benjamin Gershman; George Kastis; Eric Clarkson; Lars Furenlid; Harrison H Barrett
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2003-02-15

4.  Metrology Standards for Quantitative Imaging Biomarkers.

Authors:  Daniel C Sullivan; Nancy A Obuchowski; Larry G Kessler; David L Raunig; Constantine Gatsonis; Erich P Huang; Marina Kondratovich; Lisa M McShane; Anthony P Reeves; Daniel P Barboriak; Alexander R Guimaraes; Richard L Wahl
Journal:  Radiology       Date:  2015-08-12       Impact factor: 11.105

5.  Bayesian framework inspired no-reference region-of-interest quality measure for brain MRI images.

Authors:  Michael Osadebey; Marius Pedersen; Douglas Arnold; Katrina Wendel-Mitoraj
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-13

6.  No-gold-standard evaluation of image-acquisition methods using patient data.

Authors:  Abhinav K Jha; Eric Frey
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-10

7.  Perfusion-weighted MR imaging studies in brain hypervascular diseases: comparison of arterial input function extractions for perfusion measurement.

Authors:  D Ducreux; I Buvat; J F Meder; D Mikulis; A Crawley; D Fredy; K TerBrugge; P Lasjaunias; J Bittoun
Journal:  AJNR Am J Neuroradiol       Date:  2006-05       Impact factor: 3.825

8.  A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods.

Authors:  Abhinav K Jha; Brian Caffo; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-03-16       Impact factor: 3.609

9.  Objective evaluation of reconstruction methods for quantitative SPECT imaging in the absence of ground truth.

Authors:  Abhinav K Jha; Na Song; Brian Caffo; Eric C Frey
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-04-13

10.  Comparing cardiac ejection fraction estimation algorithms without a gold standard.

Authors:  Matthew A Kupinski; John W Hoppin; Joshua Krasnow; Seth Dahlberg; Jeffrey A Leppo; Michael A King; Eric Clarkson; Harrison H Barrett
Journal:  Acad Radiol       Date:  2006-03       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.