In vitro measurement accuracy of an electronic apex locator in teeth with simulated apical root resorption.

Fernando Goldberg1, Ana C De Silvio, Susana Manfré, Natalia Nastri.   

Abstract

The purpose of this in vitro study was to evaluate the accuracy of Root ZX apex locator to determine the working length in teeth with simulated apical root resorption. Fifty extracted, single-rooted, human teeth with mature apices were used in this study. An irregular cavity defect was drilled at the apex of each tooth simulating an apical root resorption. Three operators used the Root ZX to measure the working lengths, comparing the electronic readings with the direct visual measurements. The Root ZX was 62.7%, 94.0%, and 100.0% accurate to within 0.5 mm, 1 mm, and 1.5 mm of the direct visual measurements, respectively. Statistically significant differences were observed between operator A and B and A and C (p < 0.01), but no significant differences were detected between operator B and C (p > 0.01).

Entities:  

Mesh:

Year:  2002        PMID: 12067130     DOI: 10.1097/00004770-200206000-00011

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  12 in total

1.  Clinical evaluation of Root ZX II electronic apex locator in primary teeth.

Authors:  S Saritha; K S Uloopi; C Vinay; R Chandra Sekhar; V V Rao
Journal:  Eur Arch Paediatr Dent       Date:  2012-02

2.  The influence of periapical lesions on the repeatability of two electronic apex locators in vivo.

Authors:  Carlos G Adorno; Sandra M Solaeche; Ileana E Ferreira; Andrea Pedrozo; Patricia M Escobar; Vicente R Fretes
Journal:  Clin Oral Investig       Date:  2021-02-13       Impact factor: 3.573

3.  Accuracy of an Electronic Apex Locator for Working Length Determination in Primary Anterior Teeth.

Authors:  Zahra Bahrololoomi; Ali Asghar Soleymani; Jalil Modaresi; Mahsa Imanian; Malihe Lotfian
Journal:  J Dent (Tehran)       Date:  2015-04

4.  Calcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locator.

Authors:  Emel Uzunoglu; Ayhan Eymirli; Mehmet Özgür Uyanik; Semra Çalt; Emre Nagas
Journal:  Restor Dent Endod       Date:  2014-11-05

5.  In vitro evaluation of Root ZX and Raypex 6 in teeth with different apical diameters.

Authors:  Ugur Aydin; Emrah Karataslioglu; Fatih Aksoy; Cihan Yildirim
Journal:  J Conserv Dent       Date:  2015 Jan-Feb

6.  An In Vitro Comparison of Propex II Apex Locator to Standard Radiographic Method.

Authors:  Kalyan Vinayak Chakravarthy Pishipati
Journal:  Iran Endod J       Date:  2013-08-01

Review 7.  Comparative Evaluation of Electronic Apex Locators and Radiovisiography for Working Length Determination in Primary Teeth in vivo.

Authors:  Ahsan Abdullah; Neerja Singh; Monika S Rathore; Shobha Tandon; Balakrishnan Rajkumar
Journal:  Int J Clin Pediatr Dent       Date:  2016-06-15

8.  Comparative evaluation of the accuracy of two electronic apex locators in determining the working length in teeth with simulated apical root resorption: An in vitro study.

Authors:  Vidya Saraswathi; Archit Kedia; Tina Puthen Purayil; Vasudev Ballal; Aakriti Saini
Journal:  J Conserv Dent       Date:  2016 Sep-Oct

9.  In vitro Evaluation of the Accuracy of the Root Zx in the Presence of Naocl 2.5% and Chlorhexidine 0.2.

Authors:  Marjan Bolbolian; Siamak Golchin; Seyedmatin Faegh
Journal:  J Clin Exp Dent       Date:  2018-11-01

10.  Comparison of Accuracy in Determining the Root Canal Working Length by Using Two Generations of Apex Locators - An In Vitro Study.

Authors:  Kapil Golvankar; Mohammed Abdul Kader; Abhilash Abdul Latheef; Ahamed Babiker Mohammed Ali; Shahabe Saquib Abullais; Mohammed Sibagathullah
Journal:  Open Access Maced J Med Sci       Date:  2019-09-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.