Data acquisition in PET imaging.

Frederic H Fahey1.   

Abstract

Data acquisition is substantially different in PET than it is in planar nuclear medicine and SPECT. There is an entirely different set of definitions and considerations. The objective of this paper is to provide the reader with the terminology and understanding of how PET data are acquired and organized as well as the issues involved in choosing one approach over another. Sinograms and projection views will be presented as methods of storing and viewing raw PET data. Different approaches to increase axial sampling while maintaining a sufficient number of counts for each reconstructed slice are discussed, as well as the use of sinogram compression or "mashing" to reduce the storage requirements of raw PET data. The differences between 2-dimensional (2D) and 3-dimensional (3D) PET and how storage of raw 3D data may differ from that of 2D data are described. The concept of "Michelograms" as a means of displaying the nature of the axial sampling in both 2D and 3D PET is discussed. After reading this paper, the reader will be able to describe 2 methods used to store and display raw PET data and compare them with methods used in SPECT. The reader will be able to define the terms "span" and "maximum ring difference" and describe how they relate to the axial sampling in 2D and 3D PET. The reader will also be able to list 3 ways in which 3D PET differs from 2D PET.

Mesh:

Substances:

Year:  2002        PMID: 12055275

Source DB:  PubMed          Journal:  J Nucl Med Technol        ISSN: 0091-4916


  13 in total

1.  On the significance of defective block detectors in clinical (18)F-FDG PET/CT imaging.

Authors:  Esmat Elhami; Maryam Samiee; Sandor Demeter; William D Leslie; Andrew L Goertzen
Journal:  Mol Imaging Biol       Date:  2011-04       Impact factor: 3.488

2.  Performance evaluation of the Philips MOSAIC small animal PET scanner.

Authors:  Marc C Huisman; Sybille Reder; Axel W Weber; Sibylle I Ziegler; Markus Schwaiger
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-11-22       Impact factor: 9.236

3.  Acceptance testing for nuclear medicine instrumentation.

Authors:  Ellinor Busemann Sokole; Anna Płachcínska; Alan Britten
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-03       Impact factor: 9.236

4.  Routine quality control recommendations for nuclear medicine instrumentation.

Authors:  Ellinor Busemann Sokole; Anna Płachcínska; Alan Britten; Maria Lyra Georgosopoulou; Wendy Tindale; Rigobert Klett
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-03       Impact factor: 9.236

Review 5.  Standardization of Small Animal Imaging-Current Status and Future Prospects.

Authors:  Julia G Mannheim; Firat Kara; Janine Doorduin; Kerstin Fuchs; Gerald Reischl; Sayuan Liang; Marleen Verhoye; Felix Gremse; Laura Mezzanotte; Marc C Huisman
Journal:  Mol Imaging Biol       Date:  2018-10       Impact factor: 3.488

Review 6.  Attenuation Correction for Magnetic Resonance Coils in Combined PET/MR Imaging: A Review.

Authors:  Mootaz Eldib; Jason Bini; David D Faul; Niels Oesingmann; Charalampos Tsoumpas; Zahi A Fayad
Journal:  PET Clin       Date:  2015-11-27

7.  Monte Carlo simulation of digital photon counting PET.

Authors:  Julien Salvadori; Joey Labour; Freddy Odille; Pierre-Yves Marie; Jean-Noël Badel; Laëtitia Imbert; David Sarrut
Journal:  EJNMMI Phys       Date:  2020-04-25

Review 8.  Review of clinical practice utility of positron emission tomography with 18F-fluorodeoxyglucose in assessing tumour response to therapy.

Authors:  Andrea d'Amico
Journal:  Radiol Med       Date:  2014-08-26       Impact factor: 3.469

9.  The FLUKA Code: An Accurate Simulation Tool for Particle Therapy.

Authors:  Giuseppe Battistoni; Julia Bauer; Till T Boehlen; Francesco Cerutti; Mary P W Chin; Ricardo Dos Santos Augusto; Alfredo Ferrari; Pablo G Ortega; Wioletta Kozłowska; Giuseppe Magro; Andrea Mairani; Katia Parodi; Paola R Sala; Philippe Schoofs; Thomas Tessonnier; Vasilis Vlachoudis
Journal:  Front Oncol       Date:  2016-05-11       Impact factor: 6.244

10.  Background-based Delineation of Internal Tumor Volume in Static Positron Emission Tomography in a Phantom Study.

Authors:  Yangchun Chen; Xiangrong Chen; Ji-An Liu; Fanyong Li
Journal:  Asia Ocean J Nucl Med Biol       Date:  2016
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.