Literature DB >> 12025951

A novel realistic three-layer phantom for intravascular ultrasound imaging.

J Brunette1, R Mongrain, G Cloutier, M Bertrand, O F Bertrand, J C Tardif.   

Abstract

Intravascular ultrasound (IVUS) is an imaging modality that experienced a tremendous development over the last 20 years. Phantoms for IVUS are rare and poorly documented. The aim of this paper is to propose an original IVUS phantom that has geometries and specular textures closer to those of coronary arteries than conventional tube-like phantoms. The proposed phantom has a three-layer aspect, reproducing the intima, media and adventitia that compose the arterial wall. It is made of an agar-based compound, with water, glycerol and cellulose particles. Fourteen phantoms were quantified using IVUS. Six phantoms were evaluated by both photomacroscopy and IVUS. There was an excellent correlation between phantom dimensions evaluated by photomacroscopy and the nominal values (mold dimensions). The IVUS quantification of the phantom was closely correlated to the measurements obtained by photomacroscopy. These results demonstrate that a multilayer phantom, with known and reproducible dimensions and with realistic geometric and echographic properties has been developed.

Entities:  

Mesh:

Year:  2001        PMID: 12025951     DOI: 10.1023/a:1011996415966

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  27 in total

1.  Phantom for calibration of preoperative imaging modalities in endoluminal stent-graft repair of aortic aneurysms.

Authors:  S G Lalka; S M Stockberger; M S Johnson; D Hawes; A Aisen; S O Trerotola
Journal:  J Vasc Interv Radiol       Date:  1998 Sep-Oct       Impact factor: 3.464

2.  A wall-less vessel phantom for Doppler ultrasound studies.

Authors:  D W Rickey; P A Picot; D A Christopher; A Fenster
Journal:  Ultrasound Med Biol       Date:  1995       Impact factor: 2.998

3.  The effect of angulation on intravascular ultrasound imaging observed in vascular phantoms.

Authors:  J H Geselschap; M J Heilbron; F M Hussain; T M Daskalakis; E P Wilson; G E Kopchok; R A White
Journal:  J Endovasc Surg       Date:  1998-05

4.  Morphometric analysis in three-dimensional intracoronary ultrasound: an in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaque.

Authors:  C von Birgelen; C Di Mario; W Li; J C Schuurbiers; C J Slager; P J de Feyter; J R Roelandt; P W Serruys
Journal:  Am Heart J       Date:  1996-09       Impact factor: 4.749

5.  Colour velocity flow measurement: in vitro validation and application to human carotid arteries.

Authors:  C R Deane; H S Markus
Journal:  Ultrasound Med Biol       Date:  1997       Impact factor: 2.998

6.  Factors influencing the intravascular ultrasound dimensions and areas measured using mechanical transducers.

Authors:  V Bhargava; W F Penny; A Arbab-Zadeh
Journal:  Int J Card Imaging       Date:  1996-12

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  Limitations of angiography in the assessment of plaque distribution in coronary artery disease: a systematic study of target lesion eccentricity in 1446 lesions.

Authors:  G S Mintz; J J Popma; A D Pichard; K M Kent; L F Satler; Y C Chuang; R A DeFalco; M B Leon
Journal:  Circulation       Date:  1996-03-01       Impact factor: 29.690

9.  Arterial imaging with a new forward-viewing intravascular ultrasound catheter, I. Initial studies.

Authors:  J L Evans; K H Ng; M J Vonesh; B L Kramer; S N Meyers; T A Mills; B J Kane; W N Aldrich; Y T Jang; P G Yock
Journal:  Circulation       Date:  1994-02       Impact factor: 29.690

10.  Accurate three-dimensional reconstruction of intravascular ultrasound data. Spatially correct three-dimensional reconstructions.

Authors:  J L Evans; K H Ng; S G Wiet; M J Vonesh; W B Burns; M G Radvany; B J Kane; C J Davidson; S I Roth; B L Kramer; S N Meyers; D D McPherson
Journal:  Circulation       Date:  1996-02-01       Impact factor: 29.690

View more
  6 in total

1.  Advanced contour detection for three-dimensional intracoronary ultrasound: a validation--in vitro and in vivo.

Authors:  Gerhard Koning; Jouke Dijkstra; Clemens von Birgelen; Joan C Tuinenburg; Jean Brunette; Jean-Claude Tardif; Pranobe W Oemrawsingh; Christian Sieling; Sören Melsa; Johan H C Reiber
Journal:  Int J Cardiovasc Imaging       Date:  2002-08       Impact factor: 2.357

2.  The design and fabrication of two portal vein flow phantoms by different methods.

Authors:  Bryan E Yunker; Gerald D Dodd; S James Chen; Samuel Chang; Craig J Lanning; Ann L Scherzinger; Robin Shandas; Yusheng Feng; Kendall S Hunter
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

3.  Neutrophil adhesion on endothelial cells in a novel asymmetric stenosis model: effect of wall shear stress gradients.

Authors:  Leonie Rouleau; Ian B Copland; Jean-Claude Tardif; Rosaire Mongrain; Richard L Leask
Journal:  Ann Biomed Eng       Date:  2010-04-13       Impact factor: 3.934

4.  Ultrasound settings significantly alter arterial lumen and wall thickness measurements.

Authors:  Kathleen Potter; Christopher J Reed; Daniel J Green; Graeme J Hankey; Leonard F Arnolda
Journal:  Cardiovasc Ultrasound       Date:  2008-01-22       Impact factor: 2.062

5.  An investigation of industrial molding compounds for use in 3D ultrasound, MRI, and CT imaging phantoms.

Authors:  Bryan E Yunker; Dietmar Cordes; Ann L Scherzinger; Gerald D Dodd; Robin Shandas; Yusheng Feng; Kendall S Hunter
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

6.  A simple, realistic walled phantom for intravascular and intracardiac applications.

Authors:  Hareem Nisar; John Moore; Roberta Piazza; Efthymios Maneas; Elvis C S Chen; Terry M Peters
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-06-10       Impact factor: 2.924

  6 in total