Literature DB >> 12017171

The effects of sodium hypochlorite concentrations on the accuracy of an apex locating device.

A Cemal Tinaz1, L Sibel Sevimli, Güliz Görgül, Emin G Türköz.   

Abstract

This study aimed to evaluate Root ZX accuracy with different NaOCl concentrations and to observe effects of the alginate model when NaOCl was used in the canal during electronic measurements. Fifty extracted single-rooted, single-canal human teeth were used in five experimental groups. NaOCl concentrations of 5.25%, 2.65%, 1.00%, and 0.50%, respectively, were injected into the root canals of teeth in four groups and distilled water in control group 5. After measuring root lengths with Root ZX, the files were locked in place. There were no statistically significant differences among all the groups (p > 0.95) when evaluating the distance of the file tips and apical constriction or for the distance from file tip to apical foramen. Root ZX could be used in root canal length measurements with various NaOCl concentrations. Designation of apical constriction needs more care. The alginate model could be used for in vitro electronic measurements with various NaOCl concentrations.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12017171     DOI: 10.1097/00004770-200203000-00004

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  9 in total

1.  Effect of Sodium Hypochlorite Concentration on Electronic Apex Locator Reliability.

Authors:  Franck Diemer; Emma Plews; Marie Georgelin-Gurgel; Lora Mishra; Hyeon-Cheol Kim
Journal:  Materials (Basel)       Date:  2022-01-23       Impact factor: 3.623

2.  Comparison of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study.

Authors:  J Paras Mull; Vinutha Manjunath; Mk Manjunath
Journal:  J Conserv Dent       Date:  2012-04

3.  In vitro evaluation of Root ZX and Raypex 6 in teeth with different apical diameters.

Authors:  Ugur Aydin; Emrah Karataslioglu; Fatih Aksoy; Cihan Yildirim
Journal:  J Conserv Dent       Date:  2015 Jan-Feb

4.  In vitro comparison of working length determination using three different electronic apex locators.

Authors:  Alper Kuştarci; Dilara Arslan; Demet Altunbaş
Journal:  Dent Res J (Isfahan)       Date:  2014-09

5.  The Effect of File Size and Type and Irrigation Solutions on the Accuracy of Electronic Apex Locators: An In Vitro Study on Canine Teeth.

Authors:  Maciej Janeczek; Piotr Kosior; Dagmara Piesiak-Pańczyszyn; Krzysztof Dudek; Aleksander Chrószcz; Agnieszka Czajczyńska-Waszkiewicz; Małgorzata Kowalczyk-Zając; Aleksandra Gabren-Syller; Karol Kirstein; Aleksandra Skalec; Ewelina Bryła; Maciej Dobrzyński
Journal:  Biomed Res Int       Date:  2016-09-26       Impact factor: 3.411

6.  An Invitro Evaluation of the Accuracy of Two Electronic Apex Locators to Determine Working Length in the Presence of Various Irrigants.

Authors:  Ashwini B Prasad; Srivastava Harshit; Srivastava Arora Aastha; Raisingani Deepak
Journal:  Ethiop J Health Sci       Date:  2016-09

7.  Ex Vivo Evaluation of the Accuracy of 3 Electronic Apex Locators in Different Environments: A Micro-Computed Tomography Study.

Authors:  Firdevs Çınar; Yakup Üstün
Journal:  Eur Endod J       Date:  2020-12

8.  In vitro detection of simulated apical root perforation with two electronic apex locators.

Authors:  Kiumars Nazari Moghaddam; Shahrzad Nazari; Leila Shakeri; Kiamars Honardar; Farshid Mirmotalebi
Journal:  Iran Endod J       Date:  2010-02-20

9.  The influence of two forms of chlorhexidine on the accuracy of contemporary electronic apex locators.

Authors:  Ewa Marek; Ryta Łagocka; Katarzyna Kot; Krzysztof Woźniak; Mariusz Lipski
Journal:  BMC Oral Health       Date:  2019-12-31       Impact factor: 2.757

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.