Literature DB >> 12005147

Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach.

Haw-Ming Huang1, Sheng-Yang Lee, Ching-Ying Yeh, Che-Tong Lin.   

Abstract

Resonance frequency analysis (RFA) has been used by several investigators to assess the boundary conditions of dental implants. The goal of the current study was to determine the vibrating behavior of a dental implant under various surrounding bone conditions. A 3D finite element (FE) model of a cylinder-type titanium implant was developed. In this model, the implant was embedded into a cubic section of bone. The model was first validated using a series of modal testing experiments. The effects of bony conditions on the resonance frequencies of the implant were computed with different bone types and bone densities. Our results show that the resonance frequency of the implant with type III surrounding bone decreased linearly (r = -0.996, P < 0.01) from 17.9 kHz (without loss in bone density) to 0.6 kHz (90% loss in bone density) when the bone densities were decreased. On the other hand, without bone loss, the highest resonance frequency value (36.1 kHz) was found when the implant was placed into type I surrounding bone. In contrast, the resonance frequency of the implant with type IV bone quality was found to be 9.9 kHz, which is almost four-fold less than that found in the type I model. These results suggest that RFA could serve as a non-invasive diagnostic tool for detecting the stability of dental implants during the healing stages and in subsequent routine follow-up care after treatment.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12005147     DOI: 10.1034/j.1600-0501.2002.130108.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  16 in total

1.  Natural frequency assessment of stability of root keeper magnetic devices.

Authors:  H M Huang; D Z Liu; Y Y Shiau; C Y Yeh; C T Lin; S Y Lee
Journal:  Med Biol Eng Comput       Date:  2004-05       Impact factor: 2.602

2.  Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

Authors:  Annette Rabel; Steffen Gerhard Köhler; Andrea Maria Schmidt-Westhausen
Journal:  Clin Oral Investig       Date:  2007-03-31       Impact factor: 3.573

3.  Effects on the torsional vibration behavior in the investigation of dental implant osseointegration using resonance frequency analysis: a numerical approach.

Authors:  Min Zhai; Bing Li; Dehua Li
Journal:  Med Biol Eng Comput       Date:  2017-02-07       Impact factor: 2.602

Review 4.  Osseointegration: an update.

Authors:  S Parithimarkalaignan; T V Padmanabhan
Journal:  J Indian Prosthodont Soc       Date:  2013-01-11

5.  Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test.

Authors:  Dorjpalam Bayarchimeg; Hee Namgoong; Byung Kook Kim; Myung Duk Kim; Sungtae Kim; Tae-Il Kim; Yang Jo Seol; Yong Moo Lee; Young Ku; In-Chul Rhyu; Eun Hee Lee; Ki-Tae Koo
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614

6.  Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value.

Authors:  Hong-Gi Yoon; Seong-Joo Heo; Jai-Young Koak; Seong-Kyun Kim; Su-Young Lee
Journal:  J Adv Prosthodont       Date:  2011-03-31       Impact factor: 1.904

7.  Association between implant apex and sinus floor in posterior maxilla dental implantation: A three-dimensional finite element analysis.

Authors:  Xu Yan; Xinwen Zhang; Weichao Chi; Hongjun Ai; Lin Wu
Journal:  Exp Ther Med       Date:  2015-01-22       Impact factor: 2.447

8.  The Effect of Flapless and Full-thickness Flap Techniques on Implant Stability During the Healing Period.

Authors:  Mohammed Jasim Al-Juboori; Shafluzan Bin AbdulRahaman
Journal:  Open Dent J       Date:  2015-07-31

9.  Measurement of primary and secondary stability of dental implants by resonance frequency analysis method in mandible.

Authors:  Mehran Shokri; Arash Daraeighadikolaei
Journal:  Int J Dent       Date:  2013-05-13

10.  Comparison of implant primary stability between maxillary edentulous ridges receiving intramembranous origin block grafts.

Authors:  Alberto Monje; Florencio Monje; Fernando Suarez; Raúl González-García; Laura Villanueva-Alcojol; Agustín Garcia-Nogales; Pablo Galindo-Moreno; Hom-Lay Wang
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-05-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.