Literature DB >> 12002705

A femoral arteriovenous shunt facilitates arterial whole blood sampling in animals.

Bruno Weber1, Cyrill Burger, Peter Biro, Alfred Buck.   

Abstract

In this study we evaluated on-line continuous blood sampling in a femoral arteriovenous (a-v) shunt for use in quantitative tracer studies using gamma-emitting radionuclides in animals. The shunt consisted of 40 cm polyethylene tubing (PE-50) guided through a coincidence probe. Two three-way valves allowed blood pressure measurements and tracer injection. Blood flow in the shunt and the impulse response function (IRF) were assessed using heparinized human blood mixed with fluorine-18 fluorodeoxyglucose (FDG). In vivo experiments were performed in eight male rats (300-350 g) anaesthetized with halothane. In three rats, manual blood sampling was performed in parallel with on-line sampling. In another five animals, the arterial whole blood activity was recorded on-line for 40 min. For the experiments 150-180 MBq FDG was injected over 35 s. Blood flow in the shunt was 23.6, 29.2 and 42.8 ml/h at 100, 120 and 160 mmHg, respectively. The IRF was characterized by minimal dispersion (1-2 s FWHM). Deconvolution of the measured arterial input curves with the IRF changed the measured curve only minimally. Whole blood radioactivity concentration derived from manual and on-line sampling were in excellent agreement. The curves derived from on-line sampling were of high statistical quality. In conclusion, a femoral a-v shunt allows multiple manipulations such as measurement of the arterial whole blood activity, continuous blood pressure monitoring, injection of the tracer and collection of blood samples if necessary. It is not associated with blood loss if the collection of blood samples is not required. It is more convenient to use than manual sampling, the peak of the input curve is never missed and the input curves are of high statistical quality.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12002705     DOI: 10.1007/s00259-001-0712-2

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  15 in total

1.  Response-Derived Input Function Estimation for Dynamic Contrast-Enhanced MRI Demonstrated by Anti-DLL4 Treatment in a Murine U87 Xenograft Model.

Authors:  Matthew D Silva; Brittany Yerby; Jodi Moriguchi; Albert Gomez; H Toni Jun; Angela Coxon; Sharon E Ungersma
Journal:  Mol Imaging Biol       Date:  2017-10       Impact factor: 3.488

2.  Cross-validation of input functions obtained by H₂ 15O PET imaging of rat heart and a blood flow-through detector.

Authors:  Nobuyuki Kudomi; Hannu Sipilä; Anu Autio; Vesa Oikonen; Heidi Liljenbäck; Miikka Tarkia; Jarno Laivola; Jarkko Johansson; Mika Teräs; Anne Roivainen
Journal:  Mol Imaging Biol       Date:  2012-08       Impact factor: 3.488

3.  Metabotropic glutamate receptor mGluR5 is not involved in the early hemodynamic response.

Authors:  Novella Calcinaghi; Renaud Jolivet; Matthias T Wyss; Simon M Ametamey; Fabrizio Gasparini; Alfred Buck; Bruno Weber
Journal:  J Cereb Blood Flow Metab       Date:  2011-07-06       Impact factor: 6.200

Review 4.  Quantitative Rodent Brain Receptor Imaging.

Authors:  Kristina Herfert; Julia G Mannheim; Laura Kuebler; Sabina Marciano; Mario Amend; Christoph Parl; Hanna Napieczynska; Florian M Maier; Salvador Castaneda Vega; Bernd J Pichler
Journal:  Mol Imaging Biol       Date:  2020-04       Impact factor: 3.488

5.  A probable dual mode of action for both L- and D-lactate neuroprotection in cerebral ischemia.

Authors:  Ximena Castillo; Katia Rosafio; Matthias T Wyss; Konstantin Drandarov; Alfred Buck; Luc Pellerin; Bruno Weber; Lorenz Hirt
Journal:  J Cereb Blood Flow Metab       Date:  2015-06-03       Impact factor: 6.200

6.  Simplified quantification of small animal [18F]FDG PET studies using a standard arterial input function.

Authors:  Philipp T Meyer; Valentina Circiumaru; Christopher A Cardi; Daniel H Thomas; Harshali Bal; Paul D Acton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-05-13       Impact factor: 9.236

7.  Improved derivation of input function in dynamic mouse [18F]FDG PET using bladder radioactivity kinetics.

Authors:  Koon-Pong Wong; Xiaoli Zhang; Sung-Cheng Huang
Journal:  Mol Imaging Biol       Date:  2013-08       Impact factor: 3.488

8.  Use of a beta microprobe system to measure arterial input function in PET via an arteriovenous shunt in rats.

Authors:  Geoff Warnock; Mohamed-Ali Bahri; David Goblet; Fabrice Giacomelli; Christian Lemaire; Joel Aerts; Alain Seret; Xavier Langlois; Andre Luxen; Alain Plenevaux
Journal:  EJNMMI Res       Date:  2011-08-10       Impact factor: 3.138

9.  FDG kinetic modeling in small rodent brain PET: optimization of data acquisition and analysis.

Authors:  Malte F Alf; Marianne I Martić-Kehl; Roger Schibli; Stefanie D Krämer
Journal:  EJNMMI Res       Date:  2013-08-06       Impact factor: 3.138

10.  Development and performance test of an online blood sampling system for determination of the arterial input function in rats.

Authors:  Friedrich Roehrbacher; Jens P Bankstahl; Marion Bankstahl; Thomas Wanek; Johann Stanek; Michael Sauberer; Julia Muellauer; Thales Schroettner; Oliver Langer; Claudia Kuntner
Journal:  EJNMMI Phys       Date:  2015-01-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.