Temperature dependence of commercially available diode detectors.

Amarjit S Saini1, Timothy C Zhu.   

Abstract

Temperature dependence of commercially available n- and p-type diodes were studied experimentally under both high instantaneous dose rate (pulsed) and low dose rate (continuous) radiation. The sensitivity versus temperature was measured at SSD = 80 or 100 cm, 10 x 10 cm2, and 5 cm depth in a 30 x 30 x 30 cm3 water phantom between 10 degrees C and 35 degrees C. The response was linear for all the diode detectors. The temperature coefficient (or sensitivity variation with temperature, svwt) was dose rate independent for preirradiated diodes. They were (0.30 +/- 0.01)%/degrees C, (0.36 +/- 0.03)%/degrees C, and (0.29 +/- 0.08)%/degrees C for QED p-type, EDP p-type, and Isorad n-type diodes, respectively. The temperature coefficient for unirradiated n-type diodes was different under low dose rate [(0.16 to 0.45)%/degrees C, continuous, cobalt] and high instantaneous dose rate [(0.07 +/- 0.02)%/degrees C, pulsed radiation]. Moreover, the temperature coefficient varies among individual diodes. Similarly, the temperature coefficient for a special unirradiated QED p-type diode was different under low dose rate (0.34%/degrees C, cobalt) and high instantaneous dose rate [(0.26 +/- 0.01)%/degrees C, pulsed radiation]. Sufficient preirradiation can eliminate dose rate dependence of the temperature coefficient. On the contrary, preirradiation cannot eliminate dose rate dependence of the diode sensitivity itself.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11991134     DOI: 10.1118/1.1461842

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

2.  Radioluminescence characterization of in situ x-ray nanodosimeters: Potential real-time monitors and modulators of external beam radiation therapy.

Authors:  Jeffrey S Souris; Shih-Hsun Cheng; Charles Pelizzari; Nai-Tzu Chen; Patrick La Riviere; Chin-Tu Chen; Leu-Wei Lo
Journal:  Appl Phys Lett       Date:  2014-11-20       Impact factor: 3.791

3.  Monte Carlo-based energy response studies of diode dosimeters in radiotherapy photon beams.

Authors:  C Arun; T Palani Selvam; Verma Dinkar; Prabhat Munshi; Manjit Singh Kalra
Journal:  Radiol Phys Technol       Date:  2012-11-20

4.  Silicon diodes as an alternative to diamond detectors for depth dose curves and profile measurements of photon and electron radiation.

Authors:  Christian Scherf; Christiane Peter; Jussi Moog; Jörg Licher; Eugen Kara; Klemens Zink; Claus Rödel; Ulla Ramm
Journal:  Strahlenther Onkol       Date:  2009-08-04       Impact factor: 3.621

5.  A method to correct for temperature dependence and measure simultaneously dose and temperature using a plastic scintillation detector.

Authors:  Francois Therriault-Proulx; Landon Wootton; Sam Beddar
Journal:  Phys Med Biol       Date:  2015-09-25       Impact factor: 3.609

6.  Characterization of a microSilicon diode detector for small-field photon beam dosimetry.

Authors:  Yuichi Akino; Masateru Fujiwara; Keita Okamura; Hiroya Shiomi; Hirokazu Mizuno; Fumiaki Isohashi; Osamu Suzuki; Yuji Seo; Keisuke Tamari; Kazuhiko Ogawa
Journal:  J Radiat Res       Date:  2020-05-22       Impact factor: 2.724

7.  A Monte Carlo and experimental investigation of the dosimetric behavior of low- and medium-perturbation diodes used for entrance in vivo dosimetry in megavoltage photon beams.

Authors:  Mohammad Amin Mosleh-Shirazi; Sareh Karbasi; Daryoush Shahbazi-Gahrouei; Shahram Monadi
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

8.  Percent depth-dose distribution discrepancies from very small volume ion chambers.

Authors:  Vikren Sarkar; Brian Wang; Hui Zhao; Bart Lynch; Joshua A James; Kiernan T McCullough; Bill J Salter
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

Review 9.  From cultured to uncultured genome sequences: metagenomics and modeling microbial ecosystems.

Authors:  Daniel R Garza; Bas E Dutilh
Journal:  Cell Mol Life Sci       Date:  2015-08-09       Impact factor: 9.261

10.  Evaluation of a biplanar diode array dosimeter for quality assurance of step-and-shoot IMRT.

Authors:  Vladimir Feygelman; Kenneth Forster; Daniel Opp; Görgen Nilsson
Journal:  J Appl Clin Med Phys       Date:  2009-09-30       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.