X-ray dose and associated risks from radiofrequency catheter ablation procedures.

S L McFadden1, R B Mooney, P H Shepherd.   

Abstract

The objectives of this study were to quantify the ionizing radiation exposure to patient and operator during radiofrequency (RF) catheter ablation and to estimate the risks associated with this exposure. The study consisted of 50 RF ablation procedures, all performed in the same electrophysiology laboratory. Occupational dose to two cardiologists who performed the procedures was measured using film badges and extremity thermoluminescent dosemeters (TLDs). Absorbed dose to the patients' skin was measured using TLDs. Dose-area product (DAP) was also measured. The effective dose to the cardiologists was less than 0.15 mSv per month. The mean equivalent dose to the cardiologists' left hand and forehead was 0.24 mSv and 0.05 mSv, respectively, per RF ablation procedure, which was more than twice the mean dose for the other cardiology procedures carried out in the centre. Yearly occupational dose to the cardiologists was much lower than the relevant statutory dose limits. The mean skin dose, fluoroscopy time and DAP to patients were 0.81 Gy, 67 min and 123 Gycm(2), respectively, with a maximum of 3.2 Gy, 164 minutes and 430 Gycm(2), respectively. Mean effective dose to patients was 17 mSv, from which the excess risk of developing fatal cancer is 0.1%. Six of the patients (12%) received a skin dose above the threshold dose for radiation skin injury (2 Gy), but no skin injuries were reported. Patient skin dose and DAP were closely correlated and this allows DAP to be used to monitor patient skin dose in real-time. DAP levels were locally adopted as diagnostic reference levels (DRLs) that provide an indication during a procedure that a patient is at risk of suffering deterministic skin injury.

Entities:  

Mesh:

Year:  2002        PMID: 11932220     DOI: 10.1259/bjr.75.891.750253

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  17 in total

1.  How to set up and apply reference levels in fluoroscopy at a national level.

Authors:  A Aroua; H Rickli; J-C Stauffer; P Schnyder; P R Trueb; J-F Valley; P Vock; F R Verdun
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

2.  Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner.

Authors:  Bradley P McCabe; Michael A Speidel; Tina L Pike; Michael S Van Lysel
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

3.  Reference levels and patient doses in interventional cardiology procedures in Greece.

Authors:  George Simantirakis; Christina Koukorava; Maria Kalathaki; Christos Pafilis; Ioannis Kaisas; Sotirios Economides; Costas J Hourdakis; Vassiliki Kamenopoulou; Evaggelos Georgiou
Journal:  Eur Radiol       Date:  2013-04-06       Impact factor: 5.315

4.  Impact of respiration gating on image integration guided atrial fibrillation ablation.

Authors:  Emin Evren Özcan; Gabor Szeplaki; Tamas Tahin; Istvan Osztheimer; Szabolcs Szilagyi; Astrid Apor; Pal Maurovich Horvath; Hajnalka Vago; Béla Merkely; Laszlo Geller
Journal:  Clin Res Cardiol       Date:  2014-05-07       Impact factor: 5.460

5.  Advanced electrophysiologic mapping systems: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2006-03-01

6.  Evaluation of exposure dose to patients undergoing catheter ablation procedures--a phantom study.

Authors:  S Seguchi; T Aoyama; S Koyama; C Kawaura; K Fujii
Journal:  Eur Radiol       Date:  2008-05-20       Impact factor: 5.315

7.  Impact of a computer assisted navigation system on radiation exposure during pediatric ablation procedures.

Authors:  Andrew L Papez; Mohamad Al-Ahdab; Macdonald Dick; Peter S Fischbach
Journal:  J Interv Card Electrophysiol       Date:  2007-08-01       Impact factor: 1.900

Review 8.  The Growing Culture Of A Minimally Fluoroscopic Approach In Electrophysiology Lab.

Authors:  Michela Casella; Eleonora Russo; Francesca Pizzamiglio; Sergio Conti; Ghaliah Al-Mohani; Daniele Colombo; Victor Casula; Yuri D Alessandra; Viviana Biagioli; Corrado Carbucicchio; Stefania Riva; Gaetano Fassini; Massimo Moltrasio; Fabrizio Tundo; Martina Zucchetti; Benedetta Majocchi; Vittoria Marino; Giovanni Forleo; Pasquale Santangeli; Luigi Di Biase; Antonio Dello Russo; Andrea Natale; Claudio Tondo
Journal:  J Atr Fibrillation       Date:  2014-08-31

9.  Pulmonary venous anatomy imaging with low-dose, prospectively ECG-triggered, high-pitch 128-slice dual-source computed tomography.

Authors:  Wai-ee Thai; Bryan Wai; Kaity Lin; Teresa Cheng; E Kevin Heist; Udo Hoffmann; Jagmeet P Singh; Quynh A Truong
Journal:  Circ Arrhythm Electrophysiol       Date:  2012-05-14

10.  Patient radiation doses in interventional cardiology procedures.

Authors:  Ioannis Pantos; Georgios Patatoukas; Demosthenes G Katritsis; Efstathios Efstathopoulos
Journal:  Curr Cardiol Rev       Date:  2009-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.