Literature DB >> 11927480

Utility of esophageal Doppler as a minimally invasive hemodynamic monitor: a review.

Kevin B Laupland1, Colin J Bands.   

Abstract

PURPOSE: The current bedside "gold standard" for cardiac output (CO) monitoring is thermodilution using a pulmonary artery catheter (PAC) but there is a number of risks associated with its use. The primary objective of this review was to evaluate the utility of esophageal Doppler (ED) as a minimally invasive monitor of CO. SOURCE: Medline literature search from 1966 to 2001 with citation review for studies comparing ED to PAC thermodilution for CO in perioperative and critically ill patients. PRINCIPAL
FINDINGS: Twenty-five publications were identified comparing ED and PAC measurement of CO in a broad range of patients. There was a good overall correlation between CO determined by ED and thermodilution (n = 18 studies, median R = 0.89, range 0.52 to 0.98) and minimal bias (n = 13, median -0.01, range 1.38 to 2 L x min(-1)). The precision of ED was only fair overall as assessed by limits of agreement. The ED technique was found to be responsive in detecting changes in thermodilution CO and was reliable demonstrating both low intra- and inter-observer variation. ED was reportedly easy to insert after minimal training and was safe, with no significant complications identified.
CONCLUSION: ED is a practical, reliable, and valid device for measuring CO in perioperative and critically ill patients. Further studies with larger numbers of patients are needed to determine if the limited precision observed is inherent to the technique, the diagnoses of patients studied, or the small sample sizes.

Entities:  

Mesh:

Year:  2002        PMID: 11927480     DOI: 10.1007/BF03017329

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  19 in total

1.  Unexpected left main stem bronchus cardiac output measurement.

Authors:  Muriel M Hilkens; Frank H F van Haren; Johannes G van der Hoeven
Journal:  Intensive Care Med       Date:  2003-06-12       Impact factor: 17.440

2.  Health technology assessment in critical care.

Authors:  Damon C Scales; Andreas Laupacis
Journal:  Intensive Care Med       Date:  2007-10-20       Impact factor: 17.440

Review 3.  [Hemodynamic monitoring in one-lung ventilation].

Authors:  S Haas; R Kiefmann; V Eichhorn; A E Goetz; D A Reuter
Journal:  Anaesthesist       Date:  2009-11       Impact factor: 1.041

Review 4.  Transesophageal Doppler devices: A technical review.

Authors:  Patrick Schober; Stephan A Loer; Lothar A Schwarte
Journal:  J Clin Monit Comput       Date:  2009-10-20       Impact factor: 2.502

Review 5.  Clinician-performed ultrasound in hemodynamic and cardiac assessment: a synopsis of current indications and limitations.

Authors:  N Kelly; R Esteve; T J Papadimos; R P Sharpe; S A Keeney; R DeQuevedo; M Portner; D P Bahner; S P Stawicki
Journal:  Eur J Trauma Emerg Surg       Date:  2015-01-08       Impact factor: 3.693

Review 6.  Newer methods of cardiac output monitoring.

Authors:  Yatin Mehta; Dheeraj Arora
Journal:  World J Cardiol       Date:  2014-09-26

7.  Continuous, non-invasive techniques to determine cardiac output in children after cardiac surgery: evaluation of transesophageal Doppler and electric velocimetry.

Authors:  Stephan Schubert; Thomas Schmitz; Markus Weiss; Nicole Nagdyman; Michael Huebler; Vladimir Alexi-Meskishvili; Felix Berger; Brigitte Stiller
Journal:  J Clin Monit Comput       Date:  2008-07-30       Impact factor: 2.502

8.  Effect of intraoperative transesophageal Doppler-guided fluid therapy versus central venous pressure-guided fluid therapy on renal allograft outcome in patients undergoing living donor renal transplant surgery: a comparative study.

Authors:  Divya Srivastava; Sandeep Sahu; Abhilash Chandra; Tanmay Tiwari; Sanjay Kumar; P K Singh
Journal:  J Anesth       Date:  2015-07-28       Impact factor: 2.078

9.  Optimization of cardiac preload during laparoscopic donor nephrectomy: a preliminary study of central venous pressure versus esophageal Doppler monitoring.

Authors:  L S Feldman; M Anidjar; P Metrakos; D Stanbridge; G M Fried; F Carli
Journal:  Surg Endosc       Date:  2004-01-14       Impact factor: 4.584

10.  Exploring measurement biases associated with esophageal Doppler monitoring in critically ill patients in intensive care unit.

Authors:  Peter S Stawicki; Benjamin Braslow; Vicente H Gracias
Journal:  Ann Thorac Med       Date:  2007-10       Impact factor: 2.219

View more