Electrical current distribution under transthoracic defibrillation and pacing electrodes.

S Papazov1, Z Kostov, I Daskalov.   

Abstract

The known effect of high current density under the perimeter of defibrillation electrodes, leading to skin damage and even severe burns in some cases, has been considered by many investigators. Two main approaches for improvement were proposed: (i) interfacing with layers of varying and high resistivity and (ii) lengthening and shaping the perimeter line. Using finite element and physical modelling, it is shown that the second approach does not yield significant improvement in the distribution uniformity. Moreover, the application of high resistivity layers is unacceptable in dibrillation. The use of a low resistance layer with a diameter covering and extending over the metal plate by at least 2.5 mm results in better uniformity. A similar effect can be obtained by recessing the metal plate in an isolating support--an approach adopted from implantable neurostimulation electrodes. These two versions can be applied in combination.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11924843     DOI: 10.1080/03091900110102454

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  6 in total

1.  Finite difference and lead field methods in designing implantable ECG monitor.

Authors:  Juho Väisänen; Jari Hyttinen; Jaakko Malmivuo
Journal:  Med Biol Eng Comput       Date:  2006-08-11       Impact factor: 2.602

2.  Design of electrodes and current limits for low frequency electrical impedance tomography of the brain.

Authors:  O Gilad; L Horesh; D S Holder
Journal:  Med Biol Eng Comput       Date:  2007-06-28       Impact factor: 2.602

3.  Impedance-gradient electrode reduces skin irritation induced by transthoracic defibrillation.

Authors:  P F Meyer; P D Gadsby; D Van Sickle; W E Schoenlein; K S Foster; G P Graber
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

4.  The effects of concentric ring electrode electrical stimulation on rat skin.

Authors:  W Besio; V Sharma; J Spaulding
Journal:  Ann Biomed Eng       Date:  2010-01-20       Impact factor: 3.934

5.  Reduction of edge effect on disk electrodes by optimized current waveform.

Authors:  Boshuo Wang; Artin Petrossians; James D Weiland
Journal:  IEEE Trans Biomed Eng       Date:  2014-08       Impact factor: 4.538

6.  Estimation of current density distribution under electrodes for external defibrillation.

Authors:  Vessela Tz Krasteva; Sava P Papazov
Journal:  Biomed Eng Online       Date:  2002-12-16       Impact factor: 2.819

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.