Finite difference and lead field methods in designing implantable ECG monitor.

Juho Väisänen1, Jari Hyttinen, Jaakko Malmivuo.   

Abstract

To minimize time-consuming and expensive in vitro and in vivo testing, information regarding the effects of implantation and the implants on measurements should be available during the designing of active implantable devices measuring bioelectric signals such as electrocardiograms (ECG). Modeling offers a fairly inexpensive and effective means of studying and demonstrating the effects of implantation on ECG measurements prior to any in vivo tests, and can thus provide the designer with valuable information. Finite difference model (FDM) and lead field approaches offer straightforward and effective modeling methods supporting the designing of active implantable ECG devices. The present study demonstrates such methods in developing and studying ECG implants. They were applied in demonstrating the effects of implant dimensions and of electrode implantation on the measurement sensitivity of the ECG device. The results of the simulations indicated that the interelectrode distance is the factor of the implant design determining the lead sensitivity. Other parameters related implant dimensions and shape have minor effect on the morphology of the ECG or on the average sensitivity of the measurement. This is shown for example when the interelectrode distance was reduced to 1/3 of original the average lead sensitivity decreased by 69.1% while larger relative changes in other dimensions produced clearly smaller changes. It was also observed here that implanting the electrodes deeper under the skin has major effects on the local sensitivities in heart muscle and thus affect to the morphology of the ECG. The study indicated also that non-conducting medium (i.e. implant insulated body) between the electrodes increases the sensitivity on heart muscle compared to cases where only electrodes are implanted.

Mesh:

Year:  2006        PMID: 17031715     DOI: 10.1007/s11517-006-0092-7

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  20 in total

1.  Accuracy of two dipolar inverse algorithms applying reciprocity for forward calculation.

Authors:  P Laarne; J Hyttinen; S Dodel; J Malmivuo; H Eskola
Journal:  Comput Biomed Res       Date:  2000-06

2.  The feasibility of ST-segment monitoring with a subcutaneous device.

Authors:  Zhendong Song; Janice Jenkins; Martin Burke; Robert Arzbaecher
Journal:  J Electrocardiol       Date:  2004       Impact factor: 1.438

3.  The Visible Human Project.

Authors:  M J Ackerman
Journal:  J Biocommun       Date:  1991

4.  Potential and current density distributions of cranial electrotherapy stimulation (CES) in a four-concentric-spheres model.

Authors:  M Ferdjallah; F X Bostick; R E Barr
Journal:  IEEE Trans Biomed Eng       Date:  1996-09       Impact factor: 4.538

Review 5.  Computational and numerical methods for bioelectric field problems.

Authors:  C R Johnson
Journal:  Crit Rev Biomed Eng       Date:  1997

6.  A software implementation for detailed volume conductor modelling in electrophysiology using finite difference method.

Authors:  P Kauppinen; J Hyttinen; P Laarne; J Malmivuo
Journal:  Comput Methods Programs Biomed       Date:  1999-02       Impact factor: 5.428

7.  Validation of a detailed computer model for the electric fields in the brain.

Authors:  P Laarne; H Eskola; J Hyttinen; V Suihko; J Malmivuo
Journal:  J Med Eng Technol       Date:  1995 Mar-Jun

8.  Use of implantable loop recorders in the diagnosis and management of syncope.

Authors:  D J Farwell; N Freemantle; A N Sulke
Journal:  Eur Heart J       Date:  2004-07       Impact factor: 29.983

9.  Computational studies of transthoracic and transvenous defibrillation in a detailed 3-D human thorax model.

Authors:  D B Jorgenson; D R Haynor; G H Bardy; Y Kim
Journal:  IEEE Trans Biomed Eng       Date:  1995-02       Impact factor: 4.538

10.  Estimation of current density distribution under electrodes for external defibrillation.

Authors:  Vessela Tz Krasteva; Sava P Papazov
Journal:  Biomed Eng Online       Date:  2002-12-16       Impact factor: 2.819

View more
  3 in total

1.  New method for analysing sensitivity distributions of electroencephalography measurements.

Authors:  Juho Väisänen; Outi Väisänen; Jaakko Malmivuo; Jari Hyttinen
Journal:  Med Biol Eng Comput       Date:  2008-01-10       Impact factor: 2.602

Review 2.  Wireless and inductively powered implant for measuring electrocardiogram.

Authors:  Jarno Riistama; Juho Väisänen; Sami Heinisuo; Hanna Harjunpää; Satu Arra; Kati Kokko; Maunu Mäntylä; Jutta Kaihilahti; Pekka Heino; Minna Kellomäki; Outi Vainio; Jukka Vanhala; Jukka Lekkala; Jari Hyttinen
Journal:  Med Biol Eng Comput       Date:  2007-10-11       Impact factor: 2.602

3.  Lead field theory provides a powerful tool for designing microelectrode array impedance measurements for biological cell detection and observation.

Authors:  Marcel Böttrich; Jarno M A Tanskanen; Jari A K Hyttinen
Journal:  Biomed Eng Online       Date:  2017-06-26       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.