Changes in prosthetic screw stability because of misfit of implant-supported prostheses.

Lulwa Ebrahim E al-Turki, John Chai, Eugene P Lautenschlager, Mark C Hutten.   

Abstract

PURPOSE: The effect of two levels of prosthesis misfit on prosthetic screw stability was evaluated.
MATERIALS AND METHODS: Two levels of vertical discrepancies--100 and 175 microns--were introduced between an implant-supported complete denture and the terminal abutment. An implant-supported complete denture without vertical discrepancy served as a control. Cyclic load was delivered vertically on the cantilever portion of the prosthesis next to the terminal abutment for 48 hours for each trial. A total of seven sets of new screws were tested for each level of fit.
RESULTS: The results revealed significant prosthetic screw instability at both the 100- and 175-micron levels of discrepancy.
CONCLUSION: Vertical discrepancies of 100 and 175 microns introduced between an implant-supported fixed complete denture and the terminal abutment resulted in significant prosthetic screw instability.

Mesh:

Year:  2002        PMID: 11887597

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  16 in total

1.  Teeth movement in denture and implant-supported prosthesis influenced by microwave flask systems.

Authors:  Rafael L X Consani; Leonardo G Sonehara; Marcelo F Mesquita; Valentim A R Barão; Conrado R Caetano
Journal:  J Oral Biol Craniofac Res       Date:  2015-07-15

2.  Effect of vertical misfit and clip material on stress distribution of overdentures under masticatory loading.

Authors:  Mateus Bertolini Fernandes Dos Santos; Bruno Massucato Zen; Atais Bacchi
Journal:  Med Biol Eng Comput       Date:  2015-12-11       Impact factor: 2.602

3.  In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants.

Authors:  Leonardo Ciocca; Roberto Meneghello; Carlo Monaco; Gianpaolo Savio; Lorenzo Scheda; Maria Rosaria Gatto; Paolo Baldissara
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-02       Impact factor: 2.924

4.  Influence of prosthetic screw material on joint stability in passive and non-passive implant-supported dentures.

Authors:  Aloísio Oro Spazzin; Guilherme Elias Pessanha Henriques; Mauro Antônio de Arruda Nóbilo; Rafael Leonardo Xediek Consani; Lourenço Correr-Sobrinho; Marcelo Ferraz Mesquita
Journal:  Open Dent J       Date:  2009-12-30

5.  Correlation between microleakage and screw loosening at implant-abutment connection.

Authors:  Cem Sahin; Simel Ayyildiz
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

6.  Leakage evaluation of original and compatible implant-abutment connections: In vitro study using Rhodamine B.

Authors:  Antoine Berberi; George Tehini; Khaldoun Rifai; Farah Bou Nasser Eddine; Bassam Badran; Haidar Akl
Journal:  J Dent Biomech       Date:  2014-08-11

7.  Resistance of three implant-abutment interfaces to fatigue testing.

Authors:  Cleide Gisele Ribeiro; Maria Luiza Cabral Maia; Susanne S Scherrer; Antonio Carlos Cardoso; H W Anselm Wiskott
Journal:  J Appl Oral Sci       Date:  2011-07-01       Impact factor: 2.698

8.  Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment.

Authors:  Rudys Rodolfo de Jesus Tavarez; Wellington Cardoso Bonachela; Anuar Antônio Xible
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

9.  Accuracy combining different brands of implants and abutments.

Authors:  María-Fernanda Solá-Ruíz; Eduardo Selva-Otaolaurruchi; Gisela Senent-Vicente; Inés González-de-Cossio; Vicente Amigó-Borrás
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-03-01

10.  In vitro evaluation of leakage at implant-abutment connection of three implant systems having the same prosthetic interface using rhodamine B.

Authors:  Antoine Berberi; Georges Tehini; Khaldoun Rifai; Farah Bou Nasser Eddine; Nabil El Zein; Bassam Badran; Haidar Akl
Journal:  Int J Dent       Date:  2014-05-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.