Literature DB >> 11877619

Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: The impact of fixation level and fixation method under cyclic loading.

Sven U Scheffler1, Norbert P Südkamp, Andreas Göckenjan, Reinhard F G Hoffmann, Andreas Weiler.   

Abstract

PURPOSE: To mechanically test different reconstruction techniques of the anterior cruciate ligament (ACL) under incremental cyclic loading and to evaluate the impact of the level and method of graft fixation on tensile properties of each technique. TYPE OF STUDY: In vitro biomechanical study.
METHODS: Four hamstring and 1 patellar tendon reconstruction techniques were performed on 40 young to middle-aged human cadaveric knees (average age, 39 years). An anterior drawer with increasing loads of 20 N increments was applied at 30 degree of knee flexion. Anatomic, direct interference screw fixation was tested in 2 hamstring and in the patellar tendon groups. Nonanatomic (extracortical) graft anchorage was tested in the remaining 2 hamstring groups with indirect graft fixations on both sides and the combination of indirect tibial and direct femoral fixation. Structural properties were determined throughout the cyclic loading test.
RESULTS: The more anatomic reconstruction techniques provided significantly higher structural properties and smaller loss of fixation compared with nonanatomic, extracortical fixation, with indirect repair on both fixation sites resulting in the lowest structural properties. The tibial fixation site was the weakest link in all of the anatomic reconstructions. Patellar tendon fixation with attached bone blocks in both bone tunnels significantly improved construct stiffness and decreased graft slippage.
CONCLUSIONS: The results of this study suggest that anatomic fixation should be preferred for anchorage of hamstring tendons and linkage materials should be avoided. Direct soft-tissue fixation with interference screws still allows considerable graft slippage, which can be limited by using a bone block or application of a backup or hybrid fixation, especially on the tibial fixation site.

Entities:  

Mesh:

Year:  2002        PMID: 11877619     DOI: 10.1053/jars.2002.30609

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  42 in total

1.  Graft healing in a bone tunnel: bone-attached graft with screw fixation versus bone-free graft with extra-articular suture fixation.

Authors:  Hideo Kawakami; Konsei Shino; Masayuki Hamada; Ken Nakata; Shigeto Nakagawa; Norimasa Nakamura; Yukiyoshi Toritsuka; Hideki Yoshikawa; Takahiro Ochi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-03-24       Impact factor: 4.342

2.  Cryopreservation with glycerol improves the in vitro biomechanical characteristics of human patellar tendon allografts.

Authors:  Lovro Suhodolčan; Miha Brojan; Franc Kosel; Matej Drobnič; Armin Alibegović; Janez Brecelj
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-15       Impact factor: 4.342

3.  Graft-dependent differences in the ligamentization process of anterior cruciate ligament grafts in a sheep trial.

Authors:  Hermann O Mayr; Amelie Stoehr; Markwart Dietrich; Rüdiger von Eisenhart-Rothe; Robert Hube; Senta Senger; Norbert P Suedkamp; Anke Bernstein
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-09-28       Impact factor: 4.342

4.  What is the best femoral fixation of hamstring autografts in anterior cruciate ligament reconstruction?: a meta-analysis.

Authors:  Alexis Colvin; Charu Sharma; Michael Parides; Jonathan Glashow
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

5.  Breakage of bioabsorbable femoral transfix screw after arthroscopic anterior cruciate ligament repair: a report of two cases.

Authors:  A Raviraj; Ashish Anand; K Santosh
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-02-04

6.  Comparison of volumetric bone mineral density in the tibial region of interest for ACL reconstruction.

Authors:  Scott A Klein; John Nyland; David N M Caborn; Yavuz Kocabey; Akbar Nawab
Journal:  Surg Radiol Anat       Date:  2005-10-20       Impact factor: 1.246

7.  Biomechanical comparison of posterior cruciate ligament reconstruction techniques using cyclic loading tests.

Authors:  Yasuharu Hiraga; Yasuyuki Ishibashi; Eiichi Tsuda; Harehiko Tsukada Satoshi Toh
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-07-07       Impact factor: 4.342

8.  Initial fixation strength of a hybrid technique for femoral ACL graft fixation.

Authors:  Andre Weimann; Thore Zantop; Mirco Herbort; Michael Strobel; Wolf Petersen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-08-24       Impact factor: 4.342

9.  Tibial fixation comparison of semitendinosus-bone composite allografts fixed with bioabsorbable screws and bone-patella tendon-bone grafts fixed with titanium screws.

Authors:  Y Kocabey; S Klein; J Nyland; D Caborn
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-07-04       Impact factor: 4.342

10.  Effect of suturing the femoral portion of a four-strand graft during an ACL reconstruction.

Authors:  Lawrence Camarda; Giuseppe Pitarresi; Salvatore Moscadini; Giuseppe Marannano; Antonino Sanfilippo; Michele D'Arienzo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-03-29       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.