Mehmet Coşkun1, Ali Fırat Sarp2, Şebnem Karasu3, Mustafa Fazıl Gelal3, Barış Türkbey4. 1. Department of Radiology, University of Health Sciences Dr. Behçet Uz Child Disease and Pediatric Surgery Training and Research Hospital, İzmir, Turkey. 2. Department of Radiology, Osmangazi University School of Medicine, Eskişehir, Turkey 3. Department of Radiology, İzmir Katip Çelebi University Atatürk Training and Research Hospital, İzmir, Turkey 4. Molecular Imaging Program, National Cancer Institute, National Institutes of Health, Bethesda, Maryland, USA
Abstract
PURPOSE: Although the clinical use of multiparametric prostate magnetic resonance imaging (mpMRI) is increasing, the adherence to parameters for mpMRI, which had been described in the Prostate Imaging-Reporting and Data System version 2 (PI-RADS v2) for an optimum image acquisition is unknown. In this paper, we aimed to determine the compliance with the minimum acceptable technical parameters for prostate mpMRI defined by PI-RADS v2 in tertiary care centers in Turkey. METHODS: We sent a survey to all radiology departments of tertiary referral hospitals in Turkey (n=120) to evaluate their adherence to PI-RADS v2 technical specifications. Statistical analysis was performed using chi-square, Fisher exact, ANOVA, and the Student t tests. The cutoff values for image acquisition times were also determined with receiver operating characteristics (ROC) analysis. P values <0.05 were considered statistically significant. RESULTS: One hundred and eleven clinics responded to our survey (response rate, 92.5%). Prostate MRI was reported to be performed in 61 centers, of which 26 (42.6%) used 3 T (Tesla) scanner while 35 (57.4%) used 1.5 T. The adherence to slice thickness, in-plane phase and frequency resolutions on T2-weighted imaging were 68.9%, 41%, and 9.8%, respectively. The adherence to the same parameters on diffusion-weighted imaging (DWI) were higher compared with T2-weighted imaging (85.2%, 62.3%, and 78.7%, respectively). In comparative analysis, the adherence to slice thickness, field of view (FOV) and in-plane phase resolution on T2-weighted imaging were higher for 3 T compared with 1.5 T scanners (P = 0.004, P = 0.041, and P = 0.001, respectively). T2-weighted imaging acquisition time was significantly longer for the centers that adhered to FOV (P = 0.034) and in-plane T2-weighted imaging phase resolution (P = 0.028). The DWI scan time was significantly longer when they adhered to DWI-FOV (P = 0.014) and b value ≥1400 s/mm2 (P = 0.008). The calculated cutoff of scan times were 220 s in T2-weighted imaging and 312 s in DWI to ensure the compliance with voxel sizes and b value criteria. CONCLUSION: The tertiary referral centers in Turkey did not meet majority of the technical specifications of PI-RADS v2 during prostate MRI acquisition. Awareness to the minimum acceptable technical parameters of mpMRI should be increased to potentially improve the quality of prostate cancer imaging.
PURPOSE: Although the clinical use of multiparametric prostate magnetic resonance imaging (mpMRI) is increasing, the adherence to parameters for mpMRI, which had been described in the Prostate Imaging-Reporting and Data System version 2 (PI-RADS v2) for an optimum image acquisition is unknown. In this paper, we aimed to determine the compliance with the minimum acceptable technical parameters for prostate mpMRI defined by PI-RADS v2 in tertiary care centers in Turkey. METHODS: We sent a survey to all radiology departments of tertiary referral hospitals in Turkey (n=120) to evaluate their adherence to PI-RADS v2 technical specifications. Statistical analysis was performed using chi-square, Fisher exact, ANOVA, and the Student t tests. The cutoff values for image acquisition times were also determined with receiver operating characteristics (ROC) analysis. P values <0.05 were considered statistically significant. RESULTS: One hundred and eleven clinics responded to our survey (response rate, 92.5%). Prostate MRI was reported to be performed in 61 centers, of which 26 (42.6%) used 3 T (Tesla) scanner while 35 (57.4%) used 1.5 T. The adherence to slice thickness, in-plane phase and frequency resolutions on T2-weighted imaging were 68.9%, 41%, and 9.8%, respectively. The adherence to the same parameters on diffusion-weighted imaging (DWI) were higher compared with T2-weighted imaging (85.2%, 62.3%, and 78.7%, respectively). In comparative analysis, the adherence to slice thickness, field of view (FOV) and in-plane phase resolution on T2-weighted imaging were higher for 3 T compared with 1.5 T scanners (P = 0.004, P = 0.041, and P = 0.001, respectively). T2-weighted imaging acquisition time was significantly longer for the centers that adhered to FOV (P = 0.034) and in-plane T2-weighted imaging phase resolution (P = 0.028). The DWI scan time was significantly longer when they adhered to DWI-FOV (P = 0.014) and b value ≥1400 s/mm2 (P = 0.008). The calculated cutoff of scan times were 220 s in T2-weighted imaging and 312 s in DWI to ensure the compliance with voxel sizes and b value criteria. CONCLUSION: The tertiary referral centers in Turkey did not meet majority of the technical specifications of PI-RADS v2 during prostate MRI acquisition. Awareness to the minimum acceptable technical parameters of mpMRI should be increased to potentially improve the quality of prostate cancer imaging.
Authors: Andrew B Rosenkrantz; Sadhna Verma; Peter Choyke; Steven C Eberhardt; Scott E Eggener; Krishnanath Gaitonde; Masoom A Haider; Daniel J Margolis; Leonard S Marks; Peter Pinto; Geoffrey A Sonn; Samir S Taneja Journal: J Urol Date: 2016-06-16 Impact factor: 7.450
Authors: Berrend G Muller; Joanna H Shih; Sandeep Sankineni; Jamie Marko; Soroush Rais-Bahrami; Arvin Koruthu George; Jean J M C H de la Rosette; Maria J Merino; Bradford J Wood; Peter Pinto; Peter L Choyke; Baris Turkbey Journal: Radiology Date: 2015-06-18 Impact factor: 11.105
Authors: Christiane K Kuhl; Robin Bruhn; Nils Krämer; Sven Nebelung; Axel Heidenreich; Simone Schrading Journal: Radiology Date: 2017-07-20 Impact factor: 11.105
Authors: Andrew B Rosenkrantz; Jennifer Hemingway; Danny R Hughes; Richard Duszak; Bibb Allen; Jeffrey C Weinreb Journal: J Urol Date: 2018-02-02 Impact factor: 7.450
Authors: Francesco Giganti; Veeru Kasivisvanathan; Alex Kirkham; Shonit Punwani; Mark Emberton; Caroline M Moore; Clare Allen Journal: Br J Radiol Date: 2021-07-08 Impact factor: 3.039