Literature DB >> 8748482

Flow quantitation with echo-planar phase-contrast velocity mapping: in vitro and in vivo evaluation.

J F Debatin1, D A Leung, S Wildermuth, R Botnar, J Felblinger, G C McKinnon.   

Abstract

We present a multishot echo-planar imaging (EPI) phase-contrast implementation for flow quantitation. The measurement accuracy of this technique was evaluated in vitro and in vivo. A gated eight-shot EPI phase-contrast sequence (TR/TE = 16/7.4, 45 degrees flip angle), with a flow-phase interval of 32 msec and an in-plane resolution of 2 x 2 mm was initially evaluated in a pulsatile flow phantom. Subsequently, EPI phase-contrast flow measurements of the ascending and descending aorta, obtained in 10 volunteers, were compared with flow volume data acquired with a conventional cine phase-contrast sequence (TR/TE = 24/7, 45 degrees flip angle, 48-msec flow-phase interval, 2 x 1 mm in-plane resolution). Comparisons between flow measurements were made using data obtained with the flow probe and cine phase contrast as the standard of reference for in vitro and in vivo measurements, respectively. EPI phase-contrast sequences reduced data acquisition times tenfold compared with cine phase-contrast sequences. EPI phase-contrast flow measurements correlated well with phantom flow (r = .98, slope = 1.1) as well as with aortic cine phase-contrast flow volume determinations (r = .98). A 95% confidence interval of measurement differences between echo-planar and cine phase-contrast imaging, ranging from 2.0 to -1058 mL/min was computed. Ultrafast phase-contrast flow measurements are possible. Multishot EPI phase-contrast imaging provides high measurement accuracy in pulsatile vessels while keeping the image acquisition interval short enough to be accomplished in a comfortable breath-hold.

Entities:  

Mesh:

Year:  1995        PMID: 8748482     DOI: 10.1002/jmri.1880050607

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  9 in total

1.  High temporal resolution phase contrast MRI with multiecho acquisitions.

Authors:  Richard B Thompson; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

2.  MR-velocity mapping in vascular stents to assess peak systolic velocity. In vitro comparison of various stent designs made of Stainless Steel and Nitinol.

Authors:  Jacqueline van Holten; Patrik Kunz; Paul G H Mulder; Peter M T Pattynama; Hildo J Lamb; Lukas C van Dijk
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

Review 3.  Evaluation of intracardiac shunts with cardiac magnetic resonance.

Authors:  Patrick M Colletti
Journal:  Curr Cardiol Rep       Date:  2005-01       Impact factor: 2.931

4.  Real-time phase contrast magnetic resonance imaging for assessment of haemodynamics: from phantom to patients.

Authors:  Julius Traber; Lennart Wurche; Matthias A Dieringer; Wolfgang Utz; Florian von Knobelsdorff-Brenkenhoff; Andreas Greiser; Ning Jin; Jeanette Schulz-Menger
Journal:  Eur Radiol       Date:  2015-07-19       Impact factor: 5.315

5.  Shared velocity encoding: a method to improve the temporal resolution of phase-contrast velocity measurements.

Authors:  Hung-Yu Lin; Jacob A Bender; Yu Ding; Yiu-Cho Chung; Alice M Hinton; Michael L Pennell; Kevin K Whitehead; Subha V Raman; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

6.  Magnetic resonance imaging of ionic currents in solution: the effect of magnetohydrodynamic flow.

Authors:  Mukund Balasubramanian; Robert V Mulkern; William M Wells; Padmavathi Sundaram; Darren B Orbach
Journal:  Magn Reson Med       Date:  2014-10-01       Impact factor: 4.668

7.  Noninvasive quantification of systemic-to-pulmonary collateral flow: a major source of inefficiency in patients with superior cavopulmonary connections.

Authors:  Kevin K Whitehead; Matthew J Gillespie; Matthew A Harris; Mark A Fogel; Jonathan J Rome
Journal:  Circ Cardiovasc Imaging       Date:  2009-07-08       Impact factor: 7.792

8.  Data Quality and Optimal Background Correction Order of Respiratory-Gated k-Space Segmented Spoiled Gradient Echo (SGRE) and Echo Planar Imaging (EPI)-Based 4D Flow MRI.

Authors:  Federica Viola; Petter Dyverfeldt; Carl-Johan Carlhäll; Tino Ebbers
Journal:  J Magn Reson Imaging       Date:  2019-07-22       Impact factor: 4.813

Review 9.  Cardiovascular magnetic resonance phase contrast imaging.

Authors:  Krishna S Nayak; Jon-Fredrik Nielsen; Matt A Bernstein; Michael Markl; Peter D Gatehouse; Rene M Botnar; David Saloner; Christine Lorenz; Han Wen; Bob S Hu; Frederick H Epstein; John N Oshinski; Subha V Raman
Journal:  J Cardiovasc Magn Reson       Date:  2015-08-09       Impact factor: 5.364

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.