Literature DB >> 11835615

Clinical results of percutaneous pelvic surgery. Computer assisted surgery using ultrasound compared to standard fluoroscopy.

J Tonetti1, L Carrat, S Blendea, P Merloz, J Troccaz, S Lavallée, J P Chirossel.   

Abstract

This study presents early results of clinical experience with the application of Computer Assisted Surgery (CAS) to percutaneous iliosacral screwing, with comparison to a historical series of patients treated using percutaneous fluoroscopy. Four patients were instrumented using a CAS system, with 10 screws being inserted. Thirty patients were treated by percutaneous fluoroscopic screwing, with 51 screws being inserted. The follow-up assessment included the following criteria; operative time, parameters of radiation exposure, neurological examination, screw placement evaluation on CT-scan, antalgic drug consumption, pain, Majeed grading, and loosening of implants. In the CAS group, the average radiation time was 0.35 min per patient and 0.14 min per screw. No trajectories outside the bone and no postoperative neurological deficits were found. In the fluoroscopic group, the average radiation time was 1.03 min per patient and 0.6 min per screw. Twelve screws had outside-bone trajectories, and iatrogenic neurological deficits were found in seven patients. The average operative time was 50 min in the CAS group and 35 min in the fluoroscopic group. The present CAS technique shows better placement of iliosacral screws, with no outside-bone trajectories and lower radiation exposure. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11835615     DOI: 10.1002/igs.10010

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  15 in total

1.  Factors influencing the accuracy of iliosacral screw placement in trauma patients.

Authors:  Lars Grossterlinden; Johannes Rueger; Philip Catala-Lehnen; Martin Rupprecht; Wolfgang Lehmann; Andreas Rücker; Daniel Briem
Journal:  Int Orthop       Date:  2010-07-20       Impact factor: 3.075

2.  Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation.

Authors:  D Briem; W Linhart; W Lehmann; P G Begemann; G Adam; U Schumacher; D M Cullinane; J M Rueger; J Windolf
Journal:  Eur Spine J       Date:  2005-07-12       Impact factor: 3.134

3.  [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial].

Authors:  D Briem; J M Rueger; P G C Begemann; Z Halata; T Bock; W Linhart; J Windolf
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

4.  [Percutaneous, 2D-fluoroscopic navigated iliosacral screw placement in the supine position: technique, possibilities, and limits].

Authors:  D Briem; J Windolf; J M Rueger
Journal:  Unfallchirurg       Date:  2007-05       Impact factor: 1.000

5.  [A-mode ultrasonic pointer for navigated pelvic surgery].

Authors:  M Oszwald; M Citak; J Kowal; C Amstutz; D Kendoff; T Kirchhoff; L P Nolte; C Krettek; T Hüfner
Journal:  Unfallchirurg       Date:  2008-03       Impact factor: 1.000

6.  Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure.

Authors:  Jörn Zwingmann; Gerhard Konrad; Elmar Kotter; Norbert P Südkamp; Michael Oberst
Journal:  Clin Orthop Relat Res       Date:  2008-11-26       Impact factor: 4.176

7.  Automatic extraction of bone surfaces from 3D ultrasound images in orthopaedic trauma cases.

Authors:  Ilker Hacihaliloglu; Pierre Guy; Antony J Hodgson; Rafeef Abugharbieh
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-01-01       Impact factor: 2.924

8.  Ultrasound imaging and segmentation of bone surfaces: A review.

Authors:  Ilker Hacihaliloglu
Journal:  Technology (Singap World Sci)       Date:  2017-03-31

9.  Fluoroscopy-based laser guidance system for linear surgical tool insertion depth control.

Authors:  Takehito Doke; Jack T Liang; Shinya Onogi; Yoshikazu Nakajima
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-06-04       Impact factor: 2.924

10.  Bowel preparation prior to percutaneous ilio-sacral screw insertion: is it necessary?

Authors:  H Raza; A Bowe; N Davarinos; M Leonard
Journal:  Eur J Trauma Emerg Surg       Date:  2016-07-04       Impact factor: 3.693

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.