Literature DB >> 11811244

The effect of abduction differences between cup and contralateral acetabular angle on polyethylene component wear.

M Kligman1, H Michael, M Roffman.   

Abstract

One hundred forty-two patients who underwent cemented or uncemented hip replacement were studied radiographically to determine acetabular component wear. Mean duration of follow-up was 58 months (range: 35-92 months). Average linear wear was 0.78 mm (range: 0-1.9 mm), and average wear rate was 0.16 mm/year (range: 0-0.45 mm/year). An increased wear rate per year correlated with a discrepancy >18.3 degrees between contralateral acetabular angle and acetabular cup inclination (P<.005). Statistical analysis revealed no significant correlation between cup inclination and polyethylene wear, which was studied without considering the contralateral hip (P>.3). There was no relationship between polyethylene wear and cup design, weight, and initial polyethylene thickness.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11811244     DOI: 10.3928/0147-7447-20020101-18

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  7 in total

1.  Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty.

Authors:  Jiri Gallo; Vitezslav Havranek; Jana Zapletalova
Journal:  Int Orthop       Date:  2009-02-13       Impact factor: 3.075

2.  Effectiveness of an acetabular positioning device in primary total hip arthroplasty.

Authors:  Douglas E Padgett; Stephen L Hendrix; Timothy S Mologne; Drew A Peterson; Keith A Holley
Journal:  HSS J       Date:  2005-09

3.  The sagittal stem alignment and the stem version clearly influence the impingement-free range of motion in total hip arthroplasty: a computer model-based analysis.

Authors:  Michael Müller; Georg Duda; Carsten Perka; Stephan Tohtz
Journal:  Int Orthop       Date:  2015-07-02       Impact factor: 3.075

4.  High hip center technique using a biconical threaded Zweymüller cup in osteoarthritis secondary to congenital hip disease.

Authors:  Nikolaos A Christodoulou; Konstantinos P Dialetis; Athanasios N Christodoulou
Journal:  Clin Orthop Relat Res       Date:  2010-01-05       Impact factor: 4.176

5.  Acetabular polyethylene wear and acetabular inclination and femoral offset.

Authors:  Nick J Little; Constant A Busch; John A Gallagher; Cecil H Rorabeck; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2009-05-02       Impact factor: 4.176

6.  Catastrophic Failure of the Acetabular Polyethylene Liner in Ceramic-on-Polyethylene Total Hip Arthroplasty.

Authors:  Givenchy Manzano; Rayna A C Levin; Michael B Mayor; Ran Schwarzkopf
Journal:  J Orthop Case Rep       Date:  2014 Apr-Jun

7.  Pelvic Tilt Angle Differences Between Symptom-Free Young Subjects and Elderly Patients Scheduled for THA: The Rationale for Tilt-Adjusted Acetabular Cup Implantation.

Authors:  Carlos J Marques; Tobias Martin; Andrzej Kochman; Adrian Goral; Frank Lampe; Viktor Breul; Josef Kozak
Journal:  Open Orthop J       Date:  2018-08-31
  7 in total