Literature DB >> 11801909

Pseudoenhancement of simple renal cysts: a comparison of single and multidetector helical CT.

Joan P Heneghan1, Audrey L Spielmann, Douglas H Sheafor, Mark A Kliewer, David M DeLong, Rendon C Nelson.   

Abstract

PURPOSE: The purpose of this work was to compare the extent of pseudoenhancement (artifactual increase in measured attenuation of a simple cyst after contrast medium administration) in a phantom model on single detector and multidetector helical CT scanners.
METHOD: The phantom consisted of four water-filled spheres varying in size from 8 to 28 mm, suspended in an aqueous contrast medium bath. Iodine concentration in the bath was varied: 0, 6, 12, and 24 mg/ml corresponding to attenuation values of 0, +108, +180, and +300 HU. The phantom was scanned on single detector and multidetector helical CT scanners during the same session. Collimation (1, 3, and 5 mm) and pitch (1 and 1.5:1, single detector; 3:1 and 6:1, multidetector) were varied at each concentration. All scans were performed at 140 kVp and 170 mA. The region of interest was measured at the center of each sphere. The effects were analyzed using a linear regression model.
RESULTS: The degree of pseudoenhancement was more pronounced with increasing iodine concentration, decreasing cyst size, and wider collimation (all p = 0.0001). Pseudoenhancement was also more marked on the multidetector than the single detector scanner (p = 0.0001). At physiological levels of renal enhancement, the average pseudoenhancement was +18 HU for the single detector versus +23 HU for the multidetector scanner. Variation in pitch had no effect.
CONCLUSION: Pseudoenhancement is greater on a multidetector than a single detector helical CT scanner and may exceed 20 HU at physiological levels of renal enhancement.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11801909     DOI: 10.1097/00004728-200201000-00013

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  8 in total

1.  Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms.

Authors:  Izuru Matsuda; Masaaki Akahane; Jiro Sato; Masaki Katsura; Shigeru Kiryu; Naoki Yoshioka; Akira Kunimatsu; Kenji Ino; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2011-12-02       Impact factor: 2.374

2.  Renal cyst pseudoenhancement at multidetector CT: what are the effects of number of detectors and peak tube voltage?

Authors:  Zhen J Wang; Fergus V Coakley; Yanjun Fu; Bonnie N Joe; Sven Prevrhal; Luis A Landeras; Emma M Webb; Benjamin M Yeh
Journal:  Radiology       Date:  2008-07-15       Impact factor: 11.105

3.  Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study.

Authors:  C L Brown; R P Hartman; O P Dzyubak; N Takahashi; A Kawashima; C H McCollough; M R Bruesewitz; A M Primak; J G Fletcher
Journal:  Eur Radiol       Date:  2009-01-20       Impact factor: 5.315

4.  In vivo predictors of renal cyst pseudoenhancement at 120 kVp.

Authors:  Jeet Patel; Matthew S Davenport; Shokoufeh Khalatbari; Richard H Cohan; James H Ellis; Joel F Platt
Journal:  AJR Am J Roentgenol       Date:  2014-02       Impact factor: 3.959

5.  Informatics in radiology: Electronic cleansing for noncathartic CT colonography: a structure-analysis scheme.

Authors:  Wenli Cai; Hiroyuki Yoshida; Michael E Zalis; Janne Johannes Näppi; Gordon J Harris
Journal:  Radiographics       Date:  2010-03-10       Impact factor: 5.333

6.  Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements.

Authors:  Giorgio Ascenti; Achille Mileto; Bernhard Krauss; Michele Gaeta; Alfredo Blandino; Emanuele Scribano; Nicola Settineri; Silvio Mazziotti
Journal:  Eur Radiol       Date:  2013-03-12       Impact factor: 5.315

7.  The characterization of small hypoattenuating renal masses on contrast-enhanced CT.

Authors:  Neesha S Patel; Liina Poder; Zhen J Wang; Benjamin M Yeh; Aliya Qayyum; Hua Jin; Fergus V Coakley
Journal:  Clin Imaging       Date:  2009 Jul-Aug       Impact factor: 1.605

8.  Effect of thin overlapping reconstruction on the attenuation of small (< or = 3 cm) renal cysts in the nephrographic phase of MDCT: a phantom study.

Authors:  Sun Ho Kim; Seung Hyup Kim
Journal:  Korean J Radiol       Date:  2006 Oct-Dec       Impact factor: 3.500

  8 in total