Literature DB >> 11800133

Superthreshold behavior and threshold estimates of ultrasound-induced lung hemorrhage in adult rats: role of beamwidth.

W D O'Brien1, D G Simpson, L A Frizzell, J F Zachary.   

Abstract

It is well documented that ultrasound-induced lung hemorrhage can occur in mice, rats, rabbits, pigs, and monkeys. The objective of this study was to assess the role of the ultrasound beamwidth (beam diameter incident on the lung surface) on lesion threshold and size. A total of 144 rats were randomly exposed to pulsed ultrasound at three exposure levels and four beamwidths (12 rats per group). The three in situ peak rarefactional pressures were about 5, 7.5, and 10 MPa. The four 19-mm-diameter focused transducers had measured pulse-echo -6-dB focal beamwidths of 470 microm (2.8 MHz; f/1), 930 microm (2.8 MHz; f/2), 310 microm (5.6 MHz; f/1), and 510 microm (5.6 MHz; f/2). Exposure durations were 10 s, pulse repetition frequencies were 1 kHz, and pulse durations were 1.3 micros (2.8 MHz; f/1), 1.2 micros (2.8 MHz; f/2), 0.8 micros (5.6 MHz; f/1) and 1.1 micros (5.6 MHz; f/2). The lesion surface area and depth were measured for each rat as well as the percentage of rats with lesions per group. Logistic regression analysis and Gaussian-Tobit analysis methods were used to analyze the data. The effects of in situ peak rarefactional pressure and beamwidth were highly significant, but ultrasonic frequency was not significant. In addition, the estimated interaction between in situ peak rarefactional pressure and beamwidth was positive and highly significant. The ultrasound beamwidth incident on the lung surface was shown to strongly affect the percentage and size of ultrasound-induced lung hemorrhage lesions. Even though ultrasonic frequency was an experimental variable, it was not shown to affect the lesion percentage or size.

Entities:  

Mesh:

Year:  2001        PMID: 11800133     DOI: 10.1109/58.971723

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  14 in total

1.  Vascular lesions and s-thrombomodulin concentrations from auricular arteries of rabbits infused with microbubble contrast agent and exposed to pulsed ultrasound.

Authors:  James F Zachary; James P Blue; Rita J Miller; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

2.  Threshold estimation of ultrasound-induced lung hemorrhage in adult rabbits and comparison of thresholds in mice, rats, rabbits and pigs.

Authors:  William D O'Brien; Yan Yang; Douglas G Simpson; Leon A Frizzell; Rita J Miller; James P Blue; James F Zachary
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

3.  Lesions of ultrasound-induced lung hemorrhage are not consistent with thermal injury.

Authors:  James F Zachary; James P Blue; Rita J Miller; Brian J Ricconi; J Gary Eden; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

Review 4.  Ultrasound-biophysics mechanisms.

Authors:  William D O'Brien
Journal:  Prog Biophys Mol Biol       Date:  2006-08-08       Impact factor: 3.667

5.  Evaluation of the threshold for lung hemorrhage by diagnostic ultrasound and a proposed new safety index.

Authors:  Charles C Church; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2007-03-26       Impact factor: 2.998

6.  Contrast ultrasound imaging of the aorta alters vascular morphology and circulating von Willebrand factor in hypercholesterolemic rabbits.

Authors:  Brendon W Smith; Douglas G Simpson; Sandhya Sarwate; Rita J Miller; James P Blue; Alexander Haak; William D O'Brien; John W Erdman
Journal:  J Ultrasound Med       Date:  2012-05       Impact factor: 2.153

7.  Superthreshold behavior of ultrasound-induced lung hemorrhage in adult rats: role of pulse repetition frequency and pulse duration.

Authors:  William D O'Brien; Douglas G Simpson; Leon A Frizzell; James F Zachary
Journal:  J Ultrasound Med       Date:  2006-07       Impact factor: 2.153

8.  Pulmonary Capillary Hemorrhage Induced by Fixed-Beam Pulsed Ultrasound.

Authors:  Douglas L Miller; Chunyan Dou; Krishnan Raghavendran
Journal:  Ultrasound Med Biol       Date:  2015-04-29       Impact factor: 2.998

9.  Ultrasonic imaging: safety considerations.

Authors:  Gail Ter Haar
Journal:  Interface Focus       Date:  2011-05-25       Impact factor: 3.906

10.  Dependence of thresholds for pulmonary capillary hemorrhage on diagnostic ultrasound frequency.

Authors:  Douglas L Miller; Chunyan Dou; Krishnan Raghavendran
Journal:  Ultrasound Med Biol       Date:  2015-03-03       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.