Literature DB >> 14991419

[Radiation exposure and 3 dimensional imaging options of SIREMOBIL Iso-C(3D) for planning surgical dental interventions].

M Heiland1, D Schulze, S Flinzberg, H Thurmann, U Rother, R Schmelzle.   

Abstract

BACKGROUND: Preoperative dental X-ray diagnostics of multimorbid, non compliant patients requiring dental surgery are often insufficient. The SIREMOBIL Iso-C(3D) has made intraoperative 3D imaging available, even for the facial skeleton. This modality was used intraoperatively in two patients referred for surgical dental treatment. Furthermore, radiation exposure of the SIREMOBIL Iso-C(3D), an orthopantomography and a complete dental status was compared.
MATERIAL AND METHODS: An Alderson-Rando phantom was exposed to ten cycles of the SIREMOBIL Iso-C(3D) using the fast mode (50 projections). In comparison 28 panoramic views of an Orthophos and 10 sets of 14 dental images using the Oralix DC with a quadrate mask were applied. Twenty-five anatomically defined TLD positions were analyzed. Furthermore, SIREMOBIL Iso-C(3D) was used in one patient by performing 100 projections and in a second patient by performing 50 projections. After DICOM-import in eFilm, axial, coronal, and sagittal reconstructions were evaluated by five examiners regarding defined criteria.
RESULTS: The radiation exposure level of the SIREMOBIL Iso-C(3D) was lower than in the complete dental status and only slightly higher in comparison with the orthopantomography, although the system requires the highest number of single projections. Quantitative evaluation of the visualization and recognition of defined structures proved to be very good and good in most points. However, limitations of the system became obvious regarding apical processes.
CONCLUSION: Because of the dosimetry results and the visualization of the relevant structures, in patients for whom preoperative images cannot sufficiently be performed, the intraoperative use of the SIREMOBIL Iso-C(3D) as a base examination is justified.

Entities:  

Mesh:

Year:  2004        PMID: 14991419     DOI: 10.1007/s10006-003-0521-9

Source DB:  PubMed          Journal:  Mund Kiefer Gesichtschir        ISSN: 1432-9417


  18 in total

1.  Radiation dose in dental radiology.

Authors:  M Cohnen; J Kemper; O Möbes; J Pawelzik; U Mödder
Journal:  Eur Radiol       Date:  2001-06-01       Impact factor: 5.315

2.  [Radiation exposure of the head, midface and pelvis in multi-slice CT (MSCT): comparison with single-slice CT (SSCT)].

Authors:  U Wedegärtner; H Thurmann; R Schmidt; G Adam
Journal:  Rofo       Date:  2003-02

3.  In vivo, thyroid and lens surface exposure with spiral and conventional computed tomography in dental implant radiography.

Authors:  J Bianchi; W Goggins; M Rudolph
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2000-08

4.  Three-dimensional CT with a modified C-arm image intensifier: feasibility.

Authors:  Ulrich Linsenmaier; Clemens Rock; Ekkehard Euler; Stefan Wirth; Roland Brandl; Dorothea Kotsianos; Wolf Mutschler; Klaus Jürgen Pfeifer
Journal:  Radiology       Date:  2002-07       Impact factor: 11.105

5.  3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil Iso-C3D).

Authors:  M Heiland; D Schulze; G Adam; R Schmelzle
Journal:  Dentomaxillofac Radiol       Date:  2003-01       Impact factor: 2.419

6.  A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results.

Authors:  P Mozzo; C Procacci; A Tacconi; P T Martini; I A Andreis
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

7.  [Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): Comparison with plain films and spiral CT].

Authors:  D Kotsianos; C Rock; S Wirth; U Linsenmaier; R Brandl; T Fischer; E Euler; W Mutschler; K J Pfeifer; M Reiser
Journal:  Rofo       Date:  2002-01

8.  Intraoperative computed tomography with the mobile CT Tomoscan M during surgical treatment of orbital fractures.

Authors:  F Hoelzle; M Klein; O Schwerdtner; T Lueth; J Albrecht; N Hosten; R Felix; J Bier
Journal:  Int J Oral Maxillofac Surg       Date:  2001-02       Impact factor: 2.789

9.  [3-dimensional imaging possibilities of thhe mid-face area using digital volume tomography based on a daver study of angle stable osteosynthesis].

Authors:  S Flinzberg; R Schmelzle; D Schulze; U Rother; M Heiland
Journal:  Mund Kiefer Gesichtschir       Date:  2003-08-15

10.  A comparison of conventional panoramic radiographs with volumetric computed tomography images in the preoperative assessment of impacted mandibular third molars.

Authors:  J Pawelzik; M Cohnen; R Willers; J Becker
Journal:  J Oral Maxillofac Surg       Date:  2002-09       Impact factor: 1.895

View more
  1 in total

1.  [Clinical experience with the Siremobil Iso-C(3D) imaging system in pelvic surgery].

Authors:  U Stöckle; B König; A Schäffler; T Zschernack; N P Haas
Journal:  Unfallchirurg       Date:  2006-01       Impact factor: 1.000

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.