A comparative evaluation of the tissue responses associated with polymeric implants in the rat and mouse.

Kameha R Kidd1, Donny B Dal Ponte, Robert S Kellar, Stuart K Williams.   

Abstract

End product application is an important consideration when evaluating a material in an in vivo setting (Didisheim, Cardiovasc Pathol 1993;2:1S-2S). Small animal models allow high through-put evaluation of biocompatability. Previous preclinical evaluations have often used a rat subcutaneous model for the characterization of material-tissue interaction. Recent advances in genetic manipulation have provided mouse models with selective expression of a wide range of critical proteins. The rat model does not have many of the resources (i.e., knockouts, SCID, nude) that are present in mouse strains. The availability of these mice provides a resource to delineate the mechanisms regulating the healing associated with implants. However, before the mouse models can be used, they must be validated with respect to their ability to accurately assess tissue responses to materials. In this study the tissue responses after the implantation of expanded polytetrafluoroethylene (ePTFE) were compared between rat and mouse. Discs of ePTFE (30-microm internodal distance) were implanted in subcutaneous and epididymal fat tissue of rats (Sprague-Dawley) and mice (129-SVJ). After 5 weeks the samples were removed and evaluated for vascular density, inflammation, and fibrous encapsulation. No difference in the vessel density was observed within the peri-implant subcutaneous and adipose tissue or within the porous material. However, a significant difference was found in the number of activated macrophages and giant cells between these two species. Implants in the rat exhibited greater numbers of activated inflammatory cells in the peri-implant tissue. The data indicate that the mouse and rat provide a comparable model for evaluating angiogenesis and neovascularization associated with synthetic porous implants. Copyright 2001 John Wiley & Sons, Inc. J Biomed Mater Res 59: 682-689, 2002

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11774330     DOI: 10.1002/jbm.10032

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  8 in total

Review 1.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and the foreign body response-part I: theoretical framework.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

2.  Encapsulation of ePTFE in prevascularized collagen leads to peri-implant vascularization with reduced inflammation.

Authors:  Gabriel Gruionu; Alice L Stone; Mark A Schwartz; James B Hoying; Stuart K Williams
Journal:  J Biomed Mater Res A       Date:  2010-12-01       Impact factor: 4.396

3.  Host response to xenograft ECM implantation is not different between the shoulder and body wall sites in the rat model.

Authors:  Diane R Leigh; Mena Mesiha; Andrew R Baker; Esteban Walker; Kathleen A Derwin
Journal:  J Orthop Res       Date:  2012-05-22       Impact factor: 3.494

4.  Effect of implantation site and injury condition on host response to human-derived fascia lata ECM in a rat model.

Authors:  Diane R Leigh; Andrew R Baker; Mena Mesiha; E Rene Rodriguez; Carmela D Tan; Esteban Walker; Kathleen A Derwin
Journal:  J Orthop Res       Date:  2011-08-19       Impact factor: 3.494

Review 5.  Extracellular matrix-based biomaterial scaffolds and the host response.

Authors:  Joseph M Aamodt; David W Grainger
Journal:  Biomaterials       Date:  2016-02-03       Impact factor: 12.479

6.  Microvascular guidance: a challenge to support the development of vascularised tissue engineering construct.

Authors:  Irza Sukmana
Journal:  ScientificWorldJournal       Date:  2012-04-24

7.  The Effect of Diclofenac Sodium-Loaded PLGA Rods on Bone Healing and Inflammation: A Histological and Histomorphometric Study in the Femur of Rats.

Authors:  Karoline M Reich; Petrus Viitanen; Ehsanul Hoque Apu; Stefan Tangl; Nureddin Ashammakhi
Journal:  Micromachines (Basel)       Date:  2020-12-12       Impact factor: 2.891

Review 8.  Advanced strategies to thwart foreign body response to implantable devices.

Authors:  Simone Capuani; Gulsah Malgir; Corrine Ying Xuan Chua; Alessandro Grattoni
Journal:  Bioeng Transl Med       Date:  2022-03-02
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.