Literature DB >> 11764031

Automated seed detection and three-dimensional reconstruction. I. Seed localization from fluoroscopic images or radiographs.

D Tubic1, A Zaccarin, J Pouliot, L Beaulieu.   

Abstract

An automated procedure for the detection of the position and the orientation of radioactive seeds on fluoroscopic images or scanned radiographs is presented. The extracted positions of seed centers and the orientations are used for three-dimensional reconstruction of permanent prostate implants. The extraction procedure requires several steps: correction of image intensifier distortions, normalization, background removal, automatic threshold selection, thresholding, and finally, moment analysis and classification of the connected components. The algorithm was tested on 75 fluoroscopic images. The results show that, on average, 92% of the seeds are detected automatically. The orientation is found with an error smaller than 50 for 75% of the seeds. The orientation of overlapping seeds (10%) should be considered as an estimate at best. The image processing procedure can also be used for seed or catheter detection in CT images, with minor modifications.

Mesh:

Year:  2001        PMID: 11764031     DOI: 10.1118/1.1414308

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis.

Authors:  Ehsan Dehghan; Mehdi Moradi; Xu Wen; Danny French; Julio Lobo; W James Morris; Septimiu E Salcudean; Gabor Fichtinger
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  INTENSITY-BASED REGISTRATION OF PROSTATE BRACHYTHERAPY IMPLANTS AND ULTRASOUND.

Authors:  Z Karimaghaloo; G Fichtinger; D G Gobbi; E C Burdette; R N Rohling; P Abolmaesumi
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2008-06-13

3.  Preliminary study of correction of original metal artifacts due to 1-125 seeds in postimplant dosimetry for prostate permanent implant brachytherapy.

Authors:  Yutaka Takahashi; Shinichiro Mori; Takuyo Kozuka; Kotaro Gomi; Takayuki Nose; Takatoshi Tahara; Masahiko Oguchi; Takashi Yamashita
Journal:  Radiat Med       Date:  2006-02

4.  Automatic image-to-world registration based on x-ray projections in cone-beam CT-guided interventions.

Authors:  N M Hamming; M J Daly; J C Irish; J H Siewerdsen
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

5.  Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

6.  Automatic seed picking for brachytherapy postimplant validation with 3D CT images.

Authors:  Guobin Zhang; Qiyuan Sun; Shan Jiang; Zhiyong Yang; Xiaodong Ma; Haisong Jiang
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-06-22       Impact factor: 2.924

7.  Automatic segmentation of seeds and fluoroscope tracking (FTRAC) fiducial in prostate brachytherapy x-ray images.

Authors:  Nathanael Kuo; Junghoon Lee; Anton Deguet; Danny Song; E Clif Burdette; Jerry Prince
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-02-23

8.  Automatic segmentation of radiographic fiducial and seeds from X-ray images in prostate brachytherapy.

Authors:  Nathanael Kuo; Anton Deguet; Danny Y Song; Everette C Burdette; Jerry L Prince; Junghoon Lee
Journal:  Med Eng Phys       Date:  2011-07-29       Impact factor: 2.242

9.  Clinical application and validation of an iterative forward projection matching algorithm for permanent brachytherapy seed localization from conebeam-CT x-ray projections.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

10.  Prostate brachytherapy seed reconstruction with Gaussian blurring and optimal coverage cost.

Authors:  Junghoon Lee; Xiaofeng Liu; Ameet K Jain; Danny Y Song; Everette C Burdette; Jerry L Prince; Gabor Fichtinger
Journal:  IEEE Trans Med Imaging       Date:  2009-07-14       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.