Literature DB >> 11701795

Revision of a cemented acetabular component to a cementless acetabular component. A ten to fourteen-year follow-up study.

J E Templeton1, J J Callaghan, D D Goetz, P M Sullivan, R C Johnston.   

Abstract

BACKGROUND: Although cementless acetabular components are routinely used in revision hip surgery, few investigators have evaluated the retention and efficacy of these components in the long term. In the current study, the clinical and radiographic outcomes of a series of arthroplasties performed by one surgeon with a cementless acetabular component were assessed at a minimum of ten years.
METHODS: From 1986 through 1988, sixty-one consecutive revision total hip arthroplasties were performed in fifty-five patients because of aseptic failure of one or both components of a prosthesis in which both components had been cemented. Twenty-eight patients (thirty-two hips) were alive at a mean of 12.9 years (range, 11.5 to 14.3 years) after the operation. In all of the patients, the acetabular component was revised to a porous-coated Harris-Galante component inserted without cement, and the femoral component was revised to an Iowa component affixed with contemporary cementing techniques. The hips were evaluated clinically and radiographically at a minimum of ten years subsequent to the index revision. No hips were lost to follow-up.
RESULTS: None of the acetabular components required revision because of aseptic loosening. Two hips (3%) demonstrated radiographic evidence of aseptic loosening of the acetabular component. The polyethylene liner was exchanged during the follow-up period in eight hips.
CONCLUSION: After a minimum of ten years of follow-up, cementless acetabular fixation in revision hip arthroplasty had produced durable results that were markedly better than those reported for acetabular fixation with cement.

Entities:  

Mesh:

Year:  2001        PMID: 11701795     DOI: 10.2106/00004623-200111000-00014

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  19 in total

1.  [Treatment of acetabular defects with the trabecular metal revision system].

Authors:  G I Wassilew; V Janz; C Perka; M Müller
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

2.  Effect of design on the initial stability of press-fit cups in the presence of acetabular rim defects: experimental evaluation of the effect of adding circumferential fins.

Authors:  Wolfgang O Huber; Philip C Noble
Journal:  Int Orthop       Date:  2013-11-22       Impact factor: 3.075

Review 3.  Systematic review on outcomes of acetabular revisions with highly-porous metals.

Authors:  Samik Banerjee; Kimona Issa; Bhaveen H Kapadia; Robert Pivec; Harpal S Khanuja; Michael A Mont
Journal:  Int Orthop       Date:  2013-11-01       Impact factor: 3.075

4.  Do tantalum and titanium cups show similar results in revision hip arthroplasty?

Authors:  S Mehdi Jafari; Benjamin Bender; Catelyn Coyle; Javad Parvizi; Peter F Sharkey; William J Hozack
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

Review 5.  Cementless acetabular revision: past, present, and future. Revision total hip arthroplasty: the acetabular side using cementless implants.

Authors:  Luis Pulido; Sridhar R Rachala; Miguel E Cabanela
Journal:  Int Orthop       Date:  2011-01-14       Impact factor: 3.075

6.  Acetabular Defect Reconstruction with Trabecular Metal Augments: Study with Minimum One-year Follow-up.

Authors:  Chirayu Dwivedi; Sandeep Gokhale; Hyun Gon Khim; Jeon Keon Oh; Won Yong Shon
Journal:  Hip Pelvis       Date:  2017-09-06

Review 7.  Acetabular reinforcement rings associated with allograft for severe acetabular defects.

Authors:  Emmanuel Gibon; Luc Kerboull; Jean-Pierre Courpied; Moussa Hamadouche
Journal:  Int Orthop       Date:  2018-09-13       Impact factor: 3.075

8.  Continued good results with modular trabecular metal augments for acetabular defects in hip arthroplasty at 7 to 11 years.

Authors:  Michael R Whitehouse; Bassam A Masri; Clive P Duncan; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

Review 9.  Acetabular reconstruction in revision total hip arthroplasty.

Authors:  George W Fryhofer; Sireesh Ramesh; Neil P Sheth
Journal:  J Clin Orthop Trauma       Date:  2019-12-02

10.  Acetabular revision with metal mesh, impaction bone grafting, and a cemented cup.

Authors:  Martín A Buttaro; Fernando Comba; Rodolfo Pusso; Francisco Piccaluga
Journal:  Clin Orthop Relat Res       Date:  2008-08-13       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.