Literature DB >> 11698630

Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions.

K M Yeow1, L C See, K W Lui, M C Lin, T C Tsao, K F Ng, H P Liu.   

Abstract

PURPOSE: To evaluate risk factors for pneumothorax and bleeding after computed tomography (CT)-guided percutaneous coaxial cutting needle biopsy of lung lesions.
MATERIALS AND METHODS: This study involved 117 consecutive patients with 117 intrapulmonary lesions. Statistical analysis of factors related to patient characteristics, lung lesions, and biopsy technique was performed to determine possible contribution to the occurrence of pneumothorax and bleeding. Interactions between related factors were considered to prevent colinearity.
RESULTS: Pneumothorax occurred in 12% (14 of 117) of patients. Needle aspiration of two moderate asymptomatic pneumothoraces were performed; there was no chest tube insertion. Lesion depth (P =.0097), measured from the pleural puncture site to the edge of the intrapulmonary lesion along the needle path, was the single significant predictor of pneumothorax. The highest risk of pneumothorax occurred in subpleural lesions 2 cm or shorter in depth (this represented 33% of lung lesions but caused 71% of all pneumothoraces; OR = 7.1; 95% CI, 1.3-50.8). Bleeding presented as lung parenchyma hemorrhage and hemoptysis in 30 patients (26%). Hemoptysis occurred in four patients (3%). Univariate analysis identified lesion depth (P <.0001), lesion size (P <.015), and pathology type (P =.007) as risk factors for bleeding. Multivariate logistic regression analysis identified lesion depth as the most important risk factor, with the highest bleeding risk for lesions more than 2 cm deep (14% of lesions caused 46% of all bleeding; OR = 17.3; 95% CI, 3.3-121.4).
CONCLUSIONS: In CT-guided coaxial cutting needle biopsy, lesion depth is the single predictor for risk of pneumothorax, which occurs at the highest rate in subpleural lesions. Increased risk of bleeding occurs in lesions deeper than 2 cm.

Entities:  

Mesh:

Year:  2001        PMID: 11698630     DOI: 10.1016/s1051-0443(07)61556-5

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  50 in total

1.  Atrial fibrillation and pneumothorax after transthoracic needle lung biopsy.

Authors:  Alexander Liu; Iain Southern; Edward Nicol
Journal:  BMJ Case Rep       Date:  2012-01-18

2.  Guidelines for radiologically guided lung biopsy.

Authors:  A Manhire; M Charig; C Clelland; F Gleeson; R Miller; H Moss; K Pointon; C Richardson; E Sawicka
Journal:  Thorax       Date:  2003-11       Impact factor: 9.139

3.  Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses.

Authors:  Siri Lagethon Heck; Peter Blom; Audun Berstad
Journal:  Eur Radiol       Date:  2006-03-16       Impact factor: 5.315

4.  Transthoracic fine-needle aspiration biopsy of the lungs using a C-arm cone-beam CT system: diagnostic accuracy and post-procedural complications.

Authors:  W J Lee; S Chong; J S Seo; H J Shim
Journal:  Br J Radiol       Date:  2011-10-18       Impact factor: 3.039

Review 5.  Common complications of nonvascular percutaneous thoracic interventions: diagnosis and management.

Authors:  Azzam Khankan; Shireen Sirhan; Fadi Aris
Journal:  Semin Intervent Radiol       Date:  2015-06       Impact factor: 1.513

6.  Assessment of MR imaging during one-lung flooding in a large animal model.

Authors:  Frank Wolfram; Daniel Güllmar; Joachim Böttcher; Harald Schubert; Sabine Bischoff; Jürgen R Reichenbach; Thomas Günther Lesser
Journal:  MAGMA       Date:  2019-06-01       Impact factor: 2.310

Review 7.  Transthoracic needle aspiration in solitary pulmonary nodule.

Authors:  Wen Yang; Hongli Jiang; Ali Nawaz Khan; Carolyn Allen; Luca Bertolaccini; Tangfeng Lv; Yong Song
Journal:  Transl Lung Cancer Res       Date:  2017-02

Review 8.  The Pursuit of Noninvasive Diagnosis of Lung Cancer.

Authors:  Thomas Atwater; Christine M Cook; Pierre P Massion
Journal:  Semin Respir Crit Care Med       Date:  2016-10-12       Impact factor: 3.119

9.  CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance.

Authors:  Ga Ram Kim; Jin Hur; Sang Min Lee; Hye-Jeong Lee; Yoo Jin Hong; Ji Eun Nam; Hua Sun Kim; Young Jin Kim; Byoung Wook Choi; Tae Hoon Kim; Kyu Ok Choe
Journal:  Eur Radiol       Date:  2010-08-22       Impact factor: 5.315

10.  Accuracy of CT-guided transthoracic needle biopsy of lung lesions: factors affecting diagnostic yield.

Authors:  A M Priola; S M Priola; A Cataldi; L Errico; M Di Franco; P Campisi; L Molinaro; V Marci; S Novello; C Fava
Journal:  Radiol Med       Date:  2007-12-13       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.