Literature DB >> 11585216

Fluoroscopic study of tumor motion due to breathing: facilitating precise radiation therapy for lung cancer patients.

Q S Chen1, M S Weinhous, F C Deibel, J P Ciezki, R M Macklis.   

Abstract

Target motion due to breathing is one of the major obstacles in dose escalation of radiation therapy to some tumors in the thoracoabdominal region. The development of beam gating or target motion tracking techniques provides a possibility to reduce normal tissue volume in a treatment field. Tumor motion monitoring in those techniques plays a crucial role, but has not yet been adequately explored. This paper reports our preliminary investigation on breath introduced tumor motion. Tumor locations and motion properties were determined from digitized fluoroscopic videos acquired during patient simulation. Image distortion due to irregularities in the imaging chain, such as the pincushion distortion, was corrected with a polynomial unwarping method. Temporal Fourier transformation of the fluoroscopic video was introduced to convert the motion information over time to a static view of a motion field, in which regions with different motion ranges can be directly measured. Patient breathing patterns vary from patient to patient and so does the kinematic behavior of individual tumors. In order to evaluate the feasibility for tracking internal target motion with nonionizing-radiation techniques, motion patterns between internal targets and external radio opaque markers placed on patient's chest during fluoroscopic video acquisition were compared. For some patients, significant motion phase discrepancies between an internal target and an external marker have been observed. Quantitative measurements are reported. These results will be useful in the design of a motion tracking or gated radiotherapy system.

Entities:  

Mesh:

Year:  2001        PMID: 11585216     DOI: 10.1118/1.1398037

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  A novel technique for markerless, self-sorted 4D-CBCT: feasibility study.

Authors:  Irina Vergalasova; Jing Cai; Fang-Fang Yin
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

2.  Sequential dual-energy subtraction technique with a dynamic flat-panel detector (FPD): primary study for image-guided radiation therapy (IGRT).

Authors:  Rie Tanaka; Shigeru Sanada; Takeshi Matsui; Norio Hayashi; Osamu Matsui
Journal:  Radiol Phys Technol       Date:  2008-04-10

Review 3.  A review of intensity-modulated radiation therapy.

Authors:  Laurie E Gaspar; Meisong Ding
Journal:  Curr Oncol Rep       Date:  2008-07       Impact factor: 5.075

4.  Changes in chest wall thickness during four-dimensional CT in particle lung treatment planning.

Authors:  S Mori; N Yamamoto; M Nakajima; M Baba
Journal:  Br J Radiol       Date:  2011-08       Impact factor: 3.039

5.  Evaluation of a template-based algorithm for markerless lung tumour localization on single- and dual-energy kilovoltage images.

Authors:  Alec M Block; Rakesh Patel; Murat Surucu; Matthew M Harkenrider; John C Roeske
Journal:  Br J Radiol       Date:  2016-10-12       Impact factor: 3.039

Review 6.  Current status and future prospects of multi-dimensional image-guided particle therapy.

Authors:  Shinichiro Mori; Silvan Zenklusen; Antje-Christin Knopf
Journal:  Radiol Phys Technol       Date:  2013-02-19

Review 7.  Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging.

Authors:  Rie Tanaka
Journal:  Radiol Phys Technol       Date:  2016-06-13

8.  Tradeoffs for assuming rigid target motion in Mlc-based real time target tracking radiotherapy: a dosimetric and radiobiological analysis.

Authors:  T Roland; C Shi; Y Liu; R Crownover; P Mavroidis; N Papanikolaou
Journal:  Technol Cancer Res Treat       Date:  2010-04

9.  Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: a feasibility study.

Authors:  Rajesh Regmi; D Michael Lovelock; Margie Hunt; Pengpeng Zhang; Hai Pham; Jianping Xiong; Ellen D Yorke; Karyn A Goodman; Andreas Rimner; Hassan Mostafavi; Gig S Mageras
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

10.  Effect of novel amplitude/phase binning algorithm on commercial four-dimensional computed tomography quality.

Authors:  Jeffrey R Olsen; Wei Lu; James P Hubenschmidt; Michelle M Nystrom; Paul Klahr; Jeffrey D Bradley; Daniel A Low; Parag J Parikh
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-11-26       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.