Literature DB >> 20821140

Sequential dual-energy subtraction technique with a dynamic flat-panel detector (FPD): primary study for image-guided radiation therapy (IGRT).

Rie Tanaka1, Shigeru Sanada, Takeshi Matsui, Norio Hayashi, Osamu Matsui.   

Abstract

A sequential dual-energy subtraction technique for image-guided radiation therapy (IGRT) was developed. Here, we report on a computerized method for creating sequential soft-tissue images and the accuracy of tracking targets on the images obtained, in comparison to conventional fluoroscopic images. Two sets of sequential chest images during respiration of a normal subject were obtained with X-rays of different energy separately with a flat-panel detector (FPD). Sequential soft-tissue images were created from the two sets of sequential images consisting of real-time images and reference template images, respectively. The creation of sequential soft-tissue images consisted of three steps: one-to-one image correspondence of the two sequential images, image registration, and image subtraction in each frame. Motion tracking of lung vessels was then performed by the template-matching technique. For evaluation of the accuracy of motion tracking on the sequential soft-tissue images, the results were compared with those on the original sequential images. Sequential soft-tissue images provided more accurate tracking than the original images (P < 0.01). There was no significant error throughout all frames in the soft-tissue images, whereas the rib shadow introduced a tracking error in the original images. The maximum errors were 4.1 +/- 0.3 mm in the sequential soft-tissue images and 28.1 +/- 20.0 mm in the original images. In conclusion, sequential soft-tissue images were helpful for tracking of a target affected by respiratory motion. Dual-energy subtraction has the potential to improve the accuracy of IGRT without implanted markers.

Entities:  

Mesh:

Year:  2008        PMID: 20821140     DOI: 10.1007/s12194-008-0021-6

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  20 in total

1.  The use of active breathing control (ABC) to reduce margin for breathing motion.

Authors:  J W Wong; M B Sharpe; D A Jaffray; V R Kini; J M Robertson; J S Stromberg; A A Martinez
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-07-01       Impact factor: 7.038

2.  Iterative image warping technique for temporal subtraction of sequential chest radiographs to detect interval change.

Authors:  T Ishida; S Katsuragawa; K Nakamura; H MacMahon; K Doi
Journal:  Med Phys       Date:  1999-07       Impact factor: 4.071

3.  Feasibility of real time dual-energy imaging based on a flat panel detector for coronary artery calcium quantification.

Authors:  Tong Xu; Justin L Ducote; Jerry T Wong; Sabee Molloi
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

4.  Improvement of detection in computed radiography by new single-exposure dual-energy subtraction.

Authors:  W Ito; K Shimura; N Nakajima; M Ishida; H Kato
Journal:  J Digit Imaging       Date:  1993-02       Impact factor: 4.056

5.  Synchronized moving aperture radiation therapy (SMART): improvement of breathing pattern reproducibility using respiratory coaching.

Authors:  Toni Neicu; Ross Berbeco; John Wolfgang; Steve B Jiang
Journal:  Phys Med Biol       Date:  2006-01-19       Impact factor: 3.609

6.  Design of 4D treatment planning target volumes.

Authors:  Eike Rietzel; Arthur K Liu; Karen P Doppke; John A Wolfgang; Aileen B Chen; George T Y Chen; Noah C Choi
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-09-01       Impact factor: 7.038

7.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76.

Authors:  Paul J Keall; Gig S Mageras; James M Balter; Richard S Emery; Kenneth M Forster; Steve B Jiang; Jeffrey M Kapatoes; Daniel A Low; Martin J Murphy; Brad R Murray; Chester R Ramsey; Marcel B Van Herk; S Sastry Vedam; John W Wong; Ellen Yorke
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

8.  Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates.

Authors:  Ross I Berbeco; Seiko Nishioka; Hiroki Shirato; George T Y Chen; Steve B Jiang
Journal:  Phys Med Biol       Date:  2005-07-28       Impact factor: 3.609

9.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

Authors:  Yvette Seppenwoolde; Hiroki Shirato; Kei Kitamura; Shinichi Shimizu; Marcel van Herk; Joos V Lebesque; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-07-15       Impact factor: 7.038

10.  Reproducibility of target volumes generated using uncoached 4-dimensional CT scans for peripheral lung cancer.

Authors:  Ylanga G van der Geld; Frank J Lagerwaard; John R van Sörnsen de Koste; Johan P Cuijpers; Ben J Slotman; Suresh Senan
Journal:  Radiat Oncol       Date:  2006-11-01       Impact factor: 3.481

View more
  2 in total

1.  Ventilatory impairment detection based on distribution of respiratory-induced changes in pixel values in dynamic chest radiography: a feasibility study.

Authors:  Rie Tanaka; Shigeru Sanada; Masaki Fujimura; Masahide Yasui; Shiro Tsuji; Norio Hayashi; Hiroyuki Okamoto; Yuko Nanbu; Osamu Matsui
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-06-13       Impact factor: 2.924

2.  Efficiency and reporting confidence analysis of sequential dual-energy subtraction for thoracic x-ray examinations.

Authors:  Mehmet Can Gezer; Oktay Algin; Aytac Durmaz; Halil Arslan
Journal:  Qatar Med J       Date:  2019-09-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.