Comparison of blood counts in venous, fingertip and arterial blood and their measurement variation.

Z W Yang1, S H Yang, L Chen, J Qu, J Zhu, Z Tang.   

Abstract

We compared routine blood pictures in venous, fingertip and arterial blood and their measurement variation. A pair of venous and fingertip blood samples were simultaneously collected from 24 volunteers, and another pair of venous and arterial samples from another 12 volunteers. The volunteers were healthy adults, aged 20-22 years, with males and females in equal numbers. Three aliquots of blood were taken from each person for three measurements of blood counts, including haemoglobin concentration and haematocrit, using an automatic haematology analyser. Compared to arterial blood, there was a significant increase of erythrocyte count (2.7%) and haematocrit (3.1%) in the venous blood. The total and large leucocyte counts were significantly higher (9.2% and 12.6%, respectively) in the fingertip blood than in the venous blood. There were a decreasing number of leucocytes in the fingertip blood with repeated sampling. The intermeasurement variation for total leucocyte or haemoglobin measurement was significantly larger as measured with the fingertip blood or arterial blood than with the venous blood. The intermeasurement coefficients of variation of haemoglobin (1.3%) and small leucocyte ratio or platelet (approximately 4.0%) measurements with venous and arterial blood were the smallest and largest, respectively. Volume of arterial plasma was diminished by 2-3% after microcirculation. Elevation of total leucocyte count in the fingertip blood was mainly due to the increase of granulocytes. Measurement with venous blood was of better precision than with fingertip or arterial blood.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11553055     DOI: 10.1046/j.1365-2257.2001.00388.x

Source DB:  PubMed          Journal:  Clin Lab Haematol        ISSN: 0141-9854


  46 in total

1.  Phaseguide-assisted blood separation microfluidic device for point-of-care applications.

Authors:  Linfeng Xu; Hun Lee; Mariana Vanderlei Brasil Pinheiro; Phil Schneider; Deekshitha Jetta; Kwang W Oh
Journal:  Biomicrofluidics       Date:  2015-01-21       Impact factor: 2.800

Review 2.  Factors affecting hemoglobin measurement.

Authors:  Lauren Berkow
Journal:  J Clin Monit Comput       Date:  2013-03-26       Impact factor: 2.502

3.  Biospecimen reporting for improved study quality (BRISQ).

Authors:  Helen M Moore; Andrea B Kelly; Scott D Jewell; Lisa M McShane; Douglas P Clark; Renata Greenspan; Daniel F Hayes; Pierre Hainaut; Paula Kim; Elizabeth Mansfield; Olga Potapova; Peter Riegman; Yaffa Rubinstein; Edward Seijo; Stella Somiari; Peter Watson; Heinz-Ulrich Weier; Claire Zhu; Jim Vaught
Journal:  J Proteome Res       Date:  2011-06-21       Impact factor: 4.466

4.  Fingerprick autologous blood: a novel treatment for dry eye syndrome.

Authors:  J Than; S Balal; J Wawrzynski; N Nesaratnam; G M Saleh; J Moore; A Patel; S Shah; B Sharma; B Kumar; J Smith; A Sharma
Journal:  Eye (Lond)       Date:  2017-06-16       Impact factor: 3.775

Review 5.  Methods and analyzers for hemoglobin measurement in clinical laboratories and field settings.

Authors:  Ralph D Whitehead; Zuguo Mei; Carine Mapango; Maria Elena D Jefferds
Journal:  Ann N Y Acad Sci       Date:  2019-06-04       Impact factor: 5.691

6.  Biospecimen Reporting for Improved Study Quality.

Authors:  Helen M Moore; Andrea Kelly; Scott D Jewell; Lisa M McShane; Douglas P Clark; Renata Greenspan; Pierre Hainaut; Daniel F Hayes; Paula Kim; Elizabeth Mansfield; Olga Potapova; Peter Riegman; Yaffa Rubinstein; Edward Seijo; Stella Somiari; Peter Watson; Heinz-Ulrich Weier; Claire Zhu; Jim Vaught
Journal:  Biopreserv Biobank       Date:  2011-04       Impact factor: 2.300

7.  Comparison of capillary and venous blood in the analysis of concentration and function of leucocyte sub-populations.

Authors:  Elisa F D Canetti; J Keane; C P McLellan; A B Gray
Journal:  Eur J Appl Physiol       Date:  2016-06-15       Impact factor: 3.078

8.  Performance evaluation of the MBio Diagnostics point-of-care CD4 counter.

Authors:  Cathy Logan; Monique Givens; Jeffrey T Ives; Marie Delaney; Michael J Lochhead; Robert T Schooley; Constance A Benson
Journal:  J Immunol Methods       Date:  2012-10-11       Impact factor: 2.303

9.  A comparison of ex vivo cytokine production in venous and capillary blood.

Authors:  M Eriksson; E Sartono; C L Martins; C Balé; M-L Garly; H Whittle; P Aaby; B K Pedersen; M Yazdanbakhsh; C Erikstrup; C S Benn
Journal:  Clin Exp Immunol       Date:  2007-10-09       Impact factor: 4.330

10.  Point-of-care method for total white cell count: an evaluation of the HemoCue WBC device.

Authors:  A Osei-Bimpong; C Jury; R McLean; S M Lewis
Journal:  Int J Lab Hematol       Date:  2008-08-28       Impact factor: 2.877

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.