Literature DB >> 23063690

Performance evaluation of the MBio Diagnostics point-of-care CD4 counter.

Cathy Logan1, Monique Givens, Jeffrey T Ives, Marie Delaney, Michael J Lochhead, Robert T Schooley, Constance A Benson.   

Abstract

The measurement of the absolute CD4 T-cell count is critical in the initial evaluation and staging of HIV-infected persons, yet access to this technology remains limited in many low resource settings where disease burden is highest. Here we evaluate the performance of a prototype point-of-care device (POC) to quantify CD4 T cells from MBio Diagnostics, Inc. Whole blood samples, both venous and capillary (finger stick), were collected from known HIV-infected participants at the University of California, San Diego Antiviral Research Center, and tested using the MBio system and conventional flow cytometry. A total of 94 venipuncture and 52 capillary samples were processed and statistical analyses included comparison to flow cytometry results. For the venipuncture samples, Bland-Altman analysis resulted in a mean bias of -10 cells/μL (-23 to +3 cells/μL, 95% CI), and limits of agreement (LOA) of -132 and +112 cells/μL. For the capillary samples, Bland-Altman resulted in a mean bias of -4 cells/μL (-31 to +23 cells/μL, 95% CL), and LOA of -195 and +186 cells/μL. For the San Diego study cohort, the prototype MBio system showed negligible quantitative bias relative to flow cytometry. Higher variability was observed in the capillary samples relative to venipuncture, but system precision for both capillary and venipuncture samples was good. There was also close agreement between results from the same participant when tested with two different systems, different operators and different locations. This preliminary evaluation suggests that the MBio CD4 device holds promise as a POC system for quantitation of CD4 T cells in limited-resource settings.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23063690      PMCID: PMC3529779          DOI: 10.1016/j.jim.2012.10.002

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  37 in total

1.  Multiple method comparison: statistical model using percentage similarity.

Authors:  Lesley E Scott; Jacky S Galpin; Deborah K Glencross
Journal:  Cytometry B Clin Cytom       Date:  2003-07       Impact factor: 3.058

2.  A reliable and inexpensive EasyCD4 assay for monitoring HIV-infected individuals in resource-limited settings.

Authors:  Pachamuthu Balakrishnan; Suniti Solomon; Janardhanan Mohanakrishnan; Anitha J Cecelia; Nagalingeswaran Kumarasamy; Kailapuri G Murugavel; Bhavani Venkatakrishnan; Sunil S Solomon; Suzanne M Crowe; Aylur K Ganesh; Sadras P Thyagarajan; Timothy Flanigan; Kenneth H Mayer
Journal:  J Acquir Immune Defic Syndr       Date:  2006-09       Impact factor: 3.731

3.  Accurate CD4 T-cell enumeration and antiretroviral drug toxicity monitoring in primary healthcare clinics using point-of-care testing.

Authors:  Ilesh V Jani; Nádia E Sitoe; Patrina L Chongo; Eunice R Alfai; Jorge I Quevedo; Ocean Tobaiwa; Jonathan D Lehe; Trevor F Peter
Journal:  AIDS       Date:  2011-03-27       Impact factor: 4.177

Review 4.  Emerging technologies for point-of-care CD4 T-lymphocyte counting.

Authors:  David S Boyle; Kenneth R Hawkins; Matthew S Steele; Mitra Singhal; Xuanhong Cheng
Journal:  Trends Biotechnol       Date:  2011-07-26       Impact factor: 19.536

5.  Comparison of Dynabeads and Capcellia methods with FACScount for the estimation of CD4 T-lymphocyte levels in HIV/AIDS patients in Lagos, Nigeria.

Authors:  E O Idigbe; R A Audu; C T Oparaugo; D Onwujekwe; C C Onubogu; J Adedoyin; A G Mafe; R Okoye; J I Onyewuche; E O Funso-Adebayo; E Meshack
Journal:  East Afr Med J       Date:  2006-04

6.  The "ART" of linkage: pre-treatment loss to care after HIV diagnosis at two PEPFAR sites in Durban, South Africa.

Authors:  Elena Losina; Ingrid V Bassett; Janet Giddy; Senica Chetty; Susan Regan; Rochelle P Walensky; Douglas Ross; Callie A Scott; Lauren M Uhler; Jeffrey N Katz; Helga Holst; Kenneth A Freedberg
Journal:  PLoS One       Date:  2010-03-04       Impact factor: 3.240

Review 7.  Strategies to optimize HIV treatment outcomes in resource-limited settings.

Authors:  Damalie Nakanjako; Robert Colebunders; Alex G Coutinho; Moses R Kamya
Journal:  AIDS Rev       Date:  2009 Oct-Dec       Impact factor: 2.500

8.  Loss to care and death before antiretroviral therapy in Durban, South Africa.

Authors:  Ingrid V Bassett; Bingxia Wang; Senica Chetty; Matilda Mazibuko; Benjamin Bearnot; Janet Giddy; Zhigang Lu; Elena Losina; Rochelle P Walensky; Kenneth A Freedberg
Journal:  J Acquir Immune Defic Syndr       Date:  2009-06-01       Impact factor: 3.731

9.  A rapid manual method for CD4+ T-cell quantitation for use in developing countries.

Authors:  A Landay; J L Ho; D Hom; T Russell; R Zwerner; J G Minuty; P Kataaha; F Mmiro; B Jackson
Journal:  AIDS       Date:  1993-12       Impact factor: 4.177

10.  Comparison of capillary based microflurometric assay for CD4+ T cell count estimation with dual platform Flow cytometry.

Authors:  Madhuri R Thakar; B Kishore Kumar; Bharati A Mahajan; Sanjay M Mehendale; Ramesh S Paranjape
Journal:  AIDS Res Ther       Date:  2006-10-16       Impact factor: 2.250

View more
  11 in total

1.  A flow-through cell counting assay for point-of-care enumeration of CD4 T-cells.

Authors:  Simon Bystryak; Rajiv P Bandwar; Rasa Santockyte
Journal:  J Virol Methods       Date:  2019-05-28       Impact factor: 2.014

Review 2.  Developments in CD4 and viral load monitoring in resource-limited settings.

Authors:  Christopher F Rowley
Journal:  Clin Infect Dis       Date:  2013-11-11       Impact factor: 9.079

3.  Near patient CD4 count in a hospitalized HIV patient population.

Authors:  Monique Givens; Amanda Weaver; Sarah Bickman; Cathy Logan; Emilia V Noormahomed; Sam Patel; Robert T Schooley; Constance A Benson; Michael J Lochhead
Journal:  Cytometry B Clin Cytom       Date:  2015-05-27       Impact factor: 3.058

Review 4.  Evanescent wave fluorescence biosensors: Advances of the last decade.

Authors:  Chris Rowe Taitt; George P Anderson; Frances S Ligler
Journal:  Biosens Bioelectron       Date:  2015-07-20       Impact factor: 10.618

5.  Laboratory and field evaluation of the Partec CyFlow miniPOC for absolute and relative CD4 T-cell enumeration.

Authors:  Djibril Wade; Papa Alassane Diaw; Géraldine Daneau; Abdoul Aziz Diallo; Souleymane Mboup; Tandakha Ndiaye Dieye; Luc Kestens
Journal:  PLoS One       Date:  2015-02-17       Impact factor: 3.240

6.  WHO multicenter evaluation of FACSCount CD4 and Pima CD4 T-cell count systems: instrument performance and misclassification of HIV-infected patients.

Authors:  Djibril Wade; Géraldine Daneau; Said Aboud; Gaby H Vercauteren; Willy S K Urassa; Luc Kestens
Journal:  J Acquir Immune Defic Syndr       Date:  2014-08-15       Impact factor: 3.731

Review 7.  CD4 enumeration technologies: a systematic review of test performance for determining eligibility for antiretroviral therapy.

Authors:  Rosanna W Peeling; Kimberly A Sollis; Sarah Glover; Suzanne M Crowe; Alan L Landay; Ben Cheng; David Barnett; Thomas N Denny; Thomas J Spira; Wendy S Stevens; Siobhan Crowley; Shaffiq Essajee; Marco Vitoria; Nathan Ford
Journal:  PLoS One       Date:  2015-03-19       Impact factor: 3.240

8.  Performance verification of the new fully automated Aquios flow cytometer PanLeucogate (PLG) platform for CD4-T-lymphocyte enumeration in South Africa.

Authors:  Lindi-Marie Coetzee; Deborah K Glencross
Journal:  PLoS One       Date:  2017-11-03       Impact factor: 3.240

9.  Performance Evaluation of the Becton Dickinson FACSPresto™ Near-Patient CD4 Instrument in a Laboratory and Typical Field Clinic Setting in South Africa.

Authors:  Lindi-Marie Coetzee; Keshendree Moodley; Deborah Kim Glencross
Journal:  PLoS One       Date:  2016-05-25       Impact factor: 3.240

10.  Feasibility of HIV point-of-care tests for resource-limited settings: challenges and solutions.

Authors:  Wendy Stevens; Natasha Gous; Nathan Ford; Lesley E Scott
Journal:  BMC Med       Date:  2014-09-08       Impact factor: 8.775

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.