Literature DB >> 11521922

All-polyethylene versus metal-backed and stemmed tibial components in cemented total knee arthroplasty. A prospective, randomised RSA study.

G Adalberth1, K G Nilsson, S Byström, K Kolstad, J Milbrink.   

Abstract

We studied the quality of fixation of the tibial component using radiostereometric analysis (RSA) in 40 patients who had undergone a cemented Freeman-Samuelson total knee arthroplasty. They were prospectively randomised to either a stemmed metal-backed (MB) or non-stemmed all-polyethylene (AP) tibial component. The articulating geometry of the implants was identical, as was the operative technique and the postoperative regime. The study showed no complications of fixation using AP tibial components, and the migration was the same as that of their metal-backed counterparts. There was no bony collapse or increased subsidence of any part of the tibial component or increased incidence of radiolucent lines in the knees with AP components. Most AP implants were stable between one and two years after surgery, a finding known to be of positive prognostic significance when predicting future aseptic loosening.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11521922     DOI: 10.1302/0301-620x.83b6.11430

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  14 in total

Review 1.  Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?

Authors:  Tao Cheng; Xiaoyun Pan; Tao Liu; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-05       Impact factor: 4.342

2.  Finite element analysis: a comparison of an all-polyethylene tibial implant and its metal-backed equivalent.

Authors:  S M Thompson; D Yohuno; W N Bradley; A D Crocombe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-22       Impact factor: 4.342

3.  Primary stability of tibial components in TKA: in vitro comparison of two cementing techniques.

Authors:  Adrian Skwara; J Figiel; T Knott; J R J Paletta; S Fuchs-Winkelmann; C O Tibesku
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-02       Impact factor: 4.342

Review 4.  All-polyethylene tibial components are equal to metal-backed components: systematic review and meta-regression.

Authors:  Klaas Auke Nouta; Wiebe C Verra; Bart G Pijls; Jan W Schoones; Rob G H H Nelissen
Journal:  Clin Orthop Relat Res       Date:  2012-09-13       Impact factor: 4.176

Review 5.  All-polyethylene versus metal-backed tibial component in total knee arthroplasty.

Authors:  Umile Giuseppe Longo; Mauro Ciuffreda; Valerio D'Andrea; Nicholas Mannering; Joel Locher; Vincenzo Denaro
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-21       Impact factor: 4.342

Review 6.  Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties.

Authors:  Bart G Pijls; Edward R Valstar; Klaas-Auke Nouta; Josepha Wm Plevier; Marta Fiocco; Saskia Middeldorp; Rob Ghh Nelissen
Journal:  Acta Orthop       Date:  2012-11-09       Impact factor: 3.717

7.  All-polyethylene tibial components in TKA in rheumatoid arthritis: a 25-year follow-up study.

Authors:  Klaas-Auke Nouta; Bart G Pijls; Rob G H H Nelissen
Journal:  Int Orthop       Date:  2011-09-01       Impact factor: 3.075

8.  Metal-backed versus all-polyethylene tibial components in primary total knee arthroplasty.

Authors:  Tao Cheng; Guoyou Zhang; Xianlong Zhang
Journal:  Acta Orthop       Date:  2011-09-06       Impact factor: 3.717

Review 9.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

10.  Tibial component rotation around the transverse axis measured by radiostereometry predicts aseptic loosening better than maximal total point motion.

Authors:  Asgeir Gudnason; Gunnar Adalberth; Kjell-Gunnar Nilsson; Nils P Hailer
Journal:  Acta Orthop       Date:  2017-03-07       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.