Literature DB >> 11520634

Chronic electrical stimulation of the auditory nerve using high surface area (HiQ) platinum electrodes.

M Tykocinski1, Y Duan, B Tabor, R S Cowan.   

Abstract

High surface area cochlear implant electrodes with much smaller geometric surface areas than current designs might be used in the future to increase the number of stimulating electrodes along the carrier. Potential problems with an increase in charge density for a common stimulus resulting from decreasing the geometric surface area would be reduced by the enlarged real surface area of such electrodes. Electrochemically modified (HiQ) platinum (Pt) electrodes, with a real surface area approximately 75 times greater than the current standard Pt electrodes of the same geometric size, had shown in vitro a low polarization (Z(pol)) and electrode impedance (Z(e)), as well as a low residual direct current (DC). In this study we examined the chronic performance of HiQ electrodes in cats, which were bilaterally implanted with a two-channel HiQ or standard Pt scala tympani electrode array and unilaterally stimulated for periods of up to 2390 h. Stimuli consisted of 50 micros/phase charge-balanced biphasic current pulses presented at 2000 pulses/s/channel with a 50% duty cycle. Electrode impedance (Z(e)), access resistance (R(a)) and polarization impedance (Z(pol)) were calculated from current and voltage measurements obtained periodically throughout the implantation period. Immediately following implantation HiQ electrodes showed a significantly smaller Z(pol), resulting in a reduced Z(e) (P<0.0001) compared to standard electrodes, while there was no significant difference between R(a) of both electrode designs (P=0.91). Subsequently, Z(e) generally increased mainly due to a rise in R(a), which dominated Z(e) and obliterated the effect of a lower Z(pol) on Z(e) in HiQ electrodes. Peak R(a) levels correlated closely (r=0.85) with the amount of intracochlear fibrous tissue found adjacent to the array. Following explantation of the array, voltage waveforms for both electrode designs recorded in saline were again very similar to those recorded immediately after implantation. Mean DC levels were consistently lower for HiQ electrodes compared with standard electrodes (22.45 nA vs 134.7 nA). Histopathological examination of corresponding cochlear sections comparing the stimulated test side with the unstimulated control side showed no significant difference (P>0.05) for either animals implanted with HiQ electrodes (n=6) or standard electrodes (n=2). Nor were there any significant differences between the spiral ganglion cell density of the basal turn implanted with HiQ or standard electrodes for both the stimulated test (P=0.31) and the unstimulated control side (P=0.84). Although these findings are based on a small group of animals implanted with standard electrodes (n=2), and those negative statistical results could potentially be due to the small sample size, similar spiral ganglion cell survival was found in a previous study of a larger group of animals using standard electrodes stimulated with the same stimulus paradigm as in the present study [Xu et al. (1997) Hear. Res. 105, 1-29]. Our data indicate that while some initial advantages of HiQ electrodes are lost during chronic implantation due to intracochlear fibrous tissue growth, low DC levels and the high surface area appear to be maintained, suggesting that HiQ electrodes may have important clinical applications.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11520634     DOI: 10.1016/s0378-5955(01)00320-3

Source DB:  PubMed          Journal:  Hear Res        ISSN: 0378-5955            Impact factor:   3.208


  15 in total

1.  How electrically evoked compound action potentials in chronically implanted guinea pigs relate to auditory nerve health and electrode impedance.

Authors:  Kara C Schvartz-Leyzac; Deborah J Colesa; Christopher J Buswinka; Andrew M Rabah; Donald L Swiderski; Yehoash Raphael; Bryan E Pfingst
Journal:  J Acoust Soc Am       Date:  2020-12       Impact factor: 1.840

2.  Electron transfer processes occurring on platinum neural stimulating electrodes: calculated charge-storage capacities are inaccessible during applied stimulation.

Authors:  Eric M Hudak; Doe W Kumsa; Heidi B Martin; J Thomas Mortimer
Journal:  J Neural Eng       Date:  2017-08       Impact factor: 5.379

3.  Changes over time in the electrically evoked compound action potential (ECAP) interphase gap (IPG) effect following cochlear implantation in Guinea pigs.

Authors:  Kara C Schvartz-Leyzac; Deborah J Colesa; Christopher J Buswinka; Donald L Swiderski; Yehoash Raphael; Bryan E Pfingst
Journal:  Hear Res       Date:  2019-10-04       Impact factor: 3.208

4.  Changes in biphasic electrode impedance with protein adsorption and cell growth.

Authors:  Carrie Newbold; Rachael Richardson; Rodney Millard; Christie Huang; Dusan Milojevic; Robert Shepherd; Robert Cowan
Journal:  J Neural Eng       Date:  2010-09-14       Impact factor: 5.379

5.  Access and Polarization Electrode Impedance Changes in Electric-Acoustic Stimulation Cochlear Implant Users with Delayed Loss of Acoustic Hearing.

Authors:  Viral D Tejani; Hyejin Yang; Jeong-Seo Kim; Helin Hernandez; Jacob J Oleson; Marlan R Hansen; Bruce J Gantz; Paul J Abbas; Carolyn J Brown
Journal:  J Assoc Res Otolaryngol       Date:  2021-10-22

6.  The development of neural stimulators: a review of preclinical safety and efficacy studies.

Authors:  Robert K Shepherd; Joel Villalobos; Owen Burns; David A X Nayagam
Journal:  J Neural Eng       Date:  2018-05-14       Impact factor: 5.379

7.  Across-site patterns of electrically evoked compound action potential amplitude-growth functions in multichannel cochlear implant recipients and the effects of the interphase gap.

Authors:  Kara C Schvartz-Leyzac; Bryan E Pfingst
Journal:  Hear Res       Date:  2016-08-10       Impact factor: 3.208

Review 8.  Tissue damage thresholds during therapeutic electrical stimulation.

Authors:  Stuart F Cogan; Kip A Ludwig; Cristin G Welle; Pavel Takmakov
Journal:  J Neural Eng       Date:  2016-01-20       Impact factor: 5.379

9.  Direct current contamination of kilohertz frequency alternating current waveforms.

Authors:  Manfred Franke; Niloy Bhadra; Narendra Bhadra; Kevin Kilgore
Journal:  J Neurosci Methods       Date:  2014-05-10       Impact factor: 2.390

10.  Input-Output Functions in Human Heads Obtained With Cochlear Implant and Transcranial Electric Stimulation.

Authors:  Phillip Tran; Matthew L Richardson; Fan-Gang Zeng
Journal:  Neuromodulation       Date:  2019-11-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.