Literature DB >> 1151485

Effect of positron range on spatial resolution.

M E Phelps, E J Hoffman, S C Huang, M M Ter-Pogossian.   

Abstract

The effect of beta+ range on spatial resolution of imaging systems employing the detection of 511-keV annihilation radiation was determined by measuring the variation in the line-spread functions (LSFs) of positron-emitting radionuclides of 64Cu, 11C, and 15O as compared with the 514-keV gamma-ray emitter 85Sr. These radionuclides have maximum beta+ energies of 0.656, 0.960, and 1.72 MeV, respectively. The LSFs were measured in a tissue-equivalent phantom with high-resolution (approximately 2.4 mm FWHM) and low-resolution (approximately 8.8 mm FWHM) straightbore collimators coupled to a NaI(Tl) detector. Theoretical LSFs for the beta+ ranges were also calculated and convolved with the 85Sr LSF to yield the predicted LSFs for 11C and 15O. The high-resolution study showed a 0% and 2.3% increase in the full-width half-maximum (FWHM) and full-width tenth-maximum (FWO.1M) for the low-energy beta+ of 64Cu and a 37% (FWHM) and 52% (FWO.1M) increase for the high energy beta+ of 15O as compared with 85Sr. However, when the system resolution was decreased to 8.8 mm FWHM, the 64Cu showed no change at FWHM or FWO.1M and the 15O showed a 2.3% (FWHM) and 7.8% (FWO.1M) relative to 85Sr. The predicted LSFs were in good agreement with the experimental. These data indicate that the effect of beta+ range on spatial resolution is minimal unless the beta+ energy is larger than or equal to 1.5 MeV and the system resolution is on the order of a few millimeters.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1151485

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  18 in total

1.  Positron emission tomography.

Authors:  A A Lammertsma
Journal:  Brain Topogr       Date:  1992       Impact factor: 3.020

Review 2.  Small animal PET: aspects of performance assessment.

Authors:  Simone Weber; Andreas Bauer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-10-02       Impact factor: 9.236

3.  A residual correction method for high-resolution PET reconstruction with application to on-the-fly Monte Carlo based model of positron range.

Authors:  Lin Fu; Jinyi Qi
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

Review 4.  Cardiac PET for translational imaging.

Authors:  C Rischpler; Anna Paschali; Constantinos Anagnostopoulos; S G Nekolla
Journal:  Curr Cardiol Rep       Date:  2015-05       Impact factor: 2.931

Review 5.  Is there still a role for SPECT-CT in oncology in the PET-CT era?

Authors:  Rodney J Hicks; Michael S Hofman
Journal:  Nat Rev Clin Oncol       Date:  2012-11-13       Impact factor: 66.675

6.  Spatially Variant Positron Range Modeling Derived from CT for PET Image Reconstruction.

Authors:  Adam Alessio; Lawrence MacDonald
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2008

7.  Longitudinal PET-MRI reveals β-amyloid deposition and rCBF dynamics and connects vascular amyloidosis to quantitative loss of perfusion.

Authors:  Florian C Maier; Hans F Wehrl; Andreas M Schmid; Julia G Mannheim; Stefan Wiehr; Chommanad Lerdkrai; Carsten Calaminus; Anke Stahlschmidt; Lan Ye; Michael Burnet; Detlef Stiller; Osama Sabri; Gerald Reischl; Mathias Staufenbiel; Olga Garaschuk; Mathias Jucker; Bernd J Pichler
Journal:  Nat Med       Date:  2014-11-10       Impact factor: 53.440

8.  Improved spatial resolution in PET scanners using sampling techniques.

Authors:  Suleman Surti; Ryan Scheuermann; Matthew E Werner; Joel S Karp
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-01       Impact factor: 1.679

Review 9.  Positron emission tomography imaging of prostate cancer.

Authors:  Hao Hong; Yin Zhang; Jiangtao Sun; Weibo Cai
Journal:  Amino Acids       Date:  2009-11-28       Impact factor: 3.520

Review 10.  New radiotracers for imaging of vascular targets in angiogenesis-related diseases.

Authors:  Hao Hong; Feng Chen; Yin Zhang; Weibo Cai
Journal:  Adv Drug Deliv Rev       Date:  2014-07-30       Impact factor: 15.470

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.