Literature DB >> 11513948

Stimulus artifact removal using a software-based two-stage peak detection algorithm.

D T O'Keeffe1, G M Lyons, A E Donnelly, C A Byrne.   

Abstract

The analysis of stimulus evoked neuromuscular potentials or m-waves is a useful technique for improved feedback control in functional electrical stimulation systems. Usually, however, these signals are contaminated by stimulus artifact. A novel software technique, which uses a two-stage peak detection algorithm, has been developed to remove the unwanted artifact from the recorded signal. The advantage of the technique is that it can be used on all stimulation artifact-contaminated electroneurophysiologic data provided that the artifact and the biopotential are non-overlapping. The technique does not require any estimation of the stimulus artifact shape or duration. With the developed technique, it is not necessary to record a pure artifact signal for template estimation, a process that can increase the complexity of experimentation. The technique also does not require the recording of any external hardware synchronisation pulses. The method avoids the use of analogue or digital filtering techniques, which endeavour to remove certain high frequency components of the artifact signal, but invariably have difficulty, resulting in the removal of frequencies in the same spectrum as the m-wave. With the new technique the signal is sampled at a high frequency to ensure optimum fidelity. Instrumentation saturation effects due to the artifact can be avoided with careful electrode placement. The technique was fully tested with a wide variety of electrical stimulation parameters (frequency and pulse width) applied to the common peroneal nerve to elicit contraction in the tibialis anterior. The program was also developed to allow batch processing of multiple files, using closed loop feedback correction. The two-stage peak detection artifact removal algorithm is demonstrated as an efficient post-processing technique for acquiring artifact free m-waves.

Mesh:

Year:  2001        PMID: 11513948     DOI: 10.1016/s0165-0270(01)00407-1

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  15 in total

1.  A novel stimulus artifact removal technique for high-rate electrical stimulation.

Authors:  Leon F Heffer; James B Fallon
Journal:  J Neurosci Methods       Date:  2008-02-03       Impact factor: 2.390

2.  Effects of fatigue on the electromechanical delay components in gastrocnemius medialis muscle.

Authors:  Susanna Rampichini; Emiliano Cè; Eloisa Limonta; Fabio Esposito
Journal:  Eur J Appl Physiol       Date:  2013-12-21       Impact factor: 3.078

3.  A novel device to suppress electrical stimulus artifacts in electrophysiological experiments.

Authors:  Thomas Wichmann; Annaelle Devergnas
Journal:  J Neurosci Methods       Date:  2011-07-01       Impact factor: 2.390

4.  Electrophysiology equipment for reliable study of kHz electrical stimulation.

Authors:  Mohamad FallahRad; Adantchede Louis Zannou; Niranjan Khadka; Steven A Prescott; Stéphanie Ratté; Tianhe Zhang; Rosana Esteller; Brad Hershey; Marom Bikson
Journal:  J Physiol       Date:  2019-03-18       Impact factor: 5.182

5.  Suppression of stimulus artifact contaminating electrically evoked electromyography.

Authors:  Jie Liu; Sheng Li; Xiaoyan Li; Cliff Klein; William Z Rymer; Ping Zhou
Journal:  NeuroRehabilitation       Date:  2014       Impact factor: 2.138

6.  Changes in the electromechanical delay components during a fatiguing stimulation in human skeletal muscle: an EMG, MMG and force combined approach.

Authors:  Emiliano Cè; Susanna Rampichini; Elena Monti; Massimo Venturelli; Eloisa Limonta; Fabio Esposito
Journal:  Eur J Appl Physiol       Date:  2016-11-17       Impact factor: 3.078

7.  Complete optical neurophysiology: toward optical stimulation and recording of neural tissue.

Authors:  Fred A Wininger; Jennifer L Schei; David M Rector
Journal:  Appl Opt       Date:  2009-04-01       Impact factor: 1.980

8.  Signal processing methods for reducing artifacts in microelectrode brain recordings caused by functional electrical stimulation.

Authors:  D Young; F Willett; W D Memberg; B Murphy; B Walter; J Sweet; J Miller; L R Hochberg; R F Kirsch; A B Ajiboye
Journal:  J Neural Eng       Date:  2018-04       Impact factor: 5.379

9.  ERAASR: an algorithm for removing electrical stimulation artifacts from multielectrode array recordings.

Authors:  Daniel J O'Shea; Krishna V Shenoy
Journal:  J Neural Eng       Date:  2018-04       Impact factor: 5.379

10.  High-frequency electrical stimulation in the nucleus accumbens of morphine-treated rats suppresses neuronal firing in reward-related brain regions.

Authors:  Wen-han Hu; Yong-feng Bi; Kai Zhang; Fan-gang Meng; Jian-guo Zhang
Journal:  Med Sci Monit       Date:  2011-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.