Literature DB >> 11476320

Evaluation of accuracy and precision of bone markers for the measurement of migration of hip prostheses. A comparison of conventional measurements.

R Biedermann1, B Stöckl, M Krismer, P Mayrhofer, E Ornstein, H Franzén.   

Abstract

Our aim was to determine whether tantalum m arkers improved the accuracy and/or precision of methods for the measurement of migration in total hip replacement based on conventional measurements without mathematical correction of the data, and with Ein Bild Roentgen Analyse - Femoral Component Analysis (EBRA-FCA) which allows a computerised correction. Three observers independently analysed 13 series of roentgen-stereophotogrammetric-analysis (RSA)-compatible radiographs (88). Data were obtained from conventional measurements, EBRA-FCA and the RSA method and all the results were compared with the RSA data. Radiological evaluation was also used to quantify in how many radiographs the intraosseous position of the bone markers had been simulated. The results showed that tantalum markers improve reliability whereas they do not affect accuracy for conventional measurements and for EBRA-FCA. Because of the danger of third-body wear their implantation should be avoided unless they are an integral part of the method.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11476320     DOI: 10.1302/0301-620x.83b5.10575

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  10 in total

1.  Is Plain Anterior-Posterior Radiograph of the Pelvis Adequate for Assessment of Radiographic Implant Migration Evaluation in Total Hip Arthroplasty?

Authors:  Alexander Cm Chong; Lisa N MacFadden; Bruce E Piatt; Benjamin C Noonan
Journal:  Iowa Orthop J       Date:  2020

2.  Reduced femoral component subsidence with improved impaction grafting at revision hip arthroplasty.

Authors:  D W Howie; S A Callary; M A McGee; N C Russell; L B Solomon
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

3.  High incidence of migration with poor initial fixation of the Accolade stem.

Authors:  Craig A White; Sasha Carsen; Kevin Rasuli; Robert J Feibel; Paul R Kim; Paul E Beaulé
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

4.  Early Migration Predicts Aseptic Loosening of Cementless Femoral Stems: A Long-term Study.

Authors:  Marcus R Streit; Daniel Haeussler; Thomas Bruckner; Tanja Proctor; Moritz M Innmann; Christian Merle; Tobias Gotterbarm; Stefan Weiss
Journal:  Clin Orthop Relat Res       Date:  2016-04-29       Impact factor: 4.176

5.  The migration of femoral components after total hip replacement surgery: accuracy and precision of software-aided measurements.

Authors:  J Decking; U Schuetz; R Decking; W Puhl
Journal:  Skeletal Radiol       Date:  2003-07-31       Impact factor: 2.199

6.  [Accuracy of hip stem migration measurement on plain radiographs: reliability of bony and prosthetic landmarks].

Authors:  R Bieger; B Cakir; H Reichel; T Kappe
Journal:  Orthopade       Date:  2014-10       Impact factor: 1.087

7.  Poor accuracy of plain radiographic measurements of prosthetic migration and alignment in total ankle replacement.

Authors:  Matthias Braito; Michael Liebensteiner; Dietmar Dammerer; Martin Krismer; Martin Pfurner; Rainer Biedermann
Journal:  J Orthop Surg Res       Date:  2015-05-20       Impact factor: 2.359

8.  Cementless Stem for Femoral Neck Fractures in a Patient's 10th Decade of Life: High Rate of Periprosthetic Fractures.

Authors:  Method Kabelitz; Yannick Fritz; Patrick Grueninger; Christoph Meier; Patrick Fries; Michael Dietrich
Journal:  Geriatr Orthop Surg Rehabil       Date:  2018-03-29

9.  Mid-term subsidence and periprosthetic radiolucency of the AMIStem: a 5-year EBRA-FCA analysis.

Authors:  Julian Hasler; Andreas Flury; Dimitris Dimitriou; Iris Holweg; Naeder Helmy; Michael Finsterwald
Journal:  J Orthop Surg Res       Date:  2021-01-07       Impact factor: 2.359

10.  Biomechanical Evaluation of the Accuracy in Radiographic Assessment of Femoral Component Migration Measurement after Total Hip Arthroplasty.

Authors:  Mikayla Forness; Zachary J Podoll; Benjamin C Noonan; Alexander C M Chong
Journal:  Kans J Med       Date:  2020-04-17