Literature DB >> 32742209

Is Plain Anterior-Posterior Radiograph of the Pelvis Adequate for Assessment of Radiographic Implant Migration Evaluation in Total Hip Arthroplasty?

Alexander Cm Chong1,2, Lisa N MacFadden1,3,4, Bruce E Piatt1,2,5, Benjamin C Noonan1,5.   

Abstract

Introduction: A commonly utilized method of measuring femoral stem migration in total hip arthroplasty (THA) on plain anteroposterior (AP) pelvis radiograph with referenced image magnification has not been rigorously evaluated. This study aims to validate the reproducibility of the methods used in this technique.
Methods: A retrospective study of the standardized AP pelvis radiographs of patients who had undergone THA utilizing a Corail® femoral stem was performed from June 2012 through December 2017. Radiological evaluation (head diameter, stem length, and stem seating length) were undertaken at three clinical follow-up times. Each radiographic measurement of each radiograph was repeated five times. Outcomes investigated included inter- and intra-radiograph reproducibility evaluation and radiographic image magnification. The stem length error and stem subsidence were also evaluated.
Results: Two hundred THA patients met the inclusion/ exclusion criteria. The intra-radiograph reproducibility of the stem length and head diameter measurements have at least "good" reproducibility with repeated measurements falling within 0.5 mm for both measurements. The reliability for femoral stem seating length measurements has "questionable/poor" reproducibility. The inter-radiograph reproducibility was, however, substantially lower. High level of unreliable measurements with values less than 0.0 mm for both femoral stem length errors (55%) and femoral stem subsidence (32%) measurements. Less than 45% accuracy (femoral stem length error: 33%; femoral stem subsidence: 44%) to within 3 mm error. Conclusions: This study demonstrates that the assessment of radiographic implant migration after THA made on a sequence of plain AP pelvis radiograph have poor reproducibility.Level of Evidence: III.
Copyright © The Iowa Orthopaedic Journal 2020.

Entities:  

Keywords:  displacement measurement; plain radiograph; radiological image magnification; reproducibility

Mesh:

Year:  2020        PMID: 32742209      PMCID: PMC7368518     

Source DB:  PubMed          Journal:  Iowa Orthop J        ISSN: 1541-5457


  32 in total

1.  Cementless Tapered Wedge Femoral Stems Decrease Subsidence in Obese Patients Compared to Traditional Fit-and-Fill Stems.

Authors:  Tanner W Grant; Luke R Lovro; David J Licini; Lucian C Warth; Mary Ziemba-Davis; Robert M Meneghini
Journal:  J Arthroplasty       Date:  2016-09-28       Impact factor: 4.757

2.  Early migration of uncemented porous coated anatomic femoral component related to aseptic loosening.

Authors:  Y H Kim; V E Kim
Journal:  Clin Orthop Relat Res       Date:  1993-10       Impact factor: 4.176

3.  A prospective short-term outcome study of a short metaphyseal fitting total hip arthroplasty.

Authors:  Young-Hoo Kim; Jun-Shik Kim; Jong-Hwan Joo; Jang-Won Park
Journal:  J Arthroplasty       Date:  2011-03-23       Impact factor: 4.757

4.  Does osteoporosis increase early subsidence of cementless double-tapered femoral stem in hip arthroplasty?

Authors:  Kee Hyung Rhyu; Se Min Lee; Young Soo Chun; Kang Il Kim; Yoon Je Cho; Myung Chul Yoo
Journal:  J Arthroplasty       Date:  2011-12-16       Impact factor: 4.757

5.  The effect of stem alignment on results of total hip arthroplasty with a cementless tapered-wedge femoral component.

Authors:  Byung-Woo Min; Kwang-Soon Song; Ki-Cheol Bae; Chul-Hyun Cho; Chul-Hyung Kang; Shin-Yoon Kim
Journal:  J Arthroplasty       Date:  2007-11-09       Impact factor: 4.757

6.  Migration of hydroxyapatite coated femoral prostheses. A Roentgen Stereophotogrammetric study.

Authors:  K Søballe; S Toksvig-Larsen; J Gelineck; S Fruensgaard; E S Hansen; L Ryd; U Lucht; C Bünger
Journal:  J Bone Joint Surg Br       Date:  1993-09

7.  In vivo measurements of relative motion between an uncemented femoral total hip component and the femur by roentgen stereophotogrammetric analysis.

Authors:  L Nistor; J D Blaha; U Kjellström; G Selvik
Journal:  Clin Orthop Relat Res       Date:  1991-08       Impact factor: 4.176

8.  Comparison of porous-coated titanium femoral stems with and without hydroxyapatite coating.

Authors:  Young-Hoo Kim; Jun-Shik Kim; Seung-Hwan Oh; Ju-Moon Kim
Journal:  J Bone Joint Surg Am       Date:  2003-09       Impact factor: 5.284

9.  Poor accuracy of plain radiographic measurements of prosthetic migration and alignment in total ankle replacement.

Authors:  Matthias Braito; Michael Liebensteiner; Dietmar Dammerer; Martin Krismer; Martin Pfurner; Rainer Biedermann
Journal:  J Orthop Surg Res       Date:  2015-05-20       Impact factor: 2.359

10.  Accuracy of radiographs in assessment of displacement in lateral humeral condyle fractures.

Authors:  Ashleen Knutsen; Tigran Avoian; Sean L Borkowski; Edward Ebramzadeh; Lewis E Zionts; Sophia N Sangiorgio
Journal:  J Child Orthop       Date:  2014-02-02       Impact factor: 1.548

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.