Literature DB >> 2917945

Calibration of respiratory inductive plethysmograph during natural breathing.

M A Sackner1, H Watson, A S Belsito, D Feinerman, M Suarez, G Gonzalez, F Bizousky, B Krieger.   

Abstract

We describe a single-posture method for deriving the proportionality constant (K) between rib cage (RC) and abdominal (AB) amplifiers of the respiratory inductive plethysmograph (RIP). Qualitative diagnostic calibration (QDC) is based on equations of the isovolume maneuver calibration (ISOCAL) and is carried out during a 5-min period of natural breathing without using mouthpiece or mask. In this situation, K approximates the ratio of standard deviations (SD) of the uncalibrated changes of AB-to-RC volume deflections. Validity of calibration was evaluated by 1) analyzing RIP waveforms during an isovolume maneuver and 2) comparing changes of tidal volume (VT) amplitude and functional residual capacity (FRC) level measured by spirometry (SP) with RIP values. Comparisons of VT(RIP) to VT(SP) were also obtained in a variety of postures during natural (uninstructed) preferential RC and AB breathing and with voluntary changes of VT amplitude and FRC level. VT(RIP)-to-VT(SP) comparisons were equal to or closer than published reports for single posture, ISOCAL, multiple- and linear-regression procedures. QDC of RIP in supine posture with comparisons to SP in that posture and others showed better accuracy in horizontal than upright postures.

Entities:  

Mesh:

Year:  1989        PMID: 2917945     DOI: 10.1152/jappl.1989.66.1.410

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  66 in total

1.  Accuracy and consistency of respiratory inductive plethysmography for overnight tidal volume measurement.

Authors:  J Zhang; E W Ruch; K E Bloch
Journal:  J Tongji Med Univ       Date:  2001

2.  Error analysis of a natural breathing calibration method for respiratory inductive plethysmography.

Authors:  N O Strömberg
Journal:  Med Biol Eng Comput       Date:  2001-05       Impact factor: 2.602

3.  Signal processing technique for non-invasive real-time estimation of cardiac output by inductance cardiography (thoracocardiography).

Authors:  G B Bucklar; V Kaplan; K E Bloch
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

Review 4.  Breathing pattern analysis.

Authors:  M J Tobin
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

Review 5.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Authors:  Roy J Shephard; Yukitoshi Aoyagi
Journal:  Eur J Appl Physiol       Date:  2011-12-11       Impact factor: 3.078

6.  Monitoring of breathing phases using a bioacoustic method in healthy awake subjects.

Authors:  Hisham Alshaer; Geoffrey R Fernie; T Douglas Bradley
Journal:  J Clin Monit Comput       Date:  2011-09-29       Impact factor: 2.502

7.  Danger of helmet continuous positive airway pressure during failure of fresh gas source supply.

Authors:  Nicolò Patroniti; Maurizio Saini; Alberto Zanella; Stefano Isgrò; Antonio Pesenti
Journal:  Intensive Care Med       Date:  2006-11-18       Impact factor: 17.440

8.  Breath-to-breath analysis of abdominal and rib cage motion in surfactant-depleted piglets during high-frequency oscillatory ventilation.

Authors:  Dick G Markhorst; Jos R C Jansen; Adrianus J van Vught; Huibert R van Genderingen
Journal:  Intensive Care Med       Date:  2005-01-20       Impact factor: 17.440

9.  Evaluating Risk Factors for Pediatric Post-extubation Upper Airway Obstruction Using a Physiology-based Tool.

Authors:  Robinder G Khemani; Justin Hotz; Rica Morzov; Rutger Flink; Asavari Kamerkar; Patrick A Ross; Christopher J L Newth
Journal:  Am J Respir Crit Care Med       Date:  2016-01-15       Impact factor: 21.405

10.  Increased vocal intensity due to the Lombard effect in speakers with Parkinson's disease: simultaneous laryngeal and respiratory strategies.

Authors:  Elaine T Stathopoulos; Jessica E Huber; Kelly Richardson; Jennifer Kamphaus; Devan DeCicco; Meghan Darling; Katrina Fulcher; Joan E Sussman
Journal:  J Commun Disord       Date:  2013-12-28       Impact factor: 2.288

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.