Literature DB >> 11465469

The design and implementation of COSEM, an iterative algorithm for fully 3-D listmode data.

R Levkovitz1, D Falikman, M Zibulevsky, A Ben-Tal, A Nemirovski.   

Abstract

In this paper,we present coincidence-list-ordered sets expectation-maximization (COSEM), an algorithm for iterative image reconstruction directly from list-mode coincidence acquisition data. The COSEM algorithm is based on the ordered sets EM algorithm for binned data but has several extensions that makes it suitable for rotating two planar detector tomographs. We develop the COSEM algorithm and extend it to include analytic calculation of detection probability, noise reducing iterative filtering schemes, and on-the-fly attenuation correction methods. We present an adaptation of COSEM to the Varicam\VG camera and show results from clinical and phantom studies.

Mesh:

Year:  2001        PMID: 11465469     DOI: 10.1109/42.932747

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  7 in total

1.  Towards continuous-to-continuous 3D imaging in the real world.

Authors:  L Caucci; Z Liu; A K Jha; H Han; L R Furenlid; H H Barrett
Journal:  Phys Med Biol       Date:  2019-09-18       Impact factor: 3.609

2.  Novel scatter compensation of list-mode PET data using spatial and energy dependent corrections.

Authors:  Bastien Guérin; Georges El Fakhri
Journal:  IEEE Trans Med Imaging       Date:  2010-11-29       Impact factor: 10.048

3.  LOR-OSEM: statistical PET reconstruction from raw line-of-response histograms.

Authors:  Dan J Kadrmas
Journal:  Phys Med Biol       Date:  2004-10-21       Impact factor: 3.609

4.  Objective assessment of image quality. V. Photon-counting detectors and list-mode data.

Authors:  Luca Caucci; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2012-06-01       Impact factor: 2.129

5.  Investigation of optimization-based reconstruction with an image-total-variation constraint in PET.

Authors:  Zheng Zhang; Jinghan Ye; Buxin Chen; Amy E Perkins; Sean Rose; Emil Y Sidky; Chien-Min Kao; Dan Xia; Chi-Hua Tung; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2016-07-25       Impact factor: 3.609

6.  A theoretical model for EM-ML reconstruction algorithms applied to rotating PET scanners.

Authors:  A Iriarte; C O S Sorzano; J M Carazo; J L Rubio; R Marabini
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

7.  Effects of shortened scanning intervals on calculated regional rates of cerebral protein synthesis determined with the L-[1-11C]leucine PET method.

Authors:  Giampaolo Tomasi; Mattia Veronese; Alessandra Bertoldo; Carolyn Beebe Smith; Kathleen C Schmidt
Journal:  PLoS One       Date:  2018-04-16       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.