Novel scatter compensation of list-mode PET data using spatial and energy dependent corrections.

Bastien Guérin1, Georges El Fakhri.   

Abstract

With the widespread use of positron emission tomography (PET) crystals with greatly improved energy resolution (e.g., 11.5% with LYSO as compared to 20% with BGO) and of list-mode acquisitions, the use of the energy of individual events in scatter correction schemes becomes feasible. We propose a novel scatter approach that incorporates the energy of individual photons in the scatter correction and reconstruction of list-mode PET data in addition to the spatial information presently used in clinical scanners. First, we rewrite the Poisson likelihood function of list-mode PET data including the energy distributions of primary and scatter coincidences and show that this expression yields an MLEM reconstruction algorithm containing both energy and spatial dependent corrections. To estimate the spatial distribution of scatter coincidences we use the single scatter simulation (SSS). Next, we derive two new formulae which allow estimation of the 2-D (coincidences) energy probability density functions (E-PDF) of primary and scatter coincidences from the 1-D (photons) E-PDFs associated with each photon. We also describe an accurate and robust object-specific method for estimating these 1-D E-PDFs based on a decomposition of the total energy spectra detected across the scanner into primary and scattered components. Finally, we show that the energy information can be used to accurately normalize the scatter sinogram to the data. We compared the performance of this novel scatter correction incorporating both the position and energy of detected coincidences to that of the traditional approach modeling only the spatial distribution of scatter coincidences in 3-D Monte Carlo simulations of a medium cylindrical phantom and a large, nonuniform NCAT phantom. Incorporating the energy information in the scatter correction decreased bias in the activity distribution estimation by ~20% and ~40% in the cold regions of the large NCAT phantom at energy resolutions 11.5% and 20% at 511 keV, respectively, compared to when using the spatial information alone.

Entities:  

Mesh:

Year:  2010        PMID: 21118770      PMCID: PMC3120772          DOI: 10.1109/TMI.2010.2095025

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  16 in total

1.  The design and implementation of COSEM, an iterative algorithm for fully 3-D listmode data.

Authors:  R Levkovitz; D Falikman; M Zibulevsky; A Ben-Tal; A Nemirovski
Journal:  IEEE Trans Med Imaging       Date:  2001-07       Impact factor: 10.048

2.  Scatter correction for positron emission mammography.

Authors:  Jinyi Qi; Ronald H Huesman
Journal:  Phys Med Biol       Date:  2002-08-07       Impact factor: 3.609

3.  Fast implementation of the single scatter simulation algorithm and its use in iterative image reconstruction of PET data.

Authors:  Alexander Werling; Olaf Bublitz; Josef Doll; Lars-Eric Adam; Gunnar Brix
Journal:  Phys Med Biol       Date:  2002-08-21       Impact factor: 3.609

Review 4.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

5.  Comparison of bootstrap resampling methods for 3-D PET imaging.

Authors:  C Lartizien; J-B Aubin; I Buvat
Journal:  IEEE Trans Med Imaging       Date:  2010-04-19       Impact factor: 10.048

6.  PET energy-based scatter estimation and image reconstruction with energy-dependent corrections.

Authors:  Lucreţiu M Popescu; Robert M Lewitt; Samuel Matej; Joel S Karp
Journal:  Phys Med Biol       Date:  2006-05-24       Impact factor: 3.609

7.  Resampling estimates of precision in emission tomography.

Authors:  D R Haynor; S D Woods
Journal:  IEEE Trans Med Imaging       Date:  1989       Impact factor: 10.048

8.  Realistic PET Monte Carlo Simulation With Pixelated Block Detectors, Light Sharing, Random Coincidences and Dead-Time Modeling.

Authors:  Bastein Guérin; Georges El Fakhri
Journal:  IEEE Trans Nucl Sci       Date:  2008       Impact factor: 1.679

9.  Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities.

Authors:  Suleman Surti; Austin Kuhn; Matthew E Werner; Amy E Perkins; Jeffrey Kolthammer; Joel S Karp
Journal:  J Nucl Med       Date:  2007-03       Impact factor: 10.057

10.  Optimization of a fully 3D single scatter simulation algorithm for 3D PET.

Authors:  Roberto Accorsi; Lars-Eric Adam; Matthew E Werner; Joel S Karp
Journal:  Phys Med Biol       Date:  2004-06-21       Impact factor: 3.609

View more
  4 in total

1.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  Objective assessment of image quality. V. Photon-counting detectors and list-mode data.

Authors:  Luca Caucci; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2012-06-01       Impact factor: 2.129

3.  Data-driven, energy-based method for estimation of scattered events in positron emission tomography.

Authors:  Nikos Efthimiou; Joel S Karp; Suleman Surti
Journal:  Phys Med Biol       Date:  2022-04-21       Impact factor: 4.174

4.  A LIST-MODE OSEM-BASED ATTENUATION AND SCATTER COMPENSATION METHOD FOR SPECT.

Authors:  Md Ashequr Rahman; Richard Laforest; Abhinav K Jha
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2020-05-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.