Does the combination of quantitative ultrasound and dual-energy X-ray absorptiometry improve fracture discrimination?

M L Frost1, G M Blake, I Fogelman.   

Abstract

The widespread availability of quantitative ultrasound (QUS) and X-ray absorptiometry densitometers raises the question of whether a combination of QUS and bone mineral density (BMD) measurements could provide a clinically useful method of enhancing the prediction of fracture risk. The aim of this study was to examine whether a combination of axial BMD and calcaneal QUS measurements can enhance fracture discrimination compared with either method alone. The study population consisted of 154 postmenopausal women with a history of atraumatic fracture at the spine, hip or forearm and 221 healthy postmenopausal women with no clinical risk factors for osteoporosis. Subjects had dual-energy X-ray absorptiometry (DXA) measurements of the lumbar spine (LS), femoral neck (FN) and total hip (THIP) and calcaneal broadband ultrasound attenuation (BUA) and speed of sound (SOS) measurements on the Hologic Sahara (SAH) and Osteometer DTUone (DTU). Z-scores were calculated using the mean and SD obtained from the healthy postmenopausal group. Logistic regression analysis yielded odds ratios for BMD measurements at the LS, FN and THIP of 2.2, 2.2 and 2.3, respectively. The odds ratios obtained for QUS measurements ranged from 2.5 for DTU BUA to 3.3 for SAH SOS. While these odds ratios for QUS measurements were higher than those obtained for BMD measurements, the differences were not statistically significant. When the odds ratios for QUS were adjusted for BMD at the spine and hip, the odds ratios remained significant in all cases indicating that QUS and BMD variables contribute independently to fracture discrimination. When the BMD-adjusted odds ratios were compared with those for QUS alone, they were slightly lower but not significantly so. When the QUS measurements were adjusted for THIP BMD, the odds ratios for QUS tended to be lower than when adjusted for LS and FN BMD. The Z-scores for each of the QUS measurement variables were combined with spine or hip Z-scores. Logistic regression analysis of the QUS and BMD combined Z-scores yielded slightly higher odds ratios of approximately 3.1 (compared with 2.9 obtained for QUS alone) and increases in the area under the curve of approximately 2%. However, these increases were not clinically significant. In conclusion, the combination of axial BMD and calcaneal QUS measurements did not significantly improve fracture discrimination compared with either method alone.

Entities:  

Mesh:

Year:  2001        PMID: 11446563     DOI: 10.1007/s001980170092

Source DB:  PubMed          Journal:  Osteoporos Int        ISSN: 0937-941X            Impact factor:   4.507


  8 in total

1.  Soy milk and dairy consumption is independently associated with ultrasound attenuation of the heel bone among postmenopausal women: the Adventist Health Study-2.

Authors:  Vichuda Lousuebsakul Matthews; Synnove F Knutsen; W Lawrence Beeson; Gary E Fraser
Journal:  Nutr Res       Date:  2011-10       Impact factor: 3.315

2.  Quantitative ultrasound and dual-energy X-ray absorptiometry in the prediction of fragility fracture in men.

Authors:  Stefano Gonnelli; Chiara Cepollaro; Luigi Gennari; Andrea Montagnani; Carla Caffarelli; Daniela Merlotti; Stefania Rossi; Alice Cadirni; Ranuccio Nuti
Journal:  Osteoporos Int       Date:  2004-12-14       Impact factor: 4.507

Review 3.  Clinical utilities of quantitative ultrasound in osteoporosis associated with inflammatory rheumatic diseases.

Authors:  Win Min Oo; Vasikaran Naganathan; Myat Thae Bo; David J Hunter
Journal:  Quant Imaging Med Surg       Date:  2018-02

4.  Quantitative Ultrasound (QUS) in the Management of Osteoporosis and Assessment of Fracture Risk: An Update.

Authors:  Didier Hans; Antoine Métrailler; Elena Gonzalez Rodriguez; Olivier Lamy; Enisa Shevroja
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 2.622

5.  Performance of calcaneus quantitative ultrasound and dual-energy X-ray absorptiometry in the discrimination of prevalent asymptomatic osteoporotic fractures in postmenopausal women.

Authors:  A El Maghraoui; F Morjane; A Mounach; M Ghazi; A Nouijai; L Achemlal; A Bezza; I Ghozlani
Journal:  Rheumatol Int       Date:  2008-10-25       Impact factor: 2.631

6.  Measurement of human trabecular bone by novel ultrasonic bone densitometry based on fast and slow waves.

Authors:  T Yamamoto; T Otani; H Hagino; H Katagiri; T Okano; I Mano; R Teshima
Journal:  Osteoporos Int       Date:  2008-11-07       Impact factor: 4.507

7.  Should age influence the choice of quantitative bone assessment technique in elderly women? The EPIDOS study.

Authors:  A M Schott; B Kassaï Koupaï; D Hans; P Dargent-Molina; R Ecochard; D C Bauer; G Bréart; P J Meunier
Journal:  Osteoporos Int       Date:  2004-01-17       Impact factor: 4.507

8.  Unique and common genetic effects between bone mineral density and calcaneal quantitative ultrasound measures: the Fels Longitudinal Study.

Authors:  M Lee; S A Czerwinski; A C Choh; E W Demerath; S S Sun; W C Chumlea; B Towne; R M Siervogel
Journal:  Osteoporos Int       Date:  2006-03-16       Impact factor: 4.507

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.