Endoscopic ultrasound-guided fine-needle aspiration in focal pancreatic lesions: a prospective intraindividual comparison of two needle assemblies.

A Fritscher-Ravens1, T Topalidis, C Bobrowski, C Krause, E Thonke, S Jäckle, N Soehendra.   

Abstract

BACKGROUND AND STUDY AIMS: The results of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in focal pancreatic lesions are less impressive than those in the mediastinum. The aim of this prospectively randomized study was to compare two commercially available needle assemblies with regard to handling and cytopathological yield. PATIENTS AND METHODS: A total of 30 patients (19 men, 11 women; mean age 61) with focal pancreatic lesions underwent EUS-FNA with each of the two needles (GIP, Wilson-Cook). The sequence was randomized for the examiner and blinded for the cytologist. Three patients had to be excluded because of the impossibility of sample assignment or patient follow-up. EUS-FNA was performed using the standard technique with linear echo endoscopes.
RESULTS: None of the characteristics evaluated by the examiner differed significantly between either of the needles. Inadequate results were obtained in 11% using the GIP needle, but in none with the Wilson-Cook needle. GIP needle cytology revealed malignancy in 11 patients (sensitivity, specificity, and accuracy were 55%, 100%, and 65%, respectively, including inadequate results). The aspirates obtained with the Wilson-Cook needle identified malignancy in 16 patients (sensitivity, specificity, and accuracy were 85%, 100%, and 89%, respectively).
CONCLUSIONS: No statistically significant differences were detected in the handling of either of the two needle assemblies. No complications were reported using the GIP needles. However, in four procedures breakages of the outer Teflon sheath of the Wilson-Cook needle occurred, and in another four cases re-insertion of the stylet was impossible. Nevertheless, cytopathologic results were significantly better with the Wilson-Cook needle.

Entities:  

Mesh:

Year:  2001        PMID: 11437040     DOI: 10.1055/s-2001-14970

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  17 in total

Review 1.  Endoscopic ultrasound-guided fine-needle aspiration in the diagnosis and staging of pancreatic adenocarcinoma.

Authors:  Kyung W Noh; Michael B Wallace
Journal:  MedGenMed       Date:  2005-05-25

2.  Endoscopic ultrasound-guided fine-needle aspiration for suspected malignancies adjacent to the gastrointestinal tract.

Authors:  Pietro Gambitta; Antonio Armellino; Edoardo Forti; Maurizio Vertemati; Paola Enrica Colombo; Paolo Aseni
Journal:  World J Gastroenterol       Date:  2014-07-14       Impact factor: 5.742

Review 3.  Rapid on-site evaluation increases endoscopic ultrasound-guided fine-needle aspiration adequacy for pancreatic lesions.

Authors:  Robert L Schmidt; Benjamin L Witt; Anna P Matynia; Gonzalo Barraza; Lester J Layfield; Douglas G Adler
Journal:  Dig Dis Sci       Date:  2012-10-04       Impact factor: 3.199

Review 4.  Endoscopic ultrasound guided fine needle tissue acquisition: where we stand in 2013?

Authors:  Zeid Karadsheh; Mohammad Al-Haddad
Journal:  World J Gastroenterol       Date:  2014-03-07       Impact factor: 5.742

5.  [Indications for pancreatic biopsy. Uncommon, but increasingly more important].

Authors:  J-M Löhr; G Klöppel
Journal:  Pathologe       Date:  2005-02       Impact factor: 1.011

6.  A comparative study of endoscopic ultrasound guided fine needle aspiration with and without a stylet.

Authors:  Sachin Wani; Neil Gupta; Srinivas Gaddam; Vikas Singh; Ozlem Ulusarac; Maria Romanas; Ajay Bansal; Prateek Sharma; Mojtaba S Olyaee; Amit Rastogi
Journal:  Dig Dis Sci       Date:  2011-02-17       Impact factor: 3.199

Review 7.  Imaging modalities for characterising focal pancreatic lesions.

Authors:  Lawrence Mj Best; Vishal Rawji; Stephen P Pereira; Brian R Davidson; Kurinchi Selvan Gurusamy
Journal:  Cochrane Database Syst Rev       Date:  2017-04-17

8.  A prospective comparison of EUS-guided FNA using 25-gauge and 22-gauge needles.

Authors:  Hiroo Imazu; Yujiro Uchiyama; Hiroshi Kakutani; Kei-Ichi Ikeda; Kazuki Sumiyama; Mitsuru Kaise; Salem Omar; Tiing Leong Ang; Hisao Tajiri
Journal:  Gastroenterol Res Pract       Date:  2009-11-17       Impact factor: 2.260

Review 9.  Pancreatico-biliary endoscopic ultrasound: a systematic review of the levels of evidence, performance and outcomes.

Authors:  Pietro Fusaroli; Dimitrios Kypraios; Giancarlo Caletti; Mohamad A Eloubeidi
Journal:  World J Gastroenterol       Date:  2012-08-28       Impact factor: 5.742

10.  Optimizing Diagnostic Yield for EUS-Guided Sampling of Solid Pancreatic Lesions: A Technical Review.

Authors:  Brian R Weston; Manoop S Bhutani
Journal:  Gastroenterol Hepatol (N Y)       Date:  2013-06