Literature DB >> 11369359

IFCC recommendation on reporting results for blood glucose.

R W Burnett, P D'Orazio, N Fogh-Andersen, K Kuwa, W R Külpmann, L Larsson, A Lewnstam, A H Maas, G Mager, U Spichiger-Keller.   

Abstract

In human beings, glucose is distributed like water between erythrocytes and plasma. The molality of glucose (amount of glucose per unit water mass) is the same throughout the sample. Different water concentrations in calibrator, plasma, and erythrocyte fluid can explain some differences that are dependent on sample type, methods requiring sample dilution, and direct reading biosensors detecting molality. Different devices for the measurement of glucose detect and report fundamentally different analytical quantities. The differences exceed the maximum allowable error of glucose determinations for diagnosing and monitoring diabetes mellitus, and they complicate the treatment. The goal of the International Federation of Clinical Chemistry, Scientific Division, Working Group on Selective Electrodes (IFCC-SD WGSE) is to reach a global consensus on reporting results. The document recommends harmonizing to the concentration of glucose in plasma (with the unit mmol/l), irrespective of sample type or technology. A constant factor of 1.11 will convert measured concentration in whole blood to the equivalent concentration in plasma.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11369359     DOI: 10.1016/s0009-8981(01)00431-4

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  22 in total

1.  The correlation of hemoglobin A1c to blood glucose.

Authors:  Ken Sikaris
Journal:  J Diabetes Sci Technol       Date:  2009-05-01

2.  Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus.

Authors:  David B Sacks; Mark Arnold; George L Bakris; David E Bruns; Andrea Rita Horvath; M Sue Kirkman; Ake Lernmark; Boyd E Metzger; David M Nathan
Journal:  Diabetes Care       Date:  2011-06       Impact factor: 19.112

3.  Evaluation of the analytical performance of the coulometry-based Optium Omega blood glucose meter.

Authors:  Bogdan Solnica; Beata Kusnierz-Cabala; Krystyna Slowinska-Solnica; Przemyslaw Witek; Agnieszka Cempa; Maciej T Malecki
Journal:  J Diabetes Sci Technol       Date:  2011-11-01

4.  Effects of Curcuma longa (turmeric) on postprandial plasma glucose and insulin in healthy subjects.

Authors:  Jennie Wickenberg; Sandra Lindstedt Ingemansson; Joanna Hlebowicz
Journal:  Nutr J       Date:  2010-10-12       Impact factor: 3.271

5.  Quality control of self-monitoring of blood glucose: why and how?

Authors:  Bogdan Solnica; Jerzy W Naskalski
Journal:  J Diabetes Sci Technol       Date:  2007-03

6.  Evaluation of the VIA Blood Chemistry Monitor for Glucose in Healthy and Diabetic Volunteers.

Authors:  Arjunan Ganesh; Brian Hipszer; Navdeep Loomba; Barbara Simon; Marc C Torjman; Jeffrey Joseph
Journal:  J Diabetes Sci Technol       Date:  2008-03

7.  Hypertension and low HDL cholesterol were associated with reduced kidney function across the age spectrum: a collaborative study.

Authors:  Michelle C Odden; Ira B Tager; Ron T Gansevoort; Stephan J L Bakker; Linda F Fried; Anne B Newman; Ronit Katz; Suzanne Satterfield; Tamara B Harris; Mark J Sarnak; David Siscovick; Michael G Shlipak
Journal:  Ann Epidemiol       Date:  2013-01-10       Impact factor: 3.797

8.  Age and cystatin C in healthy adults: a collaborative study.

Authors:  Michelle C Odden; Ira B Tager; Ron T Gansevoort; Stephan J L Bakker; Ronit Katz; Linda F Fried; Anne B Newman; Robert B Canada; Tamara Harris; Mark J Sarnak; David Siscovick; Michael G Shlipak
Journal:  Nephrol Dial Transplant       Date:  2009-09-11       Impact factor: 5.992

9.  Does green tea affect postprandial glucose, insulin and satiety in healthy subjects: a randomized controlled trial.

Authors:  Julija Josic; Anna Tholén Olsson; Jennie Wickeberg; Sandra Lindstedt; Joanna Hlebowicz
Journal:  Nutr J       Date:  2010-11-30       Impact factor: 3.271

10.  The Clinical Presentation of Puumala Hantavirus Induced Hemorrhagic Fever with Renal Syndrome Is Related to Plasma Glucose Concentration.

Authors:  Johanna Tietäväinen; Satu Mäkelä; Heini Huhtala; Ilkka H Pörsti; Tomas Strandin; Antti Vaheri; Jukka Mustonen
Journal:  Viruses       Date:  2021-06-20       Impact factor: 5.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.