Literature DB >> 11340879

High-resolution three-dimensional-pQCT images can be an adequate basis for in-vivo microFE analysis of bone.

W Pistoia1, B van Rietbergen, A Laib, P Rüegsegger.   

Abstract

Micro-finite element (microFE) models based on high-resolution images have enabled the calculation of elastic properties of trabecular bone in vitro. Recently, techniques have been developed to image trabecular bone structure in vivo, albeit at a lesser resolution. The present work studies the usefulness of such in-vivo images for microFE analyses, by comparing their microFE results to those of models based on high-resolution micro-CT (microCT) images. Fifteen specimens obtained from human femoral heads were imaged first with a 3D-pQCT scanner at 165 microns resolution and a second time with a microCT scanner at 56 microns resolution. A third set of images with a resolution of 165 microns was created by downscaling the microCT measurements. The microFE models were created directly from these images. Orthotropic elastic properties and the average tissue von Mises stress of the specimens were calculated from six FE-analyses per specimen. The results of the 165 microns models were compared to those of the 56 microns model, which was taken as the reference model. The results calculated from the pQCT-based models, correlated excellent with those calculated from the reference model for both moduli (R2 > 0.95) and for the average tissue von Mises stress (R2 > 0.83). Results calculated from the downscaled micro-CT models correlated even better with those of the reference models (R2 > 0.99 for the moduli and R2 > 0.96 for the average von Mises stress). In the case of the 3D-pQCT based models, however, the slopes of the regression lines were less than one and had to be corrected. The prediction of the Poisson's ratios was less accurate (R2 > 0.45 and R2 > 0.67) for the models based on 3D-pQCT and downscaled microCT images respectively). The fact that the results from the downscaled and original microCT images were nearly identical indicates that the need for a correction in the case of the 3D-pQCT measurements was not due to the voxel size of the images but due to a higher noise level and a lower contrast in these images, in combination with the application of a filtering procedure at 165 micron images. In summary: the results of microFE models based on in-vivo images of the 3D-pQCT can closely resemble those obtained from microFE models based on higher resolution microCT system.

Entities:  

Mesh:

Year:  2001        PMID: 11340879     DOI: 10.1115/1.1352734

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  21 in total

Review 1.  Bone quality: where do we go from here?

Authors:  Mary L Bouxsein
Journal:  Osteoporos Int       Date:  2003-08-29       Impact factor: 4.507

Review 2.  Methods for assessing bone quality: a review.

Authors:  Eve Donnelly
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

3.  Effects of idealized joint geometry on finite element predictions of cartilage contact stresses in the hip.

Authors:  Andrew E Anderson; Benjamin J Ellis; Steve A Maas; Jeffrey A Weiss
Journal:  J Biomech       Date:  2010-02-21       Impact factor: 2.712

4.  Finite element analysis of bone strength in osteogenesis imperfecta.

Authors:  Peter Varga; Bettina M Willie; Chris Stephan; Kenneth M Kozloff; Philippe K Zysset
Journal:  Bone       Date:  2020-01-22       Impact factor: 4.398

5.  Classification of trabeculae into three-dimensional rodlike and platelike structures via local inertial anisotropy.

Authors:  Branimir Vasilić; Chamith S Rajapakse; Felix W Wehrli
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

6.  Cortical porosity exhibits accelerated rate of change in peri- compared with post-menopausal women.

Authors:  L A Burt; J L Bhatla; D A Hanley; S K Boyd
Journal:  Osteoporos Int       Date:  2017-01-10       Impact factor: 4.507

7.  Suboptimal bone microarchitecure in adolescent girls with obesity compared to normal-weight controls and girls with anorexia nervosa.

Authors:  Vibha Singhal; Smriti Sanchita; Sonali Malhotra; Amita Bose; Landy Paola Torre Flores; Ruben Valera; Fatima Cody Stanford; Meghan Slattery; Jennifer Rosenblum; Mark A Goldstein; Melanie Schorr; Kathryn E Ackerman; Karen K Miller; Anne Klibanski; Miriam A Bredella; Madhusmita Misra
Journal:  Bone       Date:  2019-03-07       Impact factor: 4.398

8.  Impaired bone strength estimates at the distal tibia and its determinants in adolescents with anorexia nervosa.

Authors:  Vibha Singhal; Shreya Tulsiani; Karen Joanie Campoverde; Deborah M Mitchell; Meghan Slattery; Melanie Schorr; Karen K Miller; Miriam A Bredella; Madhusmita Misra; Anne Klibanski
Journal:  Bone       Date:  2017-07-08       Impact factor: 4.398

9.  Differences in Trabecular Plate and Rod Structure in Premenopausal Women Across the Weight Spectrum.

Authors:  Melanie Schorr; Pouneh K Fazeli; Katherine N Bachmann; Alexander T Faje; Erinne Meenaghan; Allison Kimball; Vibha Singhal; Seda Ebrahimi; Suzanne Gleysteen; Diane Mickley; Kamryn T Eddy; Madhusmita Misra; Anne Klibanski; Karen K Miller
Journal:  J Clin Endocrinol Metab       Date:  2019-10-01       Impact factor: 5.958

10.  Evaluation of angiogenesis using micro-computed tomography in a xenograft mouse model of lung cancer.

Authors:  Rajkumar Savai; Alexander Claus Langheinrich; Ralph Theo Schermuly; Soni Savai Pullamsetti; Rio Dumitrascu; Horst Traupe; Wigbert Stephan Rau; Werner Seeger; Friedrich Grimminger; Gamal Andre Banat
Journal:  Neoplasia       Date:  2009-01       Impact factor: 5.715

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.