Literature DB >> 11321291

Chip-based quantitative capillary electrophoresis/mass spectrometry determination of drugs in human plasma.

Y Deng1, H Zhang, J Henion.   

Abstract

A chip-based capillary electrophoresis/mass spectrometry (CE/MS) system is described for the on-chip separation and coupled electrospray detection of selected small drug molecule compounds. These studies include the quantitative determination of carnitine and acetylcarnitine in analytical standard solutions as well as imipramine and desipramine in fortified human plasma samples. A clinical human plasma sample was also analyzed following the normal administration of desipramine to a volunteer, and the parent drug was determined using the described chipbased CE/MS technique. In each instance, stable isotope-incorporated internal standards were used. The chip-based CE system was microfabricated from glass and coupled to a micro ion spray device constructed in-house. The atmospheric pressure ionization system employed in this work was a PE Sciex API III tandem triple quadrupole system operated in the selected ion monitoring (SIM) mode. The results from the work reported here demonstrate the feasibility for carrying out rapid (30 s) chipbased quantitative CE/MS determinations of samples containing small-molecule compounds. Using SIM CE/ MS techniques, the described API III quadrupole system provided acceptable ion current electropherograms from subpicomole levels of the targeted compounds loaded onto the chip. The corresponding electropherograms for the standard solution of carnitines at the 1-500 microg/mL level were obtained via SIM CE/MS techniques (R2 > 0.99). In addition, analyses of fortified samples of imipramine desipramine were measured relative to their corresponding d3 internal standards to obtain calibration curves ranging from 5 to 500 microg/mL in human plasma (R2 > 0.99). The intra-assay precision ranged from 4.1 to 7.3% RSD. The intra-assay accuracy ranged from 94.0 to 104%. These results demonstrate the feasibility for on-chip CE separation and electrospray mass spectrometric determination in applications for bioanalytical measurements for these important compounds in synthetic mixtures and human plasma extracts.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11321291     DOI: 10.1021/ac0010328

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  A systematic evaluation of chip-based nanoelectrospray parameters for rapid identification of proteins from a complex mixture.

Authors:  Ana Gabriela Pereira-Medrano; Alistair Sterling; Ambrosius P L Snijders; Kenneth F Reardon; Phillip C Wright
Journal:  J Am Soc Mass Spectrom       Date:  2007-06-30       Impact factor: 3.109

2.  Elastomeric microchip electrospray emitter for stable cone-jet mode operation in the nanoflow regime.

Authors:  Ryan T Kelly; Keqi Tang; Daniel Irimia; Mehmet Toner; Richard D Smith
Journal:  Anal Chem       Date:  2008-04-18       Impact factor: 6.986

3.  Evaluation of a microchip electrophoresis-mass spectrometry platform deploying a pressure-driven make-up flow.

Authors:  Xiangtang Li; Shulin Zhao; Yi-Ming Liu
Journal:  J Chromatogr A       Date:  2013-02-17       Impact factor: 4.759

Review 4.  Clinical pharmacokinetics of drugs used to treat urge incontinence.

Authors:  David R P Guay
Journal:  Clin Pharmacokinet       Date:  2003       Impact factor: 6.447

5.  Multi-Segment Direct Inject nano-ESI-LTQ-FT-ICR-MS/MS For Protein Identification.

Authors:  Jing Chen; Lorena Canales; Rachel E Neal
Journal:  Proteome Sci       Date:  2011-07-07       Impact factor: 2.480

6.  Graphene-based biomimetic materials targeting urine metabolite as potential cancer biomarker: application over different conductive materials for potentiometric transduction.

Authors:  Liliana A A N A Truta; Nádia S Ferreira; M Goreti F Sales
Journal:  Electrochim Acta       Date:  2014-12-20       Impact factor: 6.901

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.