Examination of the implant-abutment interface after fatigue testing.

R M Cibirka1, S K Nelson, B R Lang, F A Rueggeberg.   

Abstract

PURPOSE: This study examined potential differences in detorque values of abutment screws after fatigue testing when the dimensions between external implant hexagon and internal abutment hexagon were altered or the implant external hexagonal shape was eliminated.
MATERIAL AND METHODS: Three subsets (N = 10) of NobelBiocare implants were assessed: (1) standard external hexagon (R), (2) modified hexagon (M), and (3) circular (C) platform geometry. Thirty Procera machined abutments with 25-degree angulated loading platforms were manufactured. Abutments were retained with gold Unigrip abutment screws tightened to 32 N/cm with an electronic torque controller. Vertical scribes across the implant-abutment interface allowed longitudinal displacement evaluation. A carousel-type fatigue testing device delivered dynamic loading forces between 20 and 200 N for 5,000,000 cycles, or the approximate equivalent of 5 years in vivo mastication, through a piston to the abutment platform. Macroscopic and radiographic examination of the implant/abutment specimens was performed. The abutment screws were removed and the detorque values recorded. Bearing surfaces were examined microscopically.
RESULTS: No abutment looseness or longitudinal displacements at the implant-abutment interface were noted. Radiographic examination demonstrated no indication of screw bending or displacement. The mean detorque values for R, M, and C were 14.40 +/- 1.84 N/cm, 14.70 +/- 1.89 N/cm, and 16.40 +/- 2.17 N/cm, respectively. The analysis of variance demonstrated significant differences between only designs R and C (P=.031).
CONCLUSION: Increasing the vertical height, or degree of fit tolerance, between the implant external hexagon and the abutment internal hexagon or completely eliminating the implant external hexagon did not produce a significant effect on the detorque values of the abutment screws after 5,000,000 cycles in fatigue testing, or the equivalent of 5 years' of mastication for the implant/abutment specimens evaluated.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11264934     DOI: 10.1067/mpr.2001.114266

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  22 in total

1.  Influence of bone insertion level of the implant on the fracture strength of different connection designs: an in vitro study.

Authors:  Sergio Alexandre Gehrke; Miriam Souza Dos Santos Vianna; Berenice Anina Dedavid
Journal:  Clin Oral Investig       Date:  2013-07-17       Impact factor: 3.573

2.  Cad-cam procedure and implant-prosthetic rehaBilitation. Case report.

Authors:  F Guzzo; G DE Luca; P Barnaba; D Severino
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

3.  In vitro analysis of the microbiological sealing of tapered implants after mechanical cycling.

Authors:  Deceles Cristina Costa Alves; Paulo Sérgio Perri de Carvalho; Carlos Nelson Elias; Eduardo Vedovatto; Elizabeth Ferreira Martinez
Journal:  Clin Oral Investig       Date:  2016-02-20       Impact factor: 3.573

4.  Reliability and fatigue failure modes of implant-supported aluminum-oxide fixed dental prostheses.

Authors:  Christian F J Stappert; Marta Baldassarri; Yu Zhang; Felix Hänssler; Elizabeth D Rekow
Journal:  Clin Oral Implants Res       Date:  2011-09-05       Impact factor: 5.977

5.  Effect of framework type on survival probability of implant-supported temporary crowns: An in vitro study.

Authors:  Vinícius-Anéas Rodrigues; Amanda-Maria-de Oliveira Dal Piva; Claudio-Akira Yamaguchi; Alexandre-Luiz-Souto Borges; Marcio-Katsuyoshi Mukai; João-Paulo-Mendes Tribst
Journal:  J Clin Exp Dent       Date:  2020-05-01

6.  A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments.

Authors:  Ji-Man Park; Jai-Bong Lee; Seong-Joo Heo; Eun-Jin Park
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

7.  Stability of external and internal implant connections after a fatigue test.

Authors:  Paulo Cesar Pinheiro Feitosa; Ana Paula Barbosa de Lima; Laís Regiane Silva-Concílio; William Cunha Brandt; Ana Christina Claro Neves
Journal:  Eur J Dent       Date:  2013-07

8.  A rationale method for evaluating unscrewing torque values of prosthetic screws in dental implants.

Authors:  Felipe Miguel Saliba; Mayra Cardoso; Marcelo Ferreira Torres; Alexandre Carvalho Teixeira; Eduardo José Veras Lourenço; Daniel de Moraes Telles
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

9.  Influence of the implant abutment types and the dynamic loading on initial screw loosening.

Authors:  Eun-Sook Kim; Soo-Yeon Shin
Journal:  J Adv Prosthodont       Date:  2013-02-28       Impact factor: 1.904

10.  Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation.

Authors:  Matthias Rödiger; Sven Rinke; Fenja Ehret-Kleinau; Franziska Pohlmeyer; Katharina Lange; Ralf Bürgers; Nikolaus Gersdorff
Journal:  J Adv Prosthodont       Date:  2014-06-24       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.