Literature DB >> 11241713

Efficient off-resonance correction for spiral imaging.

K S Nayak1, C M Tsai, C H Meyer, D G Nishimura.   

Abstract

A new spiral imaging technique incorporates the acquisition of a field map into imaging interleaves. Variable density spiral trajectories are designed to oversample the central region of k-space, and interleaves are acquired at two different echo times. A field map is extracted from this data and multifrequency reconstruction is used to form an off-resonance corrected image using the entire dataset. Simulation, phantom, and in vivo results indicate that this technique can be used to achieve higher image and/or field map spatial resolution compared to conventional techniques. Magn Reson Med 45:521-524, 2001. Copyright 2001 Wiley-Liss, Inc.

Mesh:

Year:  2001        PMID: 11241713     DOI: 10.1002/1522-2594(200103)45:3<521::aid-mrm1069>3.0.co;2-6

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  Deblurring for spiral real-time MRI using convolutional neural networks.

Authors:  Yongwan Lim; Yannick Bliesener; Shrikanth Narayanan; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2020-07-25       Impact factor: 4.668

2.  Multi-frequency interpolation in spiral magnetic resonance fingerprinting for correction of off-resonance blurring.

Authors:  Jason Ostenson; Ryan K Robison; Nicholas R Zwart; E Brian Welch
Journal:  Magn Reson Imaging       Date:  2017-07-08       Impact factor: 2.546

3.  Dynamic off-resonance correction for spiral real-time MRI of speech.

Authors:  Yongwan Lim; Sajan Goud Lingala; Shrikanth S Narayanan; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2018-07-29       Impact factor: 4.668

4.  Application of k-space energy spectrum analysis for inherent and dynamic B0 mapping and deblurring in spiral imaging.

Authors:  Trong-Kha Truong; Nan-Kuei Chen; Allen W Song
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

5.  Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T with radial EPI.

Authors:  Himanshu Bhat; Qi Yang; Sven Zuehlsdorff; Kuncheng Li; Debiao Li
Journal:  Magn Reson Med       Date:  2011-02-08       Impact factor: 4.668

6.  Phase-contrast velocimetry with simultaneous fat/water separation.

Authors:  Kevin M Johnson; Oliver Wieben; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2010-06       Impact factor: 4.668

7.  Regularized field map estimation in MRI.

Authors:  Amanda K Funai; Jeffrey A Fessler; Desmond T B Yeo; Valur T Olafsson; Douglas C Noll
Journal:  IEEE Trans Med Imaging       Date:  2008-10       Impact factor: 10.048

8.  Template-based field map prediction for rapid whole brain B0 shimming.

Authors:  Yuhang Shi; S Johanna Vannesjo; Karla L Miller; Stuart Clare
Journal:  Magn Reson Med       Date:  2017-11-28       Impact factor: 4.668

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.